Autocall Audible Visible Notification Appliances; Multi-Tone Horn Strobe with 520 Hz Output
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-audible-visible-notification-appliances-multi-tone-horn-strobe-with-520-hz-output-6592403718.pdf |
---|---|
Type | |
Size | 1.47 MB |
Downloads |
Text Preview
UL ULC CSFM Listed FM Approved Addressable Notification Appliances Notification Appliances Multi Tone Horn Strobe with 520 Hz Output boxes and to adapt to Autocall 2975 9145 boxes addressed and controlled multi tone and multi TrueAlert ES A V audible visible notification appliances Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected as 30 75 110 135 or 185 cd Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each appliance allowing T tapped connections Class B circuits to simplify wiring Class A circuits require in out Self Test Mode allows on board sensors to detect the strobe and horn and then report their status to the control panel Per appliance tone selection of 520 Hz Horn Broadband Horn Bell High Low Slow Whoop or Siren programmable from the panel or selected using an on board DIP Switch refer to Table 520 Hz tone is compliant with NFPA 72 Low Frequency Signal for Sleeping Areas Horn Bell and High Low tones can be controlled as Temporal Code Temporal Code 4 March Time selectable as 20 60 or 120 bpm or Slow Whoop Siren and Chime tone selections are controlled as continuous operation Output of high or low 6 dBA difference selectable at the or from the controller with FACP mode selected at the TrueAlert Device Reports at the control panel detailing appliance point custom label type and candela setting Magnet Test diagnostics to assist checkout and testing of appliances wiring Electrical test point access without removing cover Compatibility with ADA requirements refer to Installation Reference Strobe operation is listed to UL Standard 1971 and ULC Standard Horn operation is listed to UL Standard 464 and ULC Standard Indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can be set to also briefly flash strobe and sound the horn design features include Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters with clear lens available with ALERT or blank lettering Separate covers are available to change application type on site or replacement covers can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or 4 inch box flush or surface mount In out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted 1 TrueAlert ES Multi Tone Addressable are Available in Red with White and White with Red Lettering ES addressable multi tone A Vs ES addressable multi tone A Vs are individually addressed notification appliances that receive power supervision control signals from a Autocall fire alarm control panel providing Signaling Line Circuits SLCs See IDNAC SLC Controller Reference Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA ES Operation Advantage ES addressable appliances on IDNAC SLCs provide visible and audible notification using a single two wire circuit also confirms connection to the individual notification appliance circuit This operation increases circuit supervision integrity providing supervision that extends beyond the appliance wiring current allows efficient IDNAC SLC operation With SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions Installation and Testing Time With separate controls on same two wire SLC installation time and expense for both retrofit new construction can be significantly reduced When Class B wiring used wiring can be T tapped allowing more savings in distance conduit size and utilization and overall installation efficiency Use Self Test and Magnet Test features improve installation efficiency device reports conveniently identify information about each appliance This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0520 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest Rev 7 07 2021 Notification Appliances Multi Tone Horn Strobe with 520 Hz Output ES Diagnostics Features When IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test appliance operation can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it a supervision poll during normal operation Details Selecting Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe and horn output and then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all briefly activated or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see IDNAC Controller Compatibility Reference Appliance Magnet Test In this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently the appliance address Appliance Magnet Test In this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash and horn will briefly sound to indicate proper operation Instrument Two TSIT The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert appliances to its ability to test IDCs NACs and IDNet communications before connection to the control panel Please contact your local Simplex for additional information Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning See data sheet AC4905 0001 Selection 1 TrueAlert ES Wall Mount Multi Tone Addressable Audible Visible Appliances ES multi tone addressable A V appliances include cover and matching mounting plate except as noted Dimensions with Cover 5 H x 5 x 2 D 130 mm x 127 mm x 67 mm cover and mounting plate separately Color Color 2 TrueAlert ES Wall Mount Multi Tone Addressable Audible Visible Appliances BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW models and separate mounting are assembled in the USA Plate select color to match cover 3 Separate Covers Required when ordering model 49MTV APPLW BA uses same covers as A49AV Series fixed tone A Vs Only Only Only 4 Separate Covers Required when ordering model 49MTV APPLW BA uses same covers as A49AV Series fixed tone A Vs 5 Mounting Adapters Red White Red Adapter Plate for mounting to Autocall 2975 9145 Box typically