Autocall A4098-9846 TrueAlarm® Sensor Vandal Guard Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

A4098 9846 TrueAlarm Sensor Vandal Guard Installation Instructions Warnings and Regulatory Information AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation manual These instructions must be followed to avoid damage to product and associated equipment Product operation and reliability depend upon proper installation NOT INSTALL ANY AUTOCALL PRODUCT THAT APPEARS DAMAGED Upon unpacking your Autocall product inspect the of the carton for shipping damage If damage is apparent immediately file a claim with the carrier and notify an authorized product supplier HAZARD Disconnect electrical field power when making any internal adjustments or repairs All repairs should be by a representative or an authorized agent of your local Autocall product supplier This product is designed to protect a smoke sensor from vandalism It is not designed to protect people from intentionally harm to themselves Please use caution when installing this device in detention facilities hospitals or other residential or highly locations Information NFPA Section 2 1.3.1 1999 Edition subject to mechanical damage an initiating device shall be protected A mechanical guard used to a smoke or heat detector shall be listed for use with the detector being used presence of debris on the sensor vandal guard will significantly restrict airflow into the sensor It is recommended that increased visual be performed to ensure proper operation publication shows how to install the A4098 9846 TrueAlarm Sensor Vandal Guard The sensor guard is a device that is mounted on a wall or to provide protection for a A4098 9714 Smoke Sensor a A4098 9733 Heat Sensor or a A4098 9754 Photo Heat Sensor Use only a A4098 9714 Sensor a A4098 9733 Heat Sensor or a A4098 9754 Photo Heat Sensor Refer to 2120 Job Configuration Report or Custom Control Equation Listing in the 4010 4020 or 4100 Programmer Report to verify sensitivity range is between 0.5 to 1.5 per foot obscuration procedure Seal the electrical box using 3M Weatherban 606 or equivalent Use the appropriate template to drill holes for appropriate anchoring per local building codes Use Figure 2 if you are flush mounting with the mounting frame Use Figure 3 if you are surface mounting with the A4098 9847 Extension Box the sensor and base The installed sensor base must be a A4098 9789 A4098 9791 A4098 9792 or A4098 9793 A4098 9777 A4098 9766 A4098 9767 Refer to A4098 Smoke Heat Sensor Bases Installation Instructions 574 707AC when installing sensor bases the sensor guard mounting frame to the wall or ceiling using 1 4 inch minimum diameter hex head bolts with lead expansion or toggle bolts not supplied Avoid plastic shields Mount Electrical Box Mount Electrical Box the A4098 9847 Extension Box to the wall or ceiling using 1 4 inch minimum diameter hex head bolts with lead expansion or toggle bolts not supplied Avoid plastic shields the sensor guard mounting frame to the extension box using 1 4 inch diameter hex head bolts not supplied Place the sensor guard cover in the mounting frame Secure the cover to the frame using four 10 32 x 1 2 inch long button head hex with center pin screws supplied DO NOT paint the sensor guard Rev C TrueAlarm Sensor Vandal Guard Installation Instructions 1 Installing the Sensor Guard with a A4098 9789 A4098 9791 or A4098 9793 A4098 9777 A4098 9766 A4098 9767 sensor base shows A4098 9847 1 inch extension box shows a A4098 9714 sensor with a A4098 9789 A4098 9791 A4098 9792 or A4098 9793 A4098 9777 A4098 9766 A4098 9767 base and Testing recommends routine cleaning of the smoke sensor and guard so that dust and other matter does not accumulate Refer to the A4098 Sensors and Bases Application Manual 574 709AC for details The strength of final installation requires heavy solid anchoring The flush mounted electrical box must be installed even to the surface or recessed 1 4 inch maximum If the electrical box is surface mounted the A4098 9847 Extension Box must be used the figures on the next pages as templates when you are mounting the sensor guard Use Figure 2 for flush mount applications Use Figure 3 for surface mount applications 2 Rev C TrueAlarm Sensor Vandal Guard Installation Instructions Do not photocopy this figure Use the original figure as a template 2 Sensor Guard Mounting Frame Template Flush Mounting 3 Rev C Do not photocopy this figure Use the original figure as a template 3 A4098 9847 Extension Box Mounting Template Surface Mounting 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice Additional listings may be applicable contact your local Autocall supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Alarm Code are registered trademarks of the National Fire Protection Association NFPA Rev C

Related Files