Autocall BACpac Ethernet Portal Modules Model A100-6069

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Control Units Ethernet Portal Module Model A100 6069 A100 6110 A100 6111 and A010 9915 mounted modules provide fire alarm system status the ASHRAE BACnet building automation communication or Modbus communication protocol protocol reference BACnet Internet Protocol IP or BACnet MS TP serial ANSI ASHRAE Standard 135 Modbus TCP or Modbus RTU serial To fire alarm system through RS 232 port B configured for Computer Output port provides Ethernet local area network LAN or RS 485 Ethernet Module is pre programmed Module is pre programmed with digital pseudo points linked to BACnet You can recognize up to 15000 status changes monitor point status the fire alarm control unit FACU Protocol Autocall fire alarm control units FACU 4100ES Series FACUs and Network Display Units NDU 4010ES Series FACUs reference UL listed to Standard 864 ULC listed to Standard S527 BACpac Ethernet module provides a supplementary interface that converts computer terminal information a compatible Autocall FACU into the building automation protocol BACnet or any industrial equipment using Modbus protocol With this status information from the FACU can be provided to other of the building automation network with the detail and format required this information allows other systems to properly respond to alarm system activity in addition to the primary fire alarm response is under the control of the FACU 1 Building Automation LAN with Autocall FACU BACpac Portal shown with 4100ES panel for reference A100 6069 BACpac Ethernet Module shown document is a summary of the flexibility available with BACnet Please contact your local Autocall product supplier for information concerning your specific application This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7165 2269 0542 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest Rev 7 10 2020 Ethernet Portal Module Model A100 6069 A100 6110 A100 6111 and A010 9915 responsibilities detection and alarm systems are distributed throughout to monitor for indications of the presence of smoke or fire a fire alarm condition is determined the fire alarm system that information with sufficient detail to allow the proper response to begin The fire alarm system may perform other control such as fan shutdown and elevator recall or those actions be performed by other systems that also handle those functions for conditions as well as for abnormal conditions automation systems As buildings increase in size and control of the electrical and mechanical systems requires This process has evolved into the general category of Systems Automation and includes systems such as heating and air conditioning HVAC elevator controls security lighting controls and other similar building functions responses to fire alarm system status changes might include fan control operation elevator capture lighting control and system awareness Specific examples could include turning lighting where needed aiming security cameras on specific areas door release and implementing detailed fan exhaust and or instructions communications between systems Traditional communication systems includes simple relay interfaces proprietary and interface devices gateways and uses a single supplier for of the building automation functions Each of these compromises has limitations With the Autocall BACpac Ethernet module BACnet or protocol communications allow the Autocall fire alarm system provide pertinent status to compatible systems using standardized example 2 shows how a smoldering fire located on the first floor can be by the FACU processed by the BACpac Ethernet module then sent to the building automation system using the BACnet or protocol over a LAN connection It is the responsibility of the to initiate the required notification and related fire responses when connected to a BACpac Ethernet module the fire alarm can make status information available to the other building informing them about facility fire detection activity Serial communication is also possible using the RS 485 output BACnet MS TP or Modbus RTU reference module uses a BACnet and a Modbus protocol converter from Technologies PC compatible diagnostic programs are at www sierramonitor com 2 BACpac Ethernet module alarm process shown with 4010ES panel for reference A010 9918 RS 232 module shown 2 Rev 7 10 2020 Ethernet Portal Module Model A100 6069 A100 6110 A100 6111 and A010 9915 selection Ethernet module for 4100ES series single slot 2 in module Ethernet module for 4100ES series single slot 2 in module Ethernet module for 4100ES series single slot 2 in module Ethernet module for 4010ES series single block module 4 x 5 BACpac modules connect to Port B of these RS 232 modules 1 Product selection RS 232 module separately of sheet 3 Rev 7 10 2020 Ethernet Portal Module Model A100 6069 A100 6110 A100 6111 and A010 9915 protocol implementation conformance PIC reference standardized device profile Annex L interoperability building blocks supported K capability object types supported NOT property property details link layer options address binding sets supported 2 PIC reference Smart Sensor B SS Smart Actuator B SA Application Specific Controller B ASC BIBB Data Sharing ReadProperty B DS RP B BIBB Data Sharing WriteProperty B DS WP B BIBB Device Management Dynamic Device Binding B DM DDB B Object Input Output Value Input Output Value State Input Output State Output State Value CreateObject DeleteObject optional properties additional writeable properties exist proprietary properties exist range restrictions exist main Clause 9 baud rate up to 76,800 bps subordinate Clause 9 baud rate up to 76,800 bps supported X3.4 10656 ICS 4 10656 UCS 2 8859 1 DBCS 4 Rev 7 10 2020 Ethernet Portal Module Model A100 6069 A100 6110 A100 6111 and A010 9915 power input Connect to Port B of Module 3 Specifications VDC from FACU operation range 9 VDC to 30 VDC mA maximum from 24 VDC FACU supply Wires to pluggable terminal block harness included type Module A100 6038 type Computer Port Protocol from FACU terminal block same terminal block as used for input power connects to RS 232 module in alarm control panel harness included compatible communications formatted as BACnet IP internet protocol or Modbus TCP Serial formatted as BACnet MS TP or Modbus RTU RJ 45 jack located on LAN suppressor module part of module assembly LAN Ethernet connector to be supplied separately RS 485 connector harness not included used for serial Instance 32400 IP Address 192.168.1.24 Subnet Mask 255.255.255.0 TX RX RTX CTS DTR DSR DCE and RI located on the processor assembly in Slot type module components are mounted on a metal bracket dimensions 10 7 16 in H x 2 in W x 4 in D 102 mm x 51 mm x 265 mm block module 4 x 5 uses the modules shown in Figure 3 but packaged differently communications and power are connected to the on board pc board assembly for processing pluggable harness supplied connects to a grounded LAN suppressor mounted on the chassis Ethernet LAN cable is supplied separately to 120 0 to 49 to 93 RH non condens

Related Files