Autocall Audible Visible Notification Appliances, Indoor Ceiling Mount Multi-Candela Horn Strobe, Model Series A49AV
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-audible-visible-notification-appliances-indoor-ceiling-mount-multi-candela-horn-strobe-model-series-a49av-1573804269.pdf |
---|---|
Type | |
Size | 2.21 MB |
Downloads |
Text Preview
Datasheet ES Addressable Notification Appliances Notification Appliances Indoor Ceiling Mount Multi Candela Horn Series A49AV notification appliance horn Harmonically rich output sound for either coded or steady operation Horns sound as Temporal Code 3 March Time pattern continuous or Code 4 controlled separately from visible appliances on the two wire circuit Selectable March Time rates of 20 60 or 120 beats per minute Output is or 5 dBA difference selectable at the appliance from the controller with FACP mode selected at the appliance 1 ES Addressable A V Application Reference selection of visible notification is dependent on occupancy and local codes ES Operation Advantage ES addressable appliances on IDNAC SLCs separate visible and audible notification using a single two circuit that also confirms connection to the individual notification electronic circuit This operation increases circuit supervision by providing supervision that extends beyond the appliance connections current usage on IDNAC SLCs IDNAC SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions Installation and Testing Time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When Class B wiring is used wiring can be tapped allowing savings in distance wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test features improve efficiency TrueAlert device reports conveniently identify about each connected appliance ULC CSFM Listed FM Mount Addressable Visible A V Notification Appliances individually addressed audible visible notification appliances that power supervision and control signals from an Autocall fire control panel providing IDNAC Signaling Line Circuits SLCs LED Xenon tube strobes devices are interoperable on the same IDNAC See TrueAlert ES A V LEGACY Compatibility Reference addressed and controlled multi candela TrueAlert ES audible visible notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected 15 30 75 or 110cd on the AV model or 110 135 or 185 cd on the model Advanced addressable notification controlled by IDNAC SLCs IDNAC SLCs provide regulated 29 VDC allowing horns to operate with current Wiring supervision to each appliance allowing connections Class B circuits to simplify wiring Class A circuits require in out Self Test Mode allows on board sensors to detect the strobe and horn and then report their status to the control panel TrueAlert Device Reports at the control panel detailing appliance point custom label type and candela setting see sample in TrueAlert Reports Reference Magnet Test diagnostics to assist checkout and testing of appliances wiring Electrical test point access by removing the cover Compatibility with ADA requirements refer to important installation in Installation Reference Compatibility with legacy TrueAlert addressable systems for upgrade replacement see TrueAlert ES A V LEGACY Compatibility Strobe operation is listed to UL Standard 1971 and ULC Standard Horn operation is listed to UL Standard 464 and ULC Standard Indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can be set to also briefly flash strobe and sound the horn design features Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters with clear lens available with FEU ALERT FEU FIRE or blank lettering Separate covers are available to change application type onsite or for You can use a back box to mount the appliance assembly to the wall to a 4 inch 10.16 cm square electrical box Covers can be easily removed without disturbing the connected and avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG Optional red wire guards see Product Selection This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0563 7300 2269 0553 7125 2269 0520 and 7125 0026 0380 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable your local Autocall product supplier for the latest status Rev 9 03 2021 Notification Appliances Indoor Ceiling Mount Multi Candela Horn Strobe Model Series A49AV ES Diagnostics Features IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test feature appliance can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it receives a supervision during normal operation Details Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe and or horn output then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see list in Table 10 Appliance Magnet Test this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently indicate the appliance address Appliance Magnet Test this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash and the horn will briefly sound to indicate operation Instrument Two TSIT 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control panel Please contact your local Autocall representative for additional information Addressable Wiring Isolator Model A4905 9929 Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring data sheet AC4905 0001 Reference Device Reports Reference 2 Rev 9 03 2021 Notification Appliances Indoor Ceiling Mount Multi Candela Horn Strobe Model Series A49AV Selection Mount Addressable Audible Visible A V Appliances ES Addressable A V appliance dimensions with cover 8 H x 7 W x 3 D 206 mm x 180 mm x 76 mm 1 Ceiling Mount Addressable Audible Visual Only A V Appliances appliance only Select cover Instructions color Use WP back boxes for surface mounting only Using weatherproof back boxes does not make an appliance weatherproof 2 Back boxes 3 Separate Covers Required when ordering model 49AV APPLC BA logo only logo only