Autocall Batteries and Battery Cabinets; 110 Ah Sealed Lead-Acid Batteries and Compatible Battery Cabinet (without charger)

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Accessories and Battery Cabinets 110 Ah Sealed Lead Acid Batteries and Compatible Battery without charger 12 V 110 Ah rechargeable sealed lead acid battery Output terminals are high current posts connecting hardware is with battery cabinet UL ULC fire alarm system requirements are satisfied when these are used with a compatible charger and compatible battery Batteries have UL 924 recognized pressure relief valves Battery Cabinet ordered separately Use when fire alarm control panel internal charger is capable of 110 Ah batteries not applicable for ULC listed 4100ES For compatible Autocall 4100ES systems connection requires two to a A100 5128 Battery Distribution Terminal Block located in the Refer to data sheet AC4081 0002 for 4100ES compatible battery with charger 110 Ah rechargeable sealed lead acid batteries provide and repeatable discharge and recharge characteristics for use fire alarm and other systems applications For use with Autocall fire control panels with battery chargers capable of up to 110 Ah these batteries in external battery cabinet A2081 9280 located to the control panel Details Connections two of these 12 V batteries in series to produce 24 V system Battery sets must be of identical voltage model number and approximately the same date of manufacture for operation chemicals and materials can be recycled Refer to information with the battery or on its case Return to the battery or to a similarly qualified battery processing facility for disposal 1 Batteries 2 required for VDC system actual appearance may vary 2 Battery Cabinet capacity testing is recommended to be performed by using a lead acid battery tester designed to withdraw a minimum of charge Testing is available through your local Autocall product Information to Installation Instructions 574 670AC for Battery Cabinet details See 4100ES basic panel data sheets AC4100 0031 AC4100 0100 for additional power supply battery charger Autocall Battery Chargers Reference Standard System Power Supplies or Enhanced Power Supply EPS A100 9xxx Series Additional EPS Additional EPS A100 5313 A100 5327 This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7315 2269 0561 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest Rev 6 1 2020 and Battery Cabinets 110 Ah Sealed Lead Acid Batteries and Compatible Battery Cabinet without charger Included Protection Terminals weight per battery Voltage weight 1 A2081 9280 Battery Cabinet 1 2 in W x 12 in H x 12 in D 673 mm x 305 mm x 305 mm and cables for compatibility with 2081 9279 batteries mounted fuseholder with 80 A fuse included AWG to 2 AWG 2 mm to 32 mm 49 lbs 22.2 kg with two batteries 213 lbs 97 kg 2 2081 9279 Battery Reference Information 3 16 in W x 9 in H x 10 1 2 in D 284 mm x 230 mm x 267 mm Ah 20 hour discharge rate V per battery 2 required for 24 V system currect terminal posts lbs 37 kg per battery with two batteries 213 lbs 97 kg Wiring and A2081 9280 Battery Cabinet Detail Reference 2 Rev 6 1 2020 and Battery Cabinets 110 Ah Sealed Lead Acid Batteries and Compatible Battery Cabinet without charger Distance Chart Distance per Battery Discharge Current Range 3 Wiring distances Wire mm2 A ft 8 m ft 12.5 m ft 20 m ft 32 m ft 51 m ft 81.7 m ft 130 m A ft 9.5 m ft 15 m ft 24 m ft 38 m ft 61 m ft 97.5 m A ft 10 ft 15.8 m ft 25 m ft 40 m ft 64 m A ft 11.9 m ft 19 m ft 30.5 m ft 48.7 m A ft 13.7 m ft 22 m ft 35 m A ft 17 m ft 27 m A ft 24 m Battery Cabinet Additional Wiring Information battery cabinet output fuse is 80 A for battery protection battery fuse requirement To protect the output conductors install a line fuse rated properly to the load current in the battery plus of each output pair Wire per applicable local code Battery output connects to multiple conductor terminal block for connections to other panels requiring external battery power 3 Rev 6 1 2020 and Battery Cabinets 110 Ah Sealed Lead Acid Batteries and Compatible Battery Cabinet without charger 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 6 1 2020

Related Files