Autocall Audible Visible LED Notification Appliances, Wall Mount Multi-Candela Horn LED Strobe, Model Series 59AV
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-audible-visible-led-notification-appliances-wall-mount-multi-candela-horn-led-strobe-model-series-59av-6031249785.pdf |
---|---|
Type | |
Size | 6.27 MB |
Downloads |
Text Preview
Datasheet LED Addressable Notification Appliances LED Notification Appliances Wall Mount Multi Candela Horn LED Strobe Series 59AV ULC Approved FM addressed multi candela TrueAlert ES LED A V notification appliances Multi candela LED strobe available in low 15 30 and 75 cd and high 135 and 185 cd range candela models Small compact design and low current draw due to energy efficient LEDs Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allow strobes to operate with lower current even battery backup Strobe intensity can be programmed from the control panel or the Wiring supervision to each appliance allows T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring Self Test Mode allows on board sensors to detect the strobe and horn and then report their status to the control panel TrueAlert Device Reports at the control panel detail appliance point ID label type and candela setting Magnet test diagnostics assist checkout and testing of appliances and Compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard Horn operation is listed to UL Standard 464 and ULC Standard Synchronized LED strobe and piezo operation on the same IDNAC Indicator and Magnet Test Indicator LED indicates magnet test acknowledgment 3 digit IDNAC and candela rating supervision Indicator LED can be configured to blink every polling cycle to indicate When the controller is in diagnostic mode the magnet test pulses the LED to indicate appliance address and can be set to also flash the strobe LEDs and sound the horn design features Rugged high impact flame retardant thermoplastic housing in red and colors white with red letters Various covers and lettering options available Red with white letters Available with English FIRE lettering Covers can be easily removed without disturbing the connected and avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG Mounts to single gang US electrical boxes Optional mounting adapter plate to adapt to European electrical boxes 1 ES A59AV LED Addressable are Available in Red with White and White with Red Lettering notification appliance horn Harmonically rich output sound for either coded or steady operation Horns sound as Temporal Code 3 March Time pattern continuous or Code 4 controlled separately from visible appliances on the two wire circuit Selectable March Time rates of 20 60 or 120 beats per minute Output is high or low 5 dBA difference selectable at the appliance from the controller with FACP mode selected at the appliance ES 59 series LED A Vs are individually addressed audible visible notification that receive power supervision and control signals from a fire alarm control panel providing IDNAC Signaling Line Circuits SLC Controller Compatibility Reference Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA Additional listings may be applicable contact your local product supplier for the latest status Rev 4 03 2021 LED Notification Appliances Wall Mount Multi Candela Horn LED Strobe Model Series 59AV ES Operation Advantage circuit integrity ES A V LED addressable appliances on IDNAC SLCs provide visible notification using a single two wire circuit that also confirms connection to individual notification appliance electronic circuit This provides supervision that extends beyond the appliance wiring connections current usage on IDNAC SLCs constant 29 VDC source voltage is maintained even during battery standby This allows strobes to operate at higher voltage with lower current and a consistent current draw and voltage drop margin under both primary power and secondary battery standby Efficiencies include wiring up to 2 to 3 times farther than with conventional notification support for more appliances per IDNAC SLC use of smaller gauge wiring or of these benefits installation and testing time time and expense for retrofit or new construction is significantly reduced with separate controls on the same two wire SLC When Class B is used wiring can be T tapped allowing more savings in distance wire conduit size and utilization and overall installation efficiency Use of and Magnet Test features improves installation efficiency TrueAlert device reports conveniently identify information about each connected ES Diagnostics Test test allows individual appliances to be tested when IDNAC SLCs are in diagnostic mode Test test allows selected devices to detect their own strobe and or horn output and then report their status to the control panel Operation is by VNAC appliance groups and is either automatic all briefly simultaneously activated or individually activated by applying a magnet Refer to panel data sheet for more information on the Self Test feature Appliance Magnet Test Appliance Magnet Test pulses the appliance indicator LED sequentially in response to an applied magnet to conveniently indicate the appliance Appliance Magnet Test Appliance Magnet Test indicates device location by pulsing the indicator LED briefly and then flashes the strobe LEDs and sounds the horn indicate proper operation Instrument Two TSIT Instrument Two TSIT can be used to test IDNAC SLC wiring and TrueAlert ES appliance IDC NAC and IDNet communications before to the control panel Please contact your local Autocall representative for additional information Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring 2 Rev 4 03 2021 LED Notification Appliances Wall Mount Multi Candela Horn LED Strobe Model Series 59AV Selection ES LED Wall Mount Addressable Audible Visible Appliances 1 Appliance only Select cover and mounting plate separately Reference 2 Separate covers Required when ordering appliance only models only rating SLC Controller Compatibility Reference Sheet Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply Output SLC Output Voltage Reference SLC VDC regulated VDC 6 VDC drop 3 Rev 4 03 2021 LED Notification Appliances Wall Mount Multi Candela Horn LED Strobe Model Series 59AV Ratings Operating Voltage Range Requirements SLC Loading Type Setting Chamber UL 464 Test dBA 29.5 VDC Special Application unit load 0.8 mA control panel current of 127 addresses per SLC 139 unit loads 3 Sound Output Ratings 10 ft 3 m 23 VDC with IDNAC SLCs 4 Sound Output Dispersion per ULC S541 Anechoic Testing dBA dBA dBA dBA dBA dBA dBA dBA dBA 50 6 dBA 63 left and right from center dBA 20 above 48 below 6 dBA 65 above 60 below ref center cd mA cd mA cd mA cd mA cd cd Setting VDC RMS Current Ratings with horn on continuous at high setting 5 Percentage of rated light output at room temperature required output output Below Axis Left Right of Axis Characteristics Range Range SLC Wiring Specifications refer to control panel instructions for more information 6 General Specifications