Autocall Auto-Aligning Reflective Beam Smoke Detectors with IDNet Communications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-auto-aligning-reflective-beam-smoke-detectors-with-idnet-communications-7924816053.pdf |
---|---|
Type | |
Size | 15.29 MB |
Downloads |
Text Preview
Datasheet Detection Products Reflective Beam Smoke Detectors with IDNet Communications 1 Addressable beam detector head ULC CSFM Listed reflective beam smoke detector system with IDNet addressable communications Compatible with Autocall 4007ES 4010ES and 4100ES fire alarm units FACUs Autocall addressable beam smoke detectors add IDNet to the proven FireRay 5000 Series beam smoke system Communicates status information and receives commands and threshold selection from the host FACU transmitter and receiver are combined in a single housing Connect up to two remote detector heads to one ground level An on board microprocessor analyzes light reflected from an infrared reflecting from a matching prism Operating range covers 26 ft 3 in to 330 ft 8 m to 100 m Modular design with easyfit mounting system and LASER assisted mounting provides convenient mounting and adjustment Auto Align beam alignment operation conveniently rotates beam to to the prism center during installation AutoOptimise operation automatically maintains alignment for reliable UL 268 and ULC S529 listed microprocessor controlled operation includes the Ground level system controller with LCD Operating voltage range 14 VDC to 36 VDC Easy setup and alignment with built in electronic UL ULC obscuration test selectable from host FACU Automatic gain control contamination compensation building shift with control and monitoring of alignment motors and to change Delay to Fire and Delay to Fault timings FACU operations include the following Sensitivity selection from 10 to 60 35 default Point type selection Fire Latched Supervisory or Utility and set FACU information received includes the following Smoke status Controller to Detector Communications status Rapid status beam blocked Self alignment status Almost status Excessively Dirty status and general summary Trouble Analog values for signal strength and compensation level see for more information Dirty threshold beam head LED Initiate obscuration test reset latched conditions Enable Disable and accessories 2 Addressable beam control station Large open areas such as warehouses hotel atriums industrial plants school gymnasiums Public areas where cosmetics are of prime importance and detector need to be small and unobtrusive such as shopping malls theaters and churches Detector adjustment bracket back box and cover plate Controller back box Extended prism mounting options This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7260 2269 0572 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest status AC4098 0049 Rev 6 11 2021 Reflective Beam Smoke Detectors with IDNet Communications installation and alignment addressable beam smoke detection provides the proven FireRay 5000 system features of auto aligning infrared beam smoke detection with IDNet addressable communications When the detector head is installed using the easyfit mounting system an integral laser can activated that alignes along the optical path of the infrared beam Locating the reflective prism is quick and accurate using the Auto Align beam feature Beam Alignment AutoOptimise beam alignment system automatically steers and maintains the beam in the optimum position for reliable performance The element generates the signal the prism reflects it back to the receiver element and then it is analyzed for the presence of smoke The control station determines an alarm condition when it reaches the predetermined level Alarm threshold levels are set using the host FACU to Fire and Time to Fault are set using the beam control station reference maximum distance of the detector and the reflector from the ceiling must be 10 of the distance between the floor and ceiling Lateral detection be up to 30 ft 9.144 m on either side of the beam providing a maximum total coverage area of up to 19,800 square feet 60 ft x 330 ft 18.29 m x m to the installation instructions supplied with the product and to NFPA 72 the National Fire and Signaling Code for additional installation to the host control panel investigate the beam heads remotely the host FACU receives status and numerical information from the beam controller The beam controller commands and the Smoke and Almost Dirty threshold levels are set using the host control panel information received information received includes Signal Strength in to compare to alarm threshold level set by host FACU and Compensation Level an of beam status and dirt accumulation note beam smoke detectors may not be suitable for areas with highly reflective surfaces Separate transmitter or receiver models may be Refer to NFPA 72 and contact your Autocall product representative for additional applications guidance reference images are not to scale Detector on 1220 000 Uni Box Adjustment Bracket Prism Reflector Prism on 1031 000 Mounting Bracket Prisms on 1031 000 Mounting Bracket 2 AC4098 0049 Rev 6 11 2021 Reflective Beam Smoke Detectors with IDNet Communications selection and ordering information 1 Addressable beam detector selection Communications Addressable Reflective Auto Align Beam Smoke Detector one A4098 9020 controller one 5000 031 detector head and one 23901 reflector up to two detector heads IDNet Communications Addressable Reflective Auto Align Beam Smoke Detector Controller only upgrade or replacement Order detector heads and prism reflectors separately 1 4 in H x 7 7 8 in W x 2 13 16 in D mm x 200 mm x 71 mm 9 32 in H x 5 5 16 in W x 5 9 32 in 135 mm x 134 mm x 132 mm 1 8 in x 3 15 16 in x 3 8 in D 105 x 100 mm x 9.5 mm 1 4 in H x 7 7 8 in W x 2 13 16 in D mm x 200 mm x 71 mm 2 Beam detector heads prisms and accessories Back Box Semi Flush Mount Trim Plate for the 5000 009 box Detector Head and Prism select up to one additional head for each A4098 9019 Surface Mount Uni Box with conduit knockouts on all sides White in color Universal back plate mounting Captive screw lock front plate Mounting holes for the optional 1000 018 wire cage Use for 5000 and 3000 Series detector heads Plate pre drilled to mount the reflective detector head to a double gang electric box White in color Bracket for Motorized Reflective Detector Heads with 360 degree rotation and 140 degree adjustment White in color the obsolete 5000 005 Bracket Back Box surface or flush mount Surface mount to single gang double gang or 4 in box 9 32 in H x 5 5 16 in W x 5 9 32 in 135 mm x 134 mm x 132 mm 7 16 in H x 7 7 16 in W x 1 3 4 in D mm x 189 mm x 45 mm 5 16 in H x 8 3 4 in W 263 mm x mm mount wall bracket for prisms Hole pattern for one or four prisms and designed to fit on Unistrut Black in color Order prisms Prism Alignment Adaptor Plate pre drilled to mount one prism Includes 1180 000 Universal Alignment Bracket White in color prism is included with the reflective detector heads mount wall bracket for prisms with hole pattern for one or four prisms and designed to fit on Unistrut White in color Order separately Prism Reflector Range Prism Kit includes three additional prisms for installations between 164 ft and 328 ft 50m and 100m Pendant Mounting Bracket Wire Cage for 5000 Series detector heads Wire Cage for 5000 Series controllers Pendant Mount for the reflective detector head supplied with a 12 in long nipple Use for single or bi directional applications in colo