Autocall A4905-9996CA Insuite Device Distribution Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-a4905-9996ca-insuite-device-distribution-module-7152638094.pdf |
---|---|
Type | |
Size | 716.75 KB |
Downloads |
Text Preview
Notification Appliances Insuite Device Distribution Module 1 General specifications VDC Regulated mA VRMS mA Voltage Current Voltage Current of Insuite Silence Devices Per Module of Distribution Modules Fire Alarm NAC Load Per Suite Box Requirements Dimensions Connections Watts 25 VRMS or 80 mA 24 11 square box 2 1 8 deep 1 1 2 extension ring 15 16 square terminals for input and wiring 18 to 14 AWG wire mm to 2.08 mm Approved Supports Supervised Operation Provides short circuit isolation Support for 24 VDC or 25 VAC NACs Fully compatible with standard non Insuite dedicated NACs Style Z Class B NAC compatibility Compatible with A4901 Series Insuite Silenceable Devices refer to data AC4901 0015 for additional information For surface mounting in a 4 11 electrical box cover is included A4905 9996CA Insuite Device Distribution Module is an integral of providing a robust and cost effective solution to meet audible requirements for dwelling units as specified in various building unit is designed to comply with requirements that ensure any with insuite devices including open circuit grounded circuit short circuit will not affect the operation of any other devices located other suites A4905 9996CA accepts input from a Fire Alarm NAC connects to A4901 Series Insuite Silenceable devices located in the suites has an output back to the Fire Alarm NAC The A4905 9996CA is field mounted as they are housed in 4 11 16 square electrical Depending upon which building code compliance is required the device circuits are run from the A4905 9996CA in either Class Class configurations A4905 9996CA connects to a 24 VDC or 25V Audio NAC and full supervision beyond the distribution module 1 Insuite Device Module Installation Reference Box and extension ring are supplied separately Additional listings may be applicable contact your local product supplier for the latest status Rev 2 6 2019 diagrams Insuite Device Distribution Module 2 Audio Application Using Distribution and Insuite Silence Modules Class B Supervision reference A4905 9996CA B A4901 9839CA 3 Application Using Distribution and Insuite Silence Modules Class B Supervision reference A4905 9996CA A4901 9839CA B A4901 9839CA When the A4901 9839CA silence switch is used in conjunction with slave speakers this 24 VDC power source provided by the Fire Alarm Control must be interrupted during use of the fire alarm microphone This diagram provides an applications overview not all wiring is shown The A4905 9996CA does not accept an input from a 70V Audio NAC 2019 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 2 6 2019