Autocall A4090-9121 Security Monitor IAM (Individual Addressable Module)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-a4090-9121-security-monitor-iam-individual-addressable-module-0813652497.pdf |
---|---|
Type | |
Size | 990.76 KB |
Downloads |
Text Preview
Datasheet Peripherals Security Monitor IAM Individual Addressable Module ULC CSFM Listed FM use with Autocall 4100ES 4100U and 4010ES Fire Alarm Panels providing IDNet communications communications supply both data and power over a wire pair to provide Supervised Class B monitoring of normally closed or normally open dry security devices Monitored conditions are Open Normal Abnormal and Short Abnormal occurs with of monitor loop current change Total wiring distance from Security iam to supervised contacts up to ft 152 m sealed construction Enclosed design minimizes dust infiltration Mounts in a standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after requires mounting bracket ordered separately listed to Standard 1076 Monitor IAM model A4090 9121 has both power and supplied by a two wire 4100ES 4100U or 4010ES IDNet It provides location specific addressability for up to five initiating such as window or door magnet switch contacts or other similar devices by monitoring the circuit wiring connections to either closed or normally open dry contacts one type per IAM the circuit is armed by selection from the fire alarm control such as during nonworking hours monitor loop activity short or abnormal causes a priority 2 alarm at the panel the circuit is disarmed such as during normal working hours and abnormal conditions would be tracked as events Depending the point type selected an open or short in the monitored circuit will cause a trouble to be reported or a short can be tracked as an 1 Security Monitor shown approximately full size Selection Monitor IAM mount mount trim plate with LED viewing requires A4090 9810 bracket includes mounting galvanized steel Mounting bracket mounts IAM to box provides screw for trim plate required for optional trim plates k Resistor Harness use for series connection to N O k Resistor Harness use for series and end of line when connected to N C switches 2 required This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7300 2269 0506 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 8 03 2021 Security Monitor IAM Individual Addressable Module other devices on the channel IDNet one address two 2 unit loads power is supplied from the IDNet SLC signaling line circuit max on a 64 pt channel max on a 127 pt channel max on a 250 pt channel contacts up to 5 in series for normally closed N C or up to 5 in parallel for normally open N O two resistor harnesses per wiring type selected see above terminals for in out wiring 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 ft 152 m maximum within same building ft 762 m max distance from control panel ft 3048 m maximum total wiring distance including T Taps W x 1 3 4 H x 1 1 4 D 40 mm x 44 mm x 32 mm thermoplastic to 120 F 0 to 49 C indoor operation only to 93 RH at 100 F 38 C to Installation Instruction 574 877AC Requirements Channel Loading Reference Communications Distance Contacts Connections to Contacts Material Range Information Information A4090 9121 Security IAM shown in Figure 2 2 Reference Single Gang Blank Cover Plate 2 Rev 8 03 2021 Security Monitor IAM Individual Addressable Module 3 Trim Plates and Mounting Bracket for Visible LED The following products are illustrated in Figure 3 A4090 9806 trim plate for semi flush mounted box A4090 9807 trim plate for surface mounted box A4090 9810 mounting bracket ordered separately These mounting plates require mounting bracket A4090 9810 3 Rev 8 03 2021 Security Monitor IAM Individual Addressable Module 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 8 03 2021