Autocall Addressable Fire Detection and Control MINIPLEX Transponders
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-addressable-fire-detection-and-control-miniplex-transponders-0374698512.pdf |
---|---|
Type | |
Size | 3.38 MB |
Downloads |
Text Preview
4100ES Fire Control Units Transponders with ES PS Power Supplies MINIPLEX transponders connect to a host 4100ES Fire Control Panel using Autocall remote unit interface RUI At the transponder RUI communications are received the transponder interface module and translated into the same communications format that is used in the host control panel located modules With RUI communications the can remotely provide the same initiating and notification that occur at the host control panel without requiring multiple distance wiring runs Connections to the host panel are low current and audio wiring with distances up to 2500 ft 762 m refer to document AC4100 1031 and the other documents in Additional 4100ES Product Reference for additional information the extensive initiating and notification features of the fire alarm control panels ULC CSFM Listed FM Approved Approved Series MINIPLEX transponders allow remotely located and notification functions Transponder operation is available as standard or with local mode Communications with the host fire alarm control panel use the Remote Interface RUI and RUI formats functions include Conventional initiating device circuit IDC support Addressable device support including TrueAlarm analog sensor functions include Addressable strobe and horn notification using enhanced power IDNAC SLCs Conventional DC notification appliance circuits including TrueAlert and horn appliances Emergency voice alarm communications mode operation provides Default local initiating and notification operation in the event of a loss with the host control panel Support for conventional Initiating Device Circuits IDC conventional Appliance Circuits NAC addressable IDNet devices IDNAC notification appliances and default output tones local amplifiers modules include Digital or Analog audio riser modules for connection to system audio Digital or analog input audio amplifiers with integral on board NACs Power supplies with or without battery chargers City Connect modules and RS 232 ports for printers or maintenance modules Alarm relays auxiliary relays additional IDC modules and NAC 1 IP30 cabinets are equipped with solid doors platinum or and in one two or three bay sizes to UL 864 Fire Detection and Control UOJZ Smoke Control Service Releasing Device Service SYZV Emergency Communication Relocation Equipment UOQY UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Service SYZV7 CAN ULC S559 Central Station Fire Alarm System Units DAYR7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 1 Typical 4100ES MINIPLEX System One Line Drawing Bay Description model A100 9600 includes a bay assembly a power interface module PDI a Basic Transponder Interface and an interconnect harness Communications with the host alarm control panel are via a Remote Unit Interface RUI connection allows for up to 2500 ft 762 m distance RUI can communicate with to a total of 31 remote devices and can be either Class B or Class X model A100 9601 substitutes a Local Mode Transponder for the Basic Transponder Module Expansion Bays each include a PDI and accept a variety of modules refer to tables from MINIPLEX Transponder Product onwards Battery Compartment bottom accepts two batteries up to 50 that can be mounted within the cabinet Battery mounting does interfere with available module space A power supply with battery is required for each battery set Additional listings may be applicable contact your local Autocall product supplier for the latest status AC4100 1035 Rev 4 09 2021 Transponders with ES PS Power Supplies Availability Modules are power limited except as noted such as battery chargers city circuits and relay modules Enclosure are available for one two or three bay sizes or for cabinet rack mounting NEMA 1 IP30 boxes and solid doors are available in platinum or red ordered separately Up to eight close nippled cabinets can be connected at one transponder location close nippled is mounted within 20 ft 6 m and with wiring enclosed in conduit Refer to document AC4100 0037 for enclosure details Mode Operation Stand Alone Operation In the event of a communications loss with the host fire alarm control panel model A100 9601 MINIPLEX Local Transponders provide fire alarm response default operation for its connected devices and appliances per the following Operation During local mode operation conventional initiating devices and addressable IDNet initiating devices shall be capable of reporting alarm condition to the MINIPLEX transponder TrueAlarm sensors will cause an alarm at their least sensitive alarm threshold Photoelectric sensors will alarm at 3.7 ft smoke obscuration Heat sensors will alarm at a fixed temperature of 135 57 TrueAlarm device LEDs will be activated to indicate a device in alarm Operation Fire alarm conditions reported against a fire alarm point type within a transponder in local mode will cause all notification circuits in that transponder to Sound a general alarm temporal pattern horn tone Activate visible notification appliance circuits Mode Module Support Local mode operation provides support for the following MINIPLEX transponder circuits Conventional NAC and addressable IDNAC notification appliance circuits operated at a temporal pattern IDNet IDNet 2 and IDNet 2 2 addressable device circuits 4100ES amplifiers will provide their on board horn tones 500 Hz at a temporal pattern through their on board amplifier NACs Firefighter Telephone control modules in local mode Mode Operation Module Exclusion Modules and circuits not listed above but that are listed as compatible with MINIPLEX transponders per document do not interfere with local mode operation but are not supported during local mode operation 2 AC4100 1035 Rev 4 09 2021 Multi Floor MINIPLEX Audio System Transponders with ES PS Power Supplies 3 AC4100 1035 Rev 4 09 2021 Bay Module Loading Reference Transponders with ES PS Power Supplies Definitions Block 4 W x 5 H 102 mm x 127 mm card area 2 W x 8 H 51 mm x 203 mm motherboard with daughter card Power limited Interface Modules Riser Modules Block Module 2 and IDNet 2 2 Modules 2 A Relays 10 A Relays 3 A Relays Interface Point Zone Relay Card Amplifiers 2 max bay Amplifiers 2 max bay W Amplifiers 1 max bay W Backup Amplifiers 1 max per bay with primary amplifier Expansion Module Signal Module Card Card Configured as backup A B Block Block Block 2 Slots Block 1 Slot Block E F C D or A B E F or C D E F G H A B C D Block Block Block Blocks on ES Power Supply only G H ONLY E F ONLY Blocks When mounting dual Flex amplifiers on an expansion bay special mounting rules apply 4 AC4100 1035 Rev 4 09 2021 Transponders with ES PS Power Supplies 1 ES Power Supply Specifications ES PS and ES XPS VAC A A Specifications Input Power VAC 240 VAC DC Output Power Capacity Fan A100 5131 Fan and