Autocall Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control Datasheet

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Control Panels Extinguishing Deluge and Preaction Sprinkler System Releasing Control control using the Autocall 4100ES Fire Alarm Control to provide Coverage for multiple areas of Automatic Extinguishing Release and Deluge and Preaction Sprinkler System Release including audible of events Control of compatible Listed Approved valves and actuators Releasing appliance circuits RACs by connecting Notification appliance NACs to Suppression Release Peripherals for actuator and control Escalation of Events Temporal or 20 bpm March Time pattern for first cross zone alarm 120 bpm March Time pattern to indicate releasing timer active On steady to indicate releasing timer expired and actuator is activated Requires NACs dedicated to conventional horn control not operation with strobes controlled on separate NACs Suppression Release Peripheral SRP Dual Command Control Dual command control requires that both IDNet communications and an activated NAC are present to initiate the desired NAC provides wiring supervision to the actuator including monitoring coil continuity and short circuit supervision to the coil supervision Release Peripheral control features An on board DC DC regulator compensates for voltage drops to the and ensures proper control circuit voltage over a wide range Provides a single RAC for control of actuators for up to 2 A using a 3 A input 1 A using a 2 A NAC input system components 4100ES Series control panel with Releasing Appliqu Dedicated NAC output from 4100ES or compatible NAC Extender Coil supervision module one per RAC Maintenance Switch one per RAC Abort Switch connected via an addressable interface module combined with Suppression Release Peripherals the 4100ES fire alarm control panel provides actuator supervision and control use in automatic extinguishing and deluge or preaction releasing Hazard area initiating and notification devices are controlled either conventional or addressable circuits per standard 4100ES The necessary releasing system logic is implemented within 4100ES control panel as required for the local application 1 Series Releasing Typical Block Diagram Release Control operation described in this document is also with 4100U Control Panels with software revision 11.05 or Refer to data sheet AC4100 0031 for model 4100ES control panel including IDNet communications information This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0555 7165 2269 0542 and 7300 2269 0567 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 16 1 2020 Extinguishing Deluge and Preaction Sprinkler System Releasing Control FM Approved Automatic Extinguishing Release requires standby to be a minimum of 24 hours with 5 minutes of Actuators must be electrically compatible FM Approved Deluge and Preaction Sprinkler operation that initiating device circuits be Class A and wired listed approved devices standby power capacity must be minimum of 90 hours with 10 minutes of alarm and that Automatic Water Control Valves must be used Refer to UL Listed Valves and Actuators Maintenance Switches one per RAC are required per NFPA 72 use may not be allowed in some jurisdictions always confirm requirements When used Autocall Maintenance Switches are to ensure that operation initiates a supervisory condition Abort Switches are available when abort operation is required to an addressable Supervised IAM model A4090 9001 or addressable adapter module Addressable Manual Releasing Stations are used to initiate of the releasing actuators with the appropriate time delay by the fire alarm control panel Notification Requirements Each hazard area typically requires audible and visible fire alarm notification and additional NACs for area releasing status notification Suppression is compatible with conventional panel mounted NAC as well as for use with the 4009 IDNet NAC Extender Additional Suppression Release Peripheral Reference Refer Installation Instructions 579 385AC Releasing Systems Reference additional information refer to Factory Mutual Research Corporation FMRC Approval Guide FM Approval standard Automatic for Preaction and Deluge Sprinkler Systems Proper operation of a releasing control system requires that the design installation and maintenance be performed correctly in accordance with all applicable local and national codes and manufacturer instructions No liability for total system oper is assumed or implied listings UL 864 Control Units System UOJZ Control Unit Accessories Fire Alarm UOXX Control Units Releasing Device Service Smoke Control System Equipment UUKL UL 1076 Proprietary Alarm Units APOU UL 1730 Smoke Detector Monitors and Accessories UULH UL 2017 Emergency Alarm System Control Units CO detection FSZI Equipment Management QVAX ULC S527 Control Units System Fire Alarm UOJZC Control Unit System Fire Alarm UOXXC Control Units Releasing Service SYZVC Smoke Control System Equipment UUKLC ULC S559 Central Station Fire Alarm System Units DAYRC CSA 6.19 Gas Alarms and Accessories CZHFC ULC ORD C1076 Proprietary Burglar Alarm System Units APOUC ULC ORD C100 Smoke Control System Equipment UUKLC UL2572 Mass Notification Systems Extinguishing Release Systems systems automatically activate electrically controlled actuators the release of a fire extinguishing agent such as dry chemical water foam CO2 or clean agent in response to fire detection device as determined by programming of the host fire alarm control Extinguishing Release System Panels are required to a minimum of 24 hours of standby power Initiating devices must Listed Approved for the application and may be wired either Class A B Control actuators must be electrically compatible with the control circuits and power supplies and are wired Class B to provide coil or Preaction Sprinkler Systems systems automatically activate water control actuators in to fire detection device inputs Sprinkler Systems employ open sprinkler heads and water flow when the fire detection system activates a common water control actuator They are used to deliver water through all of the system sprinkler heads This type of is applicable where the immediate application of large quantities water over large areas is the proper fire response Sprinkler Systems are similar to deluge systems except normally closed sprinkler heads are used and supervisory air is maintained in the pipe Operation requires both an activated head and an activated fire alarm initiating device with specific determined at the host fire alarm control panel System Requirements Releasing actuators are controlled from a Suppression Release A4090 9005 or A4090 9006 Connections are 2 wire B releasing circuits with only one 24 VDC actuator per Where applicable two 12 VDC actuators in series or one VDC actuator per circuit may be used refer to the actuator installation documentation for additional details requirements Coil Supervision Module A2081 9046 must be wired electrically the actuator and located in the actuator wiring junction box connected RAC provides continuity supervision of the actuator and wiring and provides short circuit supervision to the coil module Cross zoning or other alarm initiation logic per system is to be implemented by programming at the fire control panel UL Listed Automatic Extinguishing Releasing operation that battery standby must be a minimum of 24 hours with minutes of alarm and that listed actuators are used 2 Rev 16 1 2020 Extinguishing Deluge and Preaction Sprinkler System Releasing Control Selection Supervision Module Switches Refer to data sheet AC2080 0010 for Abort and Maintenance switch details mount mount Switch 1 4100ES Releasing Control System Modules one per RAC mounts in the releasing actuator wiring junction box Specificat

Related Files