Autocall A4606-9101 LCD Annunciator for 4006 Fire Alarm Control Panels
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-a4606-9101-lcd-annunciator-for-4006-fire-alarm-control-panels-3961054287.pdf |
---|---|
Type | |
Size | 1.69 MB |
Downloads |
Text Preview
Datasheet Accessories LCD Annunciators LCD Annunciator for 4006 Fire Alarm Control Panels 1 LCD Annunciator Scrolling operation of the appropriate acknowledge switch will scroll LCD display showing activity in the sequence of occurrence The tone alert also sounds to indicate the operation of any of the switches Access All switches on the annunciator are controlled by ENABLE keyswitch with a key that is removable only in the disabled Operations When enabled notification appliances can be by pressing the ALARM SILENCE switch Pressing the RESET switch restores the system to normal operation When activity is normal the LCD displays the time date and SYSTEM NORMAL ULC CSFM Listed FM LCD annunciator for use with Autocall model 4006 fire control panels readout provides Two lines of 40 characters each Wide viewing angle super twist design LED backlighting switches and status LEDs for Alarm supervisory or trouble acknowledge keyswitch access Alarm silence System reset programmable LED indicators Two LEDs are selectable as red or yellow One LED is selectable as green or yellow With provisions for custom labeling features Information is transmitted over a single twisted shielded pair separate is required for 24 VDC control panel power Tone alert sounder provides local audible indication Lamp and LCD are functionally tested each time the keyswitch is on Mounts flush on standard 6 gang electrical box and trim options Surface mount box model 2975 9206 ordered separately see LCD Annunciator Specifications Brushed stainless steel trim model A4603 9111 ordered separately Annunciation LCD Annunciators allow compatible fire alarm control to provide information and control switches at convenient away from the control panel The LCD is an 80 character alphanumeric display with information presented in clear and English Typical content includes point status alarm trouble alarm type smoke detector manual station etc number of alarms supervisory conditions troubles and custom location up to 40 characters long Some 4006 messages are limited to characters refer to the control panel documentation for additional communications require a single twisted shielded pair that other annunciators on the same communications channel 4006 Series panels control up to four annunciators Supervisory and Trouble conditions are also indicated by LEDs and a tone alert audible indication Each condition has a acknowledge push button switch that silences the tone alert leaves the LED on until all conditions in that category are restored to This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0569 7300 2269 0567 and 7300 0026 0381 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local supplier for the latest status Rev 10 03 2021 LCD Annunciator for 4006 Fire Alarm Control Panels Selection 1 Product Selection LCD Annunciator with beige trim stainless steel trim option surface mount box ivory finish matching resistor harness 100 1 2 W reference no 733 974 protector required where annunciator communications and power wiring exits and enters a building refer to data AC2081 0016 for details to A4606 9101 LCD Annunciator for additional details LCD Annunciator Specifications 2 General Operating Specifications refer to Installation Instructions 579 978AC for additional information Operating Current Standby Current Current Temperature Range Humidity Range to 32 VDC system supplied mA with LED backlighting on mA during battery backup LED backlighting is turned off after 30 seconds without switch activity mA maximum LED backlighting is on and tone alert is sounding to 120 F 0 to 49 C to 93 RH non condensing at 100 F 38 C 3 Communications 4006 Panels Requirements Matching Resistor and Earth wiring wiring wiring wiring communications format but with different capacity to 4 annunciator modules total compatible with A4606 9101 A4610 9111 and door mounted LED twisted shielded pair 18 AWG 0.82 mm2 to 12 AWG 0.82 mm2 to 3.31 mm2 wires for 24 VDC system power and Earth ground for electrical ground per local code to 4000 ft 1219 m 0.58 580 nF maximum capacitance 35 maximum resistance to 10,000 ft 3048 m total wiring up to 2500 ft 762 m to farthest device one at panel and one at end of line one at panel and one at farthest device 1 2 W PID A4081 9011 part 733 974 Dimensions Depth Trim Finish Optional Trim for Flush supplied others boxes gang boxes selection note 4 Mounting Information H x 11 13 16 W 114 mm x 300 mm 5 16 33 mm 1 at terminal block location 38 mm painted beige stainless steel ordered separately supplied with both slotted and tamper resistant screws box Steel City GW 635 G 3 89 mm deep or equal single gang boxes 3 89 mm deep minimum RACO 590 or equal entrance is box dependent refer to additional mounting information on page 4 and Instructions 579 978AC 5 2975 9206 Surface Mount Box Option ordered separately Refer to control panel data sheets AC4010 0001 AC4006 0001 for additional information 31 32 W x 4 H x 2 D 304 mm x 117 mm x 70 mm steel ivory finish 2 Rev 10 03 2021 Operator Information LCD Annunciator for 4006 Fire Alarm Control Panels Information 2 Operator Information Surface mount box illustrated is 2975 9206 3 Information 3 Rev 10 03 2021 Reference LCD Annunciator for 4006 Fire Alarm Control Panels 4 Reference A4606 9101 LCD Annunciators is shown Wiring Notes Communications require a single 18 AWG twisted shielded pair Power requires two 18 to 12 AWG wires for 24 VDC system power plus Earth Ground to each electrical box Refer to Installation Instructions 579 978AC for additional information 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 10 03 2021