Autocall Addressable Fire Detection and Control MINIPLEX Transponders Fire Control

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Control Panels Fire Detection and Control MINIPLEX Transponders Series MINIPLEX transponders allow remotely located and notification functions Transponder operation is available as standard or with local mode Communications with the host fire alarm control panel use the Remote Interface RUI format functions include Conventional initiating device circuit IDC support Addressable device support including TrueAlarm analog sensor functions include Conventional DC notification appliance circuits including TrueAlert and horn appliances Emergency voice alarm communications mode operation provides Default local initiating and notification operation in the event of a loss with the host control panel Enabling of an optional Local Mode Controller with a local alarm LED status indicators and keyswitch enabled control switches Support for IDNet addressable devices conventional notification and default output tones from local amplifiers modules include Digital or Analog audio riser modules for connection to system audio Digital or analog input audio amplifiers with integral on board NACs Power supplies with or without battery chargers City Connect modules and RS 232 ports for printers or maintenance modules Alarm relays auxiliary relays additional IDC modules and NAC 1 IP30 cabinets are equipped with solid doors platinum or and in one two or three bay sizes to UL 864 Fire Detection and Control UOJZ UL 2017 Process Management Equipment QVAX UL 1076 Proprietary Alarm Units Burglar APOU UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM 1 4100ES MINIPLEX System One Line Drawing MINIPLEX transponders connect to a host 4100ES Fire Control Panel using Autocall remote unit interface RUI At the transponder RUI communications are received the transponder interface module and translated into the same communications format that is used in the host control panel located modules With RUI communications the can remotely provide the same initiating and notification that occur at the host control panel without requiring multiple distance wiring runs Connections to the host panel are low current and audio wiring with distances up to 2500 ft 762 m refer to document AC4100 0031 and the other documents in Additional 4100ES Product Reference for additional information the extensive initiating and notification features of the fire alarm control panels This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 2269 0542 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 18 01 2020 documentfirealarmresources com Fire Detection and Control MINIPLEX Transponders Bay Description model A100 9600 includes a bay assembly a power distribution interface module PDI a Basic Transponder Interface Module and interconnect harness Communications with the host fire alarm control panel are via a Remote Unit Interface RUI connection that allows for up to ft 762 m distance RUI can communicate with up to a total of 31 remote devices and can be either Style 4 or Style 7 communications model A100 9601 substitutes a Local Mode Transponder Module for the Basic Transponder Module Expansion Bays each include a PDI and accept a variety of optional modules refer to tables from MINIPLEX Transponder Product Selection Battery Compartment bottom accepts two batteries up to 50 Ah that can be mounted within the cabinet Battery mounting does not with available module space A power supply with battery charger is required for each battery set Availability Modules are power limited except as noted such as relay modules Enclosure are available for one two or three bay sizes or for cabinet rack mounting NEMA 1 IP30 boxes and solid doors are available in platinum or red ordered separately Up to eight close nippled cabinets can be connected at one transponder location close nippled is mounted within 20 ft 6 m and with wiring enclosed in conduit Refer to document AC4100 0037 for enclosure details Mode Control Operation Stand Alone Operation In the event of a communications loss with the host fire alarm control panel model A100 9601 MINIPLEX Local Transponders provide fire alarm response default operation for its connected devices and appliances per the following Operation During local mode operation TrueAlarm initiating devices connected to the transponder will cause an alarm at their least sensitive threshold Photoelectric sensors will alarm at 3.7 ft smoke obscuration Ionization sensors will alarm at 1.3 ft obscuration Heat sensors will alarm at a fixed temperature of 135 57 TrueAlarm device LEDs will be activated to indicate a device in alarm Operation Fire alarm conditions reported against a fire alarm point type within a transponder in local mode will cause all notification circuits in that transponder to Sound a general alarm temporal pattern horn tone Activate visible notification appliance circuits Mode Module Support Local mode operation provides support for the following 4100ES modules System Power Supplies SPS Expansion Power Supplies XPS and Remote Power Supplies RPS including on board notification appliance circuits and expansion signal modules operated at a temporal pattern IDNet addressable device circuits including those on board the SPS and communications from IDNet 2 and IDNet 2 2 modules 4100ES amplifiers will provide their on board horn tones 500 Hz at a temporal pattern through their on board amplifier NACs Mode Operation Module Exclusion Modules not listed above but that are listed as compatible with MINIPLEX transponders per this do not interfere with local mode operation but are not supported during local mode operation Mode Controller During local mode operation an optional Local Mode Controller will indicate status see Figure 2 and can be enabled using a to perform local alarm silence or reset If alarms occurring during local mode are reset using a Local Mode Controller upon restoration of those alarms will not be sent to the master controller If alarms are still present upon restoration of communications then the condition will be reported and host fire alarm control panel programmed alarm functions will occur When communications are re established local mode transponder restores automatically Local Mode Controllers are mounted on three gang plates are available in beige or red and for either flush or semi flush mounting See Mode Controller for details 2 Rev 18 01 2020 documentfirealarmresources com Fire Detection and Control MINIPLEX Transponders 2 Mode Controller Module 3 Rev 18 01 2020 documentfirealarmresources com Multi Floor MINIPLEX Audio System Fire Detection and Control MINIPLEX Transponders 4 Rev 18 01 2020 documentfirealarmresources com Fire Detection and Control MINIPLEX Transponders 1 Additional 4100ES Product Reference 4100ES Product Reference and Battery Cabinet Reference for 4100ES Ah Batteries and Cabinets for 4100ES Battery Brackets Reference Basic Panels with SPS Power Supplies LED Switch Modules Printer Enclosures Command Center with SPS Power Supplies with SPS Power Supplies for ES Net Transponder Product Selection 2 Transponder Type Transponder includes bay equipment with power distribution interface and A100 0620 Basic Transponder Module mounted in Block A Mode Transponder includes bay equipment with power distribution interface and Local Mode Transponder Interface Module mounted in Block A local mode mA mA mA mA mA mA 3 Local Mode Controller Selection mount mount mount mount with white with black local mode mA mA mA mA Mode 3 gang mounted flush req

Related Files