Autocall Audible Visible Notification Appliances, Wall Mount Multi-Candela Horn Strobe, Model Series A49AV Datasheet

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Addressable Notification Appliances Notification Appliances Wall Mount Multi Candela Horn Strobe Model A49AV ULC CSFM Listed FM Approved addressed and controlled multi candela TrueAlert ES A V notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and intensity programmable from the fire alarm control unit FACU or selected as 15 cd 30 cd 75 cd 110 cd 135 cd or 185 cd Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each appliance allowing T tapped connections for B circuits to simplify wiring class A circuits require in out wiring Self Test Mode allows on board sensors to detect the strobe and horn and then report their status to the FACU TrueAlert Device Reports are available at the FACU detailing appliance ID custom label type and candela setting Magnet Test diagnostics assist checkout and testing of appliances and Electrical test point access access the electrical test point without cover replacement Strobe operation is listed to UL Standard 1971 and ULC Standard Horn operation is listed to UL Standard 464 and ULC Standard indicator and magnet test Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the magnet test pulses the to indicate appliance address and can be set to also briefly flash strobe and sound the horn design features Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters with clear lens available with ALERT or blank lettering Separate covers are available to change application type on site or for A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or a 4 in box flush or surface mount Covers can be easily removed without disturbing the connected and avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted boxes and to adapt to Autocall 2975 9145 boxes Optional red wire guards see Product selection for details Compatibility with ADA requirements see Installation reference Compatibility with legacy TrueAlert addressable systems for upgrade notification appliance horn 1 TrueAlert ES Addressable A Vs are available red with white lettering and white with red lettering Harmonically rich output sound for either synchronized coded or operation Horns sound as Temporal Code 3 March Time pattern continuous or Code 4 controlled separately from visible appliances on the two wire circuit Selectable March Time rates of 20 60 or 120 beats a minute Output is high or low 5 dBA difference selectable at the appliance from the controller with FACU mode selected at the appliance ES addressable A Vs are individually addressed audible notification appliances that receive power supervision and signals from a Autocall FACU providing IDNAC Signaling Line SLCs See TrueAlert ES A V LEGACY compatibility reference for detail application reference Proper selection of visible notification is on occupancy location local codes and proper applications the National Fire Alarm Code NFPA 72 ANSI A117.1 the appropriate building code BOCA ICBO or SBCCI and the application of the Americans with Disabilities Act ADA This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0563 7300 2269 0553 and 7125 0026 0380 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local supplier for the latest status AC49AV 0001 Rev 9 2 2022 Notification Appliances Wall Mount Multi Candela Horn Strobe Model Series A49AV ES operation advantage ES addressable appliances on IDNAC SLCs provide separate visible and audible notification using a single two wire circuit that also connection to the individual notification appliance electronic circuit This operation increases circuit supervision integrity by providing that extends beyond the appliance wiring connections current allows efficient IDNAC SLC operation With IDNAC SLCs a constant 29 VDC source voltage is maintained even during battery This enables strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under primary power and secondary battery standby Efficiencies include wiring distances up to two to three times farther than with conventional or support for more appliances per IDNAC SLC or use of smaller gauge wiring or combinations of these benefits all providing installation maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm installation and testing time With separate controls on the same two wire SLC installation time and expense for both retrofit and new can be significantly reduced When Class B wiring is used wiring can be T tapped allowing more savings in distance wire conduit size utilization and overall installation efficiency Use of Self Test and Magnet Test features improve installation efficiency TrueAlert device reports identify information about each connected appliance ES diagnostics features IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test feature appliance can be confirmed without leaving the FACU Additionally each appliance LED can be selected to pulse when it receives a supervision poll normal operation details Self Test Mode from the FACU allows on board sensors depending on the device type to detect its own strobe or horn output and then their status to the FACU Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously activated or activated by applying a magnet Refer to FACU data sheet for more Self Test information see TrueAlert ES A V LEGACY compatibility Appliance Magnet Test this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently indicate the appliance address Appliance Magnet Test this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash and the horn will briefly sound to indicate operation Instrument Two TSIT 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the FACU Please contact your local Autocall representative for additional information Addressable Wiring Isolator model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring datasheet TrueAlert Addressable Isolator Module Model 4905 9929 AC4905 0001 for information selection 1 TrueAlert ES Wall Mount Addressable Audible Visible appliances see note color color TrueAlert addressable A V appliances include cover and matching mounting plate except as noted dimensions with cover 5 1 8 in H x 5 W x 2 5 8 in D 130 mm x 127 mm x 67 mm cover and mounting plate separately Plate is required when ordering model 2 Separate mounting plate 3 Separate covers required when ordering model 49AV APPLW BA see note Model numbers ending in BA APPLW models and separate mounting plates are assembled in the USA logo only 2 AC49AV 0001 Rev 9 2 2022 Notification Appliances Wall Mount Multi Candela Horn Strobe Model Series A49AV 4 Mounting adapters and wire guard Description

Related Files