Autocall Addressable Notification Appliances Indoor A O Installation Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-addressable-notification-appliances-indoor-a-o-installation-manual-1924076835.pdf |
---|---|
Type | |
Size | 1.17 MB |
Downloads |
Text Preview
TrueAlert ES Addressable Indoor A O Notification Appliances Installation Instructions warnings and regulatory information When the notification appliance emits light or sound it indicates the possibility of an emergency situation that requires attention of all occupants Always install maintain and test notification appliances within their specifications Failure to follow all safety precautions and instructions result in loss of life and property due to non functioning notification appliances Some notification appliances use high voltage To avoid electrical and avoid damage to appliances make sure that the electrical power for the Notification Appliance Circuit is disconnected at the control before installing repairing or internally adjusting any notification appliances Even with electrical power removed some notification appliances as visible strobes store a high voltage charge The high voltage can cause injury resulting in death from electrical shock DO NOT TOUCH CIRCUITRY REFERENCE Location and quantity of appliances required must conform to the applicable local standards and guidelines the National Alarm and Signaling Code NFPA 72 ULC Standard CAN ULC S524 Installation of Fire Alarm Systems the appropriate model building codes and specific requirements of the Local Authority Having Jurisdiction AHJ These notification appliances are not intended for installation within locations as defined by the National Electrical Code NEC or NFPA 1 UL listed TrueAlert indoor product identification reference Mount Horn Audible AO appliances provide an audible warning of an alarm condition when from the control panel of a UL ULC Listed Autocall Fire System For information about TrueAlert appliance testing see TrueAlert ES Addressable Appliances testing and applications guide 579 1049 instructions contents Appliance x 1 x 1 Backplate x1 with 8 32 1 inch mounting screws x 2 and 6 32 1 inch mounting screws x 2 included Electrical box 1 1 2 inch 38.1 mm minimum depth required single gang double gang or 4 inch 101.6 mm square 2 Kit contents the mounting location and install the electrical box using screws suitable for the mounting surface See Figure 1 for mounting and information the building wiring through the rectangular opening in the backplate the building wires to the backplate See Wiring Instructions on page 2 the backplate to the electrical box using the provided hardware Install with the writing Install this side up at the top Use a torque to tighten the screws to 12 15 inch pounds Do not over tighten the screws the cover to the appliance the appliance settings See Setting the address DIP Switch on page 3 the assembled appliance onto the backplate 1 Mounting Instructions Rev G 72 requires thatthe device is notless than 80 in 203.2 cm and not greater than96 in 243.8 cm abovethe finished floor Single gang double gang or 4 in 101.6 mm square electrical box BackplateAppliance coverBuilding wireScrews Use 8 32 screws for a 4 in 101.6 mm square electrical box Use 6 32 screws for a single or a double gang electrical boxAppliancefirealarmresources com ES Addressable Indoor A O Notification Appliances Installation Instructions Instructions Make sure that all power is disconnected before starting the installation the electrical box connect the building wiring to the CKT and CKT terminals on the backplate ensure proper continuity use a torque wrench to tighten the terminal block screws to 12 15 inch pounds that correct polarity is maintained for each unit Line Circuit SLC wiring must be twisted pair TWP CKT terminals accept two wires 12 18 American Wire Gauge AWG TWP Do not bring the conduit through the rear of the electrical box Strip the lead insulation to 7 16 inch maximum 2 Wiring Instructions notes The maximum number of appliances on a circuit or on an IDNAC SLC is 127 The maximum wire resistance between appliances is 26 ohms the field wiring diagrams for the driving compatible fire alarm control panel for further instructions Notification appliances are rated using an individual module label Maintain the correct polarity on the terminal connections Terminals 1 and 2 can each accommodate two wires one wire going in and one wire going out to the next appliance TrueAlert SLC wiring connections are supervised and power limited These appliances are rated to the operating voltage limits of 17 31 VDC The appliance may fail to operate as intended and cause permanent to this equipment if it operates outside of these limits Only operate the TrueAlert AO appliances using a compatible power supply T tapping is not permitted on Class A wiring 2 Rev G backplateFrom a compatibleSLC controller see notesTerminal 2CKT Terminal 1CKT Class A wiring see notes T tapping example A O A O A O A O A O A O A OFrom a compatibleSLC controller see notesClass B wiring see notesTo the next applianceor compatible SLCcontroller see notesfirealarmresources com ES Addressable Indoor A O Notification Appliances Installation Instructions the address DIP Switch addressable TrueAlert notification appliance has a unique address that is set using an eight position DIP switch ADDR1 Assign up to 127 addresses to an SLC however the total appliance loading available may be less due to appliance current requirements set the address complete the following steps a number 1 or number 2 Phillips screwdriver or a similar sized object into the opening at the bottom of the appliance and unclip the from the backplate See Figure 3 the switches using a non metallic stylus or the equivalent the set address the horn configuration switch options for the horn can be configured directly on the appliance using the Configuration switch CFIG1 on the back of the appliance See 4 3 Setting the DIP Switch Address 3 AO Settings 2 7 below ON for Panel control 1 Configuration Control OFF to enable Local Audible control 2 Audible Volume High OFF Low ON 3 CAN Horn mode switch must be set to OFF 4 Legacy NAC mode switch must be set to OFF 6 7 8 switches are unused by the horn Leave them set to 3 Rev G 4 Setting the Configuration access the switches ADDR1The DIP switch shown isset at address 7Not used001101011111646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127DIP SWITCHES 5 THROUGH 7000100010110To access the switches CFIG1 Device configuration switchNot used Leave at OFF firealarmresources com 4 Environmental specifications application 17 31 VRMS F to 120 F 0 C to 49 C to 93 non condensing at 104 F 40 C for 18 AWG to 12 AWG 0.82 mm to 3.31 mm 5 Sound pressure level measurement dBA Vrms mode steady mode coded see note 1 specifications voltage range range range Room at 10 Feet accordance with UL464 See 2 volume setting using controller See Note 3 volume setting using controller See Note 3 volume setting volume setting Min Max Min Max Min Max Min Max Room at 10 feet in accordance with ULC S525 see note 4 The coded category covers both Temporal and March time cadences Reverberant dBA measurements are a minimum UL rating based on sound power level measurements made in UL reverberant test chamber High and low volume settings are configured with DIP switch CFIG1 on the controller you install the A4905 9838 Sound Damper the anechoic measurements decrease by approximately 9 dBA 0 C TO 50 C type RMS current mA 6 Current draw 7 ULC directional characteristics for horn left and right left and right up and down up and down The appliances are available in red and white Do not paint or otherwise alter the factory finishes in any way Anechoic dBA levels below 85 do not meet ULC requirements for public notification dBA dBA dBA dBA 2017 Johnson Controls All rights reserved All spec