Autocall Audible Notification Appliances, Chime-Strobes, Model Series A49CHV

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Approved Addressable Notification Appliances Notification Appliances Chime Strobes Model Series A49CHV addressed and controlled low power TrueAlert ES audible only electronic chime strobes Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes on the same SLC to operate with current even under battery backup Wiring supervision to each appliance allows T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring Self Test Mode facilitates an on board sensor to detect the chime output and then report its status to the control panel You can control chimes separately from visible appliances on the same with control panel selection of operation as Temporal Code 3 Time selectable as 20 bpm 60 bpm or 120 bpm Continuous Temporal Code 4 Output of high or low 6 dBA difference selectable at the or from the controller with FACU mode selected at the Unobtrusive Magnet Test diagnostics are available to assist checkout testing of appliances and wiring Electrical test point access without removing cover Listed to UL Standard 464 UL Standard 1638 and ULC Standard S525 Indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses LED to indicate appliance address and is selectable to also briefly the chime to confirm operation design features include Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters available with a variety of lettering Separate covers are available to change application type on site or replacement covers can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or 4 in box flush or surface mount In out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted boxes and to adapt to Autocall 2975 9145 boxes Optional red wire guards see Product selection for more information ES addressable chime strobes ES addressable chime strobes are individually addressed notification appliances that receive power supervision control signals from an Autocall fire alarm control unit providing signaling line circuits SLCs product has been approved by the California State Fire Marshal pursuant to Section 13144.1 of the California Health and Safety See CSFM Listing 7135 0026 0334 for allowable values and or concerning material presented in this document Additional may be applicable contact your local Autocall product supplier the latest status 1 TrueAlert ES Addressable Chime covers are available in red and white a variety of lettering for applications ES operation advantage ES addressable appliances on IDNAC SLCs provide separate and visible notification using a single two wire circuit that also connection to the individual notification appliance electronic This operation increases circuit supervision integrity by providing that extends beyond the appliance wiring connections current facilitates efficient IDNAC SLC operation IDNAC SLCs a constant 29 VDC source voltage is maintained during battery standby allowing strobes on the same SLC to at higher voltage with lower current and ensuring a consistent draw and voltage drop margin under both primary power and battery standby Efficiencies include wiring distances up two to three times farther than with conventional notification or for more appliances for each IDNAC SLC or use of smaller wiring or combinations of these benefits all providing installation maintenance savings with high assurance that appliances that during normal system testing will operate during worst case conditions installation and testing time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When using Class B wiring T tapped wiring is possible more savings in distance wire conduit size and utilization and installation efficiency Use of Self Test and Magnet Test features installation efficiency TrueAlert device reports conveniently information about each connected appliance Additional listings may be applicable contact your local Autocall product supplier for the latest status Rev 3 6 2021 Notification Appliances Chime Strobes Model Series A49CHV ES diagnostics features IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test feature you can appliance operation without leaving the control unit Additionally you can select each appliance LED to pulse when it receives a supervision during normal operation details Self Test Mode from the control unit allows on board sensors depending on the device type to detect its own strobe and chime output and report their status to the control unit Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously activated individually activated by applying a magnet Refer to control unit data sheet for more Self Test information Appliance Magnet Test this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently indicate the appliance address Appliance Magnet Test this test mode after the address is indicated by pulsing the appliance LED the chime will briefly sound to indicate proper operation Instrument Two TSIT 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control unit Please contact your local Autocall representative for additional information addressable wiring isolator model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring data sheet AC4905 0001 selection appliance only Select cover and mounting plate separately 1 TrueAlert ES addressable electronic chime strobes 2 Separate mounting plate required when ordering SKU A49CHV APPLW plate select color to match cover 2 Rev 3 6 2021 Notification Appliances Chime Strobes Model Series A49CHV ES Chime specifications 3 Appliance general specifications H x W x D instructions 1 8 in x 5 in x 1 1 2 in 130 mm x 127 mm x 38 mm to 120 0 to 49 to 93 non condensing at 104 40 blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires each terminal for in out wiring Use Unshielded Twisted Pair UTP for wiring 4 Sound pressure level measurement dBA VDC room at 10 feet in accordance with UL464 note 1 volume setting using Addressable Controller note 2 volume setting using Addressable Controller note 2 Anechoic room at 10 feet 3 meters volume setting volume setting max max max max rating dBA level Reverberant dBA measurements are a minimum UL rating based on sound power level measurements made in UL reverberant test chamber High and low volume settings are configured with DIP Switch CFIG1 on the Controller 5 Directional characteristics for 49CHV chime left and right left and right above 48 below above 60 below The appliances are available in red and white Do not paint or otherwise alter the factory finishes in any way These appliances with anechoic dBA levels below 85 do not meet ULC requirements for public notification These appliances do not meet the requirements for Canadian Two Stage Operation 3 Rev 3 6 2021 Notification Appliances Chime Strobes Model Series A49CHV 6 Maximum RMS operating current type selection cd cd cd cd cd cd For connection to IDNAC SLCs The use of optional colored lenses can affect the device candela output See TrueAlert ES A V an

Related Files