Autocall A4606-9102 LCD Annunciator for 4010ES Fire Alarm Control Panels

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Accessories LCD Annunciators LCD Annunciator for 4010ES Fire Alarm Control Panels 1 LCD Annunciator Access All switches on the annunciator are controlled by ENABLE keyswitch with a key that is removable only in the disabled A brief Lamp LCD test is performed whenever the keyswitch is from enabled to disabled Operations When enabled notification appliances can be by pressing the ALARM SILENCE switch Pressing the RESET switch restores the system to normal operation When activity is normal the LCD displays the time date and SYSTEM NORMAL ULC CSFM Listed FM LCD annunciator for use with Autocall model 4010ES fire control panels readout provides Two lines of 40 characters each Wide viewing angle super twist design LED backlighting switches and status LEDs for Alarm Priority 2 Supervisory or Trouble acknowledge keyswitch controlled Alarm silence System reset Three programmable control switches with yellow LEDs and provisions custom labeling features Information is transmitted over a single unshielded twisted pair wiring is required for 24 VDC control panel power see LCD Annunciator Specifications for more information Tone alert sounder provides local audible indication Lamp and LCD are functionally tested each time the keyswitch is on Mounts flush on standard 6 gang electrical box Up to up to 20 internal and external card addresses per 4010ES fire control panel and trim options ordered separately see Table 4 for details Surface mount box model 2975 9206 Brushed stainless steel trim model A4603 9111 Annunciation LCD Annunciator allows 4010ES fire alarm control to provide information and control switches at convenient away from the control panel The LCD is an 80 character alphanumeric display with information presented in clear and English Typical content includes point status alarm trouble alarm type smoke detector manual station etc number of alarms supervisory conditions troubles and custom location up to 40 characters long communications require a single unshielded twisted pair that other annunciators on the same communications channel Priority 2 Supervisory and Trouble conditions are also indicated dedicated LEDs and a tone alert audible indication Each condition a dedicated acknowledge push button switch that silences the but leaves the LED on until all conditions in that category are to normal Scrolling operation of the appropriate acknowledge switch will scroll LCD display showing activity in the sequence of occurrence The tone alert also sounds to indicate the operation of any of the switches This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0569 7300 2269 0557 7300 2269 0567 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest Rev 9 03 2021 LCD Annunciator for 4010ES Fire Alarm Control Panels Selection LCD Annunciator with beige trim for use with 4010ES fire alarm control stainless steel trim option to A4606 9102 LCD Annunciator for additional details surface mount box ivory finish protector required where annunciator communications and power wiring exits and enters a building refer to data AC2081 0016 for details Operator Information 2 Rev 9 03 2021 LCD Annunciator for 4010ES Fire Alarm Control Panels LCD Annunciator Specifications 1 General Operating Specifications refer to Installation Instructions 579 977AC for additional information Operating Current Standby Current Current Temperature Range Humidity Range 4010ES Panels Wiring Type Characteristics Applications Shielded Pair STP B T Tap wiring X wiring distance Data Wiring Wiring to 32 VDC system supplied mA with LED backlighting on mA during battery backup LED backlighting is turned off after 30 seconds without switch activity mA maximum LED backlighting is on and tone alert is sounding to 120 F 0 to 49 C to 93 RH non condensing at 100 F 38 C 2 Communications Remote Unit Interface external annunciator communications line SLC signaling line circuit to 20 total internal and external card addresses 3 Wiring Requirements twisted pair UTP 18 AWG 0.82 mm2 for most applications see below 580 nF maximum capacitance between conductors 35 maximum total line resistance that leaves the building Also requires Isolated Loop Circuit Protectors on each end refer to data AC2081 0007 for A2081 9027 200 mA or S2081 0008 for A2081 9028 5 A run in 500 ft 152 m or more of conduit closely bundled with standard IDNet communications or TrueAlert addressable communications required when run with IDNet communications to 10,000 ft 3048 m total wiring up to 2500 ft 762 m to farthest device to 2500 ft 762 m to 12 AWG 0.82 mm2 to 3.31 mm2 wires for 24 VDC system power dedicated earth ground connection to the electrical box is required for proper ESD and EMI protection in accordance with NFPA 70 National Electrical Code Article 250 4 Mounting Information Dimensions Depth Trim Finish Optional Trim for Flush Surface Mount Box Option ordered separately boxes gang boxes selection note H x 11 13 16 W 114 mm x 300 mm 5 16 33 mm 1 at terminal block location 38 mm painted beige stainless steel ordered separately supplied with both slotted and tamper resistant screws box Steel City GW 635 G 3 89 mm deep or equal single gang boxes 3 89 mm deep minimum RACO 590 or equal entrance is box dependent refer to Installation Instructions 579 977AC for additional mounting and conduit entry requirements W x 4 H x 2 D 305 mm x 117 mm x 70 mm steel ivory finish Refer to the 4010ES control panel data sheet for additional panel information 3 Rev 9 03 2021 Information LCD Annunciator for 4010ES Fire Alarm Control Panels Reference Wiring Notes Communications require 18 to 12 AWG unshielded twisted pair Power requires two 18 to 12 AWG wires for 24 VDC system power plus Earth Ground to each electrical box Refer to Installation Instructions 579 977AC for additional wiring specifications 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 9 03 2021

Related Files