Autocall Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-audible-notification-appliances-multi-tone-horns-with-520-hz-output-8349012576.pdf |
---|---|
Type | |
Size | 1.44 MB |
Downloads |
Text Preview
Datasheet Addressable Notification Appliances Notification Appliances Multi Tone Horns with 520 Hz Output ULC Approved FM addressed and controlled TrueAlert ES multi tone horns Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each appliance allows T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring Self Test Mode allows an on board sensor to detect the horn output then report its status to the control panel Per appliance tone selection of 520 Hz Horn Broadband Horn Bell High Low Slow Whoop or Siren programmable from the panel or selected using an on board DIP Switch see TrueAlert Multi Tone Horn Specifications 520 Hz tone is compliant with NFPA 72 Low Frequency Signal for Sleeping Areas Listed for wall or ceiling mount applications blank covers are for ceiling mount applications Horn Bell and High Low tones can be controlled as Temporal Code Temporal Code 4 March Time selectable as 20 60 or 120 bpm or Slow Whoop Siren and Chime tone selections are controlled as continuous operation Output of high or low 6 dBA difference selectable at the or from the controller with FACP mode selected at the Unobtrusive Magnet Test diagnostics are available to assist and testing of appliances and wiring Electrical test point access without removing cover Listed to UL Standard 464 and ULC Standard S525 Indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses LED to indicate appliance address and is selectable to also briefly the horn to confirm operation design features include Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters available with FIRE FEU FEU FIRE blank lettering Separate covers are available to change application type on site or replacement covers can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or 4 inch box flush or surface mount In out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted boxes and to adapt to Autocall 2975 9145 boxes 1 ES Multi Tone Addressable are Available in Red with White and White with Red Lettering ES multi tone horns ES multi tone horns are individually addressed audible appliances that receive power supervision and control from a Autocall fire alarm control panel providing IDNAC Signaling Circuits SLCs See IDNAC SLC Controller Compatibility Reference ES Operation Advantage ES addressable appliances on IDNAC SLCs provide audible and visible notification using a single two wire circuit also confirms connection to the individual notification appliance circuit This operation increases circuit supervision integrity providing supervision that extends beyond the appliance wiring current allows efficient IDNAC SLC operation With IDNAC a constant 29 VDC source voltage is maintained even during standby allowing strobes on the same SLC to operate at higher with lower current and ensuring a consistent current draw and drop margin under both primary power and secondary battery Efficiencies include wiring distances up to 2 to 3 times farther with conventional notification or support for more appliances per SLC or use of smaller gauge wiring or combinations of these all providing installation and maintenance savings with high that appliances that operate during normal system testing will during worst case alarm conditions Installation and Testing Time With separate controls on same two wire SLC installation time and expense for both retrofit new construction can be significantly reduced When Class B wiring used wiring can be T tapped allowing more savings in distance conduit size and utilization and overall installation efficiency Use Self Test and Magnet Test features improves installation efficiency device reports conveniently identify information about each appliance Additional listings may be applicable contact your local product supplier for the latest status Rev 6 03 2021 Notification Appliances Multi Tone Horns with 520 Hz Output ES Diagnostics Features When IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test appliance operation can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it a supervision poll during normal operation Details Selecting Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe horn output and then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all simultaneously activated or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see SLC Controller Compatibility Reference Appliance Magnet Test In this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently the appliance address Appliance Magnet Test In this test mode after the address is indicated by pulsing the appliance LED the horn will briefly sound to proper operation Instrument Two TSIT The 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert appliances to its ability to test IDCs NACs and IDNet communications before connection to the control panel Please contact your local Autocall for additional information Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning See data sheet AC4905 0001 Selection Color cover and mounting plate separately 1 TrueAlert ES Addressable Multi Tone Horns with Cover Model numbers ending in BA APPLW models and separate mounting plates are assembled in the USA Separate mounting plate required when ordering model A49MT APPLW 2 Separate Mounting Plate plate select color to match cover 3 Separate Covers 4 Mounting Adapters Separate cover required when ordering model A49MT APPLW uses same cover as A49AO series fixed tone horns White Mount Adapter Skirt H x 5 W x 1 D 136 mm x 133 mm x 41 mm Total depth horn 3 79 mm Adapter Plate for mounting to Autocall 2975 9145 Box for retrofit mount vertical or horizontal Mounting Box requires A4905 9931 Adapter Plate 5 x 5 x 0.060 Thick 211 mm x 146 mm x 1.5 mm x 5 x 2 D 200 mm x 130 mm x 70 mm Only 2 Rev 6 03 2021 Reference Notification Appliances Multi Tone Horns with 520 Hz Output Plate and Surface Mount Installation Reference 2 Plate and Surface Mount Installation Reference Figure 2 shows 2975 9145 Box A4905 9931 Adapter Plate Surface Mount Side View Reference shows optional surface mount adapter skirt 1 1 2 deep A4905 9937 Red A4905 9940 White conduit are provided on all four sides SLC Controller Compatibility Reference 5 IDNAC SLC Controller Compatibility Reference Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply Sheet Output SLC Output Voltage Reference SLC VDC regulated VDC 6 VDC drop 3 Rev 6 03 2021 Notification Appliances Multi Tone Horns with 520 Hz Output ES Multi Tone Horn Specifications