Autocall Duct Detector Housings with TrueAlarm Photoelectric Detector for 2-Wire or 4-Wire Operation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-duct-detector-housings-with-truealarm-photoelectric-detector-for-2-wire-or-4-wire-operation-6190834572.pdf |
---|---|
Type | |
Size | 2.92 MB |
Downloads |
Text Preview
Datasheet Smoke Detectors Detector Housings with TrueAlarm Photoelectric Detector for 2 Wire or 4 Wire ULC CSFM Listed FM air duct detector housing with clear cover to monitor the presence of smoke factory installed TrueAlarm photoelectric smoke and features On board TrueAlarm sensitivity drift compensation and dirt tracking Multi function status LED indicator Magnetic test that initiates an alarm and provides detailed diagnostic Clear cover allowing visual inspection Test ports provide functional smoke testing access with cover in place UL listed to Standard 268A availability A4098 9685 2 Wire standard operation A4098 9688 2 Wire with supervised control for a single remote relay included A4098 9686 4 Wire operation with supervised control for multiple relays includes one remote relay to rectangular ducts or round ducts Minimum size is 8 203 mm square or 18 457 mm diameter operated functional test Initiates alarm and displays dirt accumulation status using the detector LED dirty detectors Assists with maintenance priorities by categorizing detector status and tubes ordered separately Available in multiple lengths to match duct size Installed and serviced with housing in place module options ordered separately Red alarm LED A4098 9830 Test stations with LED s and keyswitch refer to page 2 for Relays for remote control applications Please note that smoke detection in air ducts is intended to provide of the presence of smoke in the duct It is not intended to will not replace smoke detection requirements for open areas or non duct applications 1 Detector Housing Front and Bottom View Alarm Indicators and Test Stations Autocall air duct smoke detector housings provide a smoke detector for monitoring air conditioning or ventilating Sampling tubes are installed into the duct allowing air to be to the smoke detector mounted in the housing These duct housings with smoke detectors are compatible with Autocall alarm control panels that provide conventional two wire or four wire device circuits IDCs This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 3240 2269 0526 7300 2269 0551 7272 2269 0510 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the status Rev 11 03 2021 Detector Housings with TrueAlarm Photoelectric Detector for 2 Wire or 4 Wire Operation Details supports a remote red alarm LED or a remote test station with LED s Models with relay output provide relay coil wiring supervision that will a trouble to the IDC if supervision is lost Model A4098 9685 provides basic smoke detection for applications that do not require a remote relay Power is from the IDC Model A4098 9688 provides a supervised relay output for connection to a single A4098 9841 relay This model is powered from the IDC and connection as the only device to ensure relay operation Model A4098 9686 provides a supervised relay control output that can control up to 15 4098 9843 control relays Relay supervision troubles indicated by a yellow LED on the interface board Resettable 24 VDC is required see Specifications Remote test station A4098 9835 is available use with this model to provide a test keyswitch a red LED alarm indicator and a green power on LED Detector Selection Chart 1 Duct Smoke Detector Housing with Photoelectric Detector relay s Duct Detector standard operation Duct Detector with supervised single remote relay output includes one relay Must be only device on IDC for proper relay operation When used with Autocall 4004 or 4005 fire alarm control panel connect to high current only Duct Detector with supervised multiple remote relay output requires 24 VDC fire alarm power and relay end of line resistor A4081 9008 one 4098 9843 relay relay is required for operation to 15 total 4098 9843 relays relays are ordered LED and stations per 2 LED Indicator and Remote Test Stations Select one if required Each assembly is a single gang stainless steel plate wiring is 18 AWG 0.82 mm2 color coded wire leads LED alarm indicator Station with keyswitch and red LED alarm indicator turning switch to initiates alarm for system testing Station with keyswitch red LED alarm indicator and green power on LED A4098 9686 only single gang box 3 H x W x 2 D 76 mm x 51 mm 51 mm 3 Epoxy Encapsulated Remote Relays and End of Line Resistor wiring is 18 AWG 0.82 mm2 color coded wire leads dual Form C 1 2 A 120 VAC included with single Form C 7 A 120 VAC one included with Resistor Harness 10 k 1 2 W ref 733 894 required to remote relay coil connection to pages 3 and for additional relay only one only up to 15 relays within 3 1 m of device being per NFPA 72 last relay location Each duct housing includes an internally mounted model A4098 9601 TrueAlarm photoelectric detector and an exhaust tube A correctly sized tube ordered per application is required refer to chart below Tube Selection Chart Ordered Separately Per Duct Width Select One 4 Sampling Tube Selection Chart Duct Width 305 mm to 23 330 mm to 584 mm to 46 610 mm to 1168 mm to 71 1168 mm to 1803 mm to 95 1803 mm to 2413 mm Required Cut Length 12.7 mm longer than duct width 12.7 mm longer than duct width in 76 mm longer than duct width in 76 mm longer than duct width in 76 mm longer than duct width 2 Rev 11 03 2021 Detector Housings with TrueAlarm Photoelectric Detector for 2 Wire or 4 Wire Operation Detector Status LED Indications Indication approximately every 4 seconds On 5 Status LED Indications 6 Detector LED Response to Magnetic Test Indication turns ON pulses quickly 6 times in 3 then turns ON pulses slowly 4 times in 8 then turns ON By is initiated is initiated is initiated not initiate Alarm sensitivity is within compensation sensitive out of normal range sensitive out of normal compensation is malfunctioning or other service is is required Testing requires placing a magnet at the designated location on the duct housing cover for 4 seconds and referring to the response from the red status indicator on the detector Refer to Installation Instructions 574 776AC for further test and maintenance information 3 Rev 11 03 2021 Detector Housings with TrueAlarm Photoelectric Detector for 2 Wire or 4 Wire Operation Detector Housing Detail Reference Refer to Installation Instructions 574 776AC for additional detail and maintenance information A4098 9686 only Remote Relay 4098 9843 Remote Relay A4098 9841 4 Rev 11 03 2021 Detector Housings with TrueAlarm Photoelectric Detector for 2 Wire or 4 Wire Operation Detector Location Reference Detector Location Considerations Proper duct smoke detection location must ensure adequate airflow within the duct housing Duct air velocity rating is 300 to 4000 ft min 91 to 1220 m min Pressure differential between intake and exhaust tubes is required to be 0.015 to 1.55 inches of water 0.381 to 39.37 mm Ensure accessibility for test and service Proper Locations downstream side of filters to detect fires in the filters in return ducts ahead of mixing areas upstream of air humidifier and coil Other locations and orientations may be required for proper duct smoke detection depending on duct access system design and duct airflow Contact your local Autocall product supplier for assistance to Avoid Whe