Autocall Cabinet Reference; Boxes, Doors, Dress Panels, Rack Mounting, and Accessories
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-cabinet-reference-boxes-doors-dress-panels-rack-mounting-and-accessories-3916074528.pdf |
---|---|
Type | |
Size | 2.07 MB |
Downloads |
Text Preview
4100ES Fire Control Panels Reference Boxes Doors Dress Panels Rack Mounting and Accessories ULC CSFM Listed 4100ES Box and door options Boxes are available sized for one two or three equipment bays each a battery bay located at the bottom Colors include platinum or red Doors are glass front with modular dress panels or solid Models are available with box and door combined for single package or packaged separately Enclosures are NEMA 1 rated wall mount enclosures are also IP30 Refer to individual 4100ES data sheets for product application listings Enclosure Selection Chart and dress panel selection is coordinated with cabinet Glass doors with modular dress panels provide visibility of and interface modules for Control Panels Network Units NDU and Remote Annunciators Solid doors are for MINIPLEX Transponders and utility function where module visibility is not required Enclosure details Latching dress panels easily lift off for internal access Smooth box surfaces are provided for locally cutting conduit entrance exactly where required Alignment markers are provided at the top and bottom of each box for 6 in 152 mm or 4 in 102 mm wall studs Knockout screw nail holes are supplied for semi flush mounting cabinet rack packaging reference For use with Bud Industries Inc special cabinet rack model number See Table 3 for cabinet rack listing 2 Two Bay Cabinets 3 Three Bay Cabinets 1 One Bay Cabinet 4 Rack Enclosure shown with door open This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 2269 0542 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest status Rev 19 1 2020 Reference Boxes Doors Dress Panels Rack Mounting and Accessories Selection Chart See Wall Mounted Enclosure Installation Reference and Cabinet Rack Specifications for dimensions keys are shipped with system master controller with Glass and Dress with Solid Door and Panel Door 1 Combined Box and Door Selection select if box and door are to be shipped together 1 Bay 2 Bay 3 Bay 1 Bay 2 Bay 3 Bay 2 Separate Box and Door Selection select if boxes and doors are required to be shipped separately 1 Bay Platinum 2 Bay 3 Bay 1 Bay 2 Bay 3 Bay from Bud Industries Inc 3 Cabinet Rack Mounting Listings listed only as of document revision date cabinets are listed with the 4100ES product line upright cabinet rack for 19 in 483 mm E I A gray includes front polycarbonate and rear louvered door both with Autocall B keys Controller Rack Mount Kit one per master controller Bay Rack Mounting Kit one per expansion bay Distribution Module PDM Rack Mount Kit order PDM separately per system voltage one required cabinet rack Controller and Option Bays each require 9 Rack Units 15.75 in 400 mm 4 Power Distribution Modules VAC VAC Distribution Module PDM select system voltage one required per box or cabinet rack 5 Miscellaneous Accessories key one is shipped with system Master Controller order for replacement or when extra keys needed B key and Address Label Kit for module One kit is supplied for each cabinet order if required for additional field module instal 7 in 37 mm wide four corners and trim for top bottom and sides semi flush box trim semi flush box trim 6 Battery Accessories Shelf required for 50 Ah batteries Distribution Terminal Block mounts to side of box required for all close nippled unless cabinet receives all power from power supplies and batteries located in the cabinet 7 Battery Reference Notes lead acid batteries 12 VDC each two required battery location Battery selection is required if are internal Select one size per battery set to data sheet AC2081 0006 for battery details Ah Ah Ah Ah Ah Ah Ah Rev 19 1 2020 2 Mounted Enclosure Installation Reference Reference Boxes Doors Dress Panels Rack Mounting and Accessories 5 Reference Figure 5 shows side view dimensions with minimal cabinet and door protrusion from the exterior wall For 6 in stud construction with minimum pro shown the door opens 90 degrees To allow the door to open 180 degrees the exposed cabinet dimension from the exterior wall must be a of 3 in 76 mm for both 4 in and 6 in stud construction A system ground must be provided for Earth Detection and transient protection devices This connection shall be made to an approved dedicated connection per NFPA 70 Article 250 and NFPA 780 For additional installation information refer to Installation Instructions 579 117 3 Rev 19 1 2020 Data Sheet Reference I O Modules for 4100ES 4010ES 4007ES Basic Panels with SPS Power Supplies Emergency Voice Alarm Equipment Transponders with SPS Power Supplies Remote Annunciator Panels Command Center with SPS Power Supplies with SPS Power Supplies for ES Net Basic Panels with EPS Power Supplies Command Center with EPS Power Supplies Transponders with EPS Power Supplies with EPS Power Supplies for ES Net Package Reference Reference Boxes Doors Dress Panels Rack Mounting and Accessories 8 Reference Sheet 6 side and rear views Rack Specifications Number Dimensions Space Width Door Door Instructions 9 Cabinet Rack Specifications cabinet rack for exclusive use with Autocall 4100ES Fire Alarm Products from Bud Industries Inc www budind com in 1775 mm in 611 mm in 559 mm texture in E I A 483 mm mount with 1 8 in thick 3.18 mm smoke gray polycarbonate locked with Autocall B key hinged left of cabinet top and bottom locked with Autocall B key panels are removable from the inside for rack to rack mounting attached for battery mounting 4 stem levelers on bottom 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 19 1 2020