Autocall A4098-9846 Sensor Guard for TrueAlarm Sensors

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC listed FM Approved Autocall TrueAlarm sensors and bases ordered A4098 9714 Photoelectric sensor A4098 9754 Multi Sensor Photoelectric and Heat A4098 9733 Heat Sensor A4098 9792 Standard Sensor Base A4098 9791 Relay Control Base A4098 9789 LED Output Base A4098 9793 IDNet Isolator Base features For ceiling or wall mounted sensor applications Combines accurate individually addressable analog smoke and or heat with physical protection TrueAlarm analog sensing provides compensation for air flow by providing maintained high sensitivity Photoelectric smoke sensitivity is selectable from 0.5 ft to 1.5 ft at fire alarm control unit The host control unit automatically compensates for sensitivity shifts by contamination and automatically reports dirty devices UL listed to Standard 268 URRQ and 521 UQKE ULC listed to Standard 529 URRQC and 530 UQKEC options Standard mounting of A4098 9846 is for use with flush mounted boxes electrical box Extension box A4098 9847 is required for mounting to surface resistant design Heavy duty steel construction single wall Tamper resistant grill mounting screws Guard A4098 9846 the sensitivity and maintained accuracy of Autocall TrueAlarm with a rugged tamper resistant enclosure Typical applications correctional and detention facilities mental hospitals industrial educational facilities dormitories and many other locations the smoke sensor may be intentionally or accidentally subjected abuse Reference this combination the sensor can be located directly in the ceiling a detention cell or similar area and can provide accurate and quick of smoke and or heat conditions Additionally after removing tamper resistant hardware the sensor is readily accessible for when the TrueAlarm system automatically identifies the need maintenance Sensors Sensor Guard for TrueAlarm Sensors 1 TrueAlarm Sensor Guard Reference ceiling mount shown with optional mount extension see page 2 for details Rev 2 03 2021 material pattern or finish frame hardware mounting screws Sensors and Bases A4098 9754 IDNet Isolator Base Sensor Guard for TrueAlarm Sensors 1 General specifications in 165 mm x 6 in 165 mm x 3 in 76 mm wall construction 22 gauge steel 0.025 in thick 0.64 mm in 6.4 mm hex holes staggered on in 6.4 mm centers reinforced at corners baked enamel in tamper resistant screws recessed hex head supplied with guard 2 Additional Reference Sheet Information Important See Warning and Installation Notes Below Adapter Plate Possible sensor bases A4098 9789 A4098 9791 A4098 9792 or A4098 9793 with A4098 9846 A4098 9847 Extension Box 2 reference 2 Rev 2 03 2021 Sensor Guard for TrueAlarm Sensors NFPA 72 the National Fire Alarm and Signaling Code Section 5.4.3 2007 Edition Where subject to mechanical damage an initiating device be protected A mechanical guard used to protect a smoke heat or radiant energy detector shall be listed for use with the detector guard A4098 9846 is for use only with a Autocall A4098 9714 Photoelectric Sensor or a A4098 9754 Photo Heat Sensor with a restricted range of 0.5 to 1.5 per foot obscuration or with a A4098 9733 Heat Sensor and for use only with sensor bases A4098 9789 A4098 9791 or A4098 9793 This will ensure the sensor will activate within the UL listed obscuration range when mounted in the sensor guard Note For proper performance follow installation instructions and review sensor and guard locations carefully Wall mounting may not be for institutional or detention applications Issue The presence of debris on the sensor guard grill will significantly restrict airflow into the sensor It is recommended that visual maintenance be performed to ensure proper operation Notes For additional information refer to Installation Instructions 579 116AC Ceiling mount is shown above for reference if appropriate installations can be wall mounted Flush mounted electrical box must be flush to surface or recessed no more than 1 4 in 6.4 mm Select box depth to accommodate selected base For surface electrical box mounting only Extension Box A4098 9847 and Adapter Plate A4098 9832 are both required ordered separately Electrical Installation to wall or ceiling requires solid anchoring use 1 4 in bolts by others Hardware is included with the A4098 9847 Extension Box for must be 1 in deep the sensor guard frame Do not use Extension Box A4098 9847 with flush mounted electrical boxes sensor will not be properly positioned 3 Rev 2 03 2021 Sensor Guard for TrueAlarm Sensors 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 2 03 2021

Related Files