Autocall AC4100-1038 Remote Annunciator Panels
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-ac4100-1038-remote-annunciator-panels-3648752109.pdf |
---|---|
Type | |
Size | 12.88 MB |
Downloads |
Text Preview
UL ULC CSFM Listed Approved OTCR NYC Annunciator Panels provide fire alarm control panel information at locations distant from the fire alarm panel functions include Remote status LED indicators and dedicated switch input controls on LED switch modules Remote status LED indicator modules with 8 red or 16 8 red 8 yellow that are pluggable to allow color selection yellow green or red are ordered separately Remote microphone and operator interface for access to the voice alarm communications system Remote master telephone for communicating to the firefighter system Also available with InfoAlarm Command Center expanded content interface refer to Two Bay Remote Annunciator LED Switch Reference InfoAlarm Command Center Detail Reference and datasheet AC4100 1045 for additional information optional modules include Remote Command Center module for LCD status readout and controlled functions 24 Point I O module RS 232 ports for remote printer or terminal connections Power supplies with battery charger for annunciator Panel mounted printer for system status recording requirements RUI or RUI remote unit interface supervised communications the host fire alarm control panel provide Class B or Class X SLC line circuit pathway connections Microphone and telephone circuits require their own dedicated wiring to UL 864 Fire Detection and Control UOJZ Smoke Control Service Releasing Device Service SYZV Emergency Communication Relocation Equipment UOQY Control Unit Accessories UOXX UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Service SYZV7 Control Unit Accessories UOXX7 CAN ULC S559 Central Station Fire Alarm System Units DAYR7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 Fire Control Units Annunciator Panels 1 Remote Annunciator in a Three Bay with Audio Operator Modules Remote Command left and with an InfoAlarm Command Center right Annunciator Panels Annunciator Panels are dedicated purpose transponders that fire alarm system status information Typical use is when the fire alarm control panel is located away from the area where those to a fire situation need status information and Control are suitable for firefighter or other fire brigade responders to particular information and for system control When equipped a remote microphone and emergency voice alarm communications control an authorized user can take command of the system either play selected pre recorded messages or select specific tones initiate live broadcast information either globally into the system or to areas Master Firefighter Phone equipped with a remote master phone the authorized user connect to remote phone call in requests and allow callers to be to each other Although intended for use in assisting fire these system are also helpful during system setup and test listings may be applicable contact your local Autocall product supplier for the latest status Rev 2 03 2020 Annunciator Panels Bay Description Annunciators annunciators include a bay assembly a power distribution interface module PDI a Transponder Interface Module and an interconnect Communications with the host fire alarm control panel are via a Remote Unit Interface RUI or RUI connection that allows for up to 2500 762 m distance RUI can communicate with up to a total of 31 remote devices per master controller on one or multiple RUI channels and can be as a Class B or Class X communication pathway Wiring can be either shielded or unshielded twisted or untwisted single pair wiring Remote Annunciator model is for applications that may require a full complement of the Remote Annunciator functions see Product Selection Power is from a cabinet Remote Power Supply RPS Basic Remote Annunciator remote annunciator applications that require less features in the cabinet select this model which accepts power from a separate fire alarm control This model does NOT accept a cabinet mounted power supply expansion phone cards Class A phone modules RS 232 modules panel printers or 24 I O modules Expansion Bays includes a PDI and accept a variety of optional modules for specific annunciator functions Battery Compartment battery compartment bottom accepts two batteries up to 50 Ah Battery mounting does not interfere with available module space Not to the model A100 9611 Availability Modules are power limited except as noted such as relay modules Enclosure are available for one two or three bay sizes or for cabinet rack mounting Boxes doors with tempered glass inserts and dress panels are available in beige or red ordered separately Refer to document AC4100 0037 for enclosure details Command Center optional Remote Command Center occupies the top bay of a Remote Annunciator It provides an LCD status readout with keyswitch activated switches and a local tone alert sounder Features are essentially identical to the Remote LCD Annunciator model A4603 9101 reference AC4603 0001 2 Remote Command Center 2 Rev 2 03 2020 Annunciator Audio Module Reference Annunciator Panels 3 Annunciator Audio Module Reference Selection Remote Annunciator Panel requires an internal supply Basic Remote Annunciator Panel requires from another cabinet 1 Panel Type and Mounting Reference a bay assembly with power distribution board a Basic Transponder Interface A100 0620 mounted in Block A and an interconnect harness for connecting to Slot modules and Alarm current 87 mA a bay assembly with power distribution board a remotely powered Transponder Module mounted in Block A and an interconnect harness for connecting to Slot modules and Alarm current 87 mA 2 Remote Command Center Option Mounted LCD Annunciator 2 line by 40 LCD with LED illumination LED illumination off during supervisory turning on with alarm or switches are activated and Mounting Reference requires the top bay 4100ES flat modules are allowed behind it RUI RUI RUI connection is required current 65 mA w o backlight current 140 mA for InfoAlarm Command Center expanded content display products refer to data sheet AC4100 1045 3 Rev 2 03 2020 Annunciator Panels 3 Emergency Voice Alarm Communications Operator Interface Options Remote Microphone mike Module Channel audio or mike Channel audio mike Channel full audio Channel Interface and Mounting Reference panel module requires 2 Slots 4 in 51 mm space behind accepts flat modules only requires dedicated wiring to fire alarm control panel control module Supv 2.4 mA Active 6 mA slot modules requiring connection to an LED switch controller space accepts 4100ES flat modules only adjacent LED switch module s are for specific speaker circuit selection refer to document AC4100 1034 audio reference and document AC4100 0032 for LED switch module Supv 0 Alarm 24 mA 4 Firefighter Telephone System Products Master Telephone refer to document AC4100 1034 for additional detail Module with 3 Class B phone NACs Class A Adapter Module and Mounting Reference in two vertical blocks of bay front locate as required space behind 4100ES flat modules only Block module mounts to bay mounting plate to A100 1272 no additional space required available with Color s per Switch top and bottom on top Yellow on bottom Red on left 8 Yellow on right LED switch controller and label kit is ordered separately Refer to data sheet AC4100 0032 for additional LED Switch module selections 5 LED and LED Switch Modules General Purpose Color s on top Yellow on bottom