Autocall Emergency Communication Systems and Mass Notification Systems
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-emergency-communication-systems-and-mass-notification-systems-4256783901.pdf |
---|---|
Type | |
Size | 2.06 MB |
Downloads |
Text Preview
Datasheet Voice Control Unit Communication Systems and Mass Notification Systems Approved ANSI UL 864 Control Accessory CSFM Listed 4003EC Voice Control Unit adds digital voice message capability to fire alarm control units Remote booster amplifiers are available to expand coverage area or to multiple notification areas Activate up to 8 separate messages by direct connection to fire control unit FACU NACs using the NAC Interface Module or by a supervised connection to relay contact closures 4003EC voice control unit status alarm system trouble or separate trouble is through isolated contact closure allowing compatibility a wide range of Autocall brand and other fire alarm systems Multiple 4003EC control units can interconnect for system wide Communication Systems ECS Mass Notification Systems message control using Autocall fire alarm network node Broadcast live messages using the internal microphone or up to 18 microphones Select from 8 digitally pre recorded messages using the control switches or controlled from the FACU select a pre tone and a post tone if desired You can order custom messages separately as custom chip sets record directly at the unit requires external equipment new override standard messages control unit details Efficient Class D amplifier design provides 40 W at 25 VRMS or 70.7 with power limited output One general alarm Class B audio NAC rated at 40 W can be expanded to four Class B NACs or two Class A NACs using a A B Splitter One general alarm Class B 2 A strobe NAC with strobe formatted to synchronize either Autocall or Cooper Wheelock strobes not mixed Internal push to talk microphone and individual manual tone or controls for convenient operator control Strobe circuit activation is DIP switch selectable for each recorded for microphone use and for auxiliary input Multiple connections are available for auxiliary output power 24 1 2 A maximum Internal battery charger for up to 12 Ah batteries in cabinet or up to Ah batteries in a separate cabinet Removable terminal blocks for easy wiring Beige or red cabinet for surface mounting booster amplifier details Remote booster amplifiers are available with 80 W with 2 2 A circuits 160 W and 320 W each has an efficient Class D design Wiring options allow limited or detailed control with respect to power failure and non fire alarm operation modes Wiring options allow control of non alarm audio output when on standby and selection of monitoring main trouble contacts or trouble contacts 1 4003EC Voice Control Unit Removable terminal blocks for easy wiring Beige or red cabinet for surface mounting optional features Supervised remote microphones with key switch control beige or for alarm paging Local Operating Console LOC providing enclosed microphone and control for the 8 unit messages Application Note For control from a Wide Area Notification System audio 1 VRMS 600 ohm and contact closure wiring to an input port on a Remote Microphone Expansion Module Four circuit NAC module Class A or Class for boosters or control allows zone wiring separation Extensive non fire alarm features are available for night ringer tone telephone page input and background music Non fire alarm paging includes zone control and zone volume that are bypassed when the unit is in alarm mode Models are available for 120 VAC or 240 VAC input non voice FACUs require the addition of voice and tone Autocall 4003EC Emergency Communications Voice Control supply an extensive feature list Available equipment includes up 18 remote microphones up to 5000 W of distributed remote booster and extensive non fire alarm general paging controls operation requires opening the locked 4003EC cabinet door access the 8 message selection switches the local microphone and status indicator LEDs Secure control of remote microphones using a switch See Figure 4 applications Add audio operations to existing fire alarm control units or non audio Use of non emergency operations is suspended during battery operation and is overridden during emergency conditions This product was tested and approved by FM Approvals against both standard FM testing referenced to NFPA 72 and ANSI UL Standard 864 9th Edition Additional listings may be applicable your local Autocall product supplier for the latest status Refer to page 5 6 for CSFM models listed by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the Health and Safety Code See CSFM Listing 6911 2269 0577 for allowable values and or conditions concerning material presented in this document AC4003 0002 Rev 13 8 2021 Communication Systems and Mass Notification Systems voice control module features of pre and post audio tones can select pre message tones and if desired you can also select the same tone as a post message tone Tones are switch selected onboard and for each message pairs IN1 and IN2 message will have the same tone IN3 and IN4 message will have the same tone tones Temporal Pattern Bell a digitally recorded mechanical bell sound Temporal Pattern Horn 500 Hz tone Slow Whoop a slowly ascending tone Wail ascends then descends between 600 Hz to 940 Chime Tone Announcement Chime High Low with high frequency of 750 Hz for 100 ms and low frequency of 500 Hz for 400 GSA Tone continuous 2000 Hz Fast Whoop a quickly ascending tone Horn Tone at 120 beats per minute Horn Tone at 20 beats per minute Bell Tone at 60 beats per minute Pattern evacuation signal reference sec on 1 2 sec off 1 2 sec on 1 2 sec off 1 2 sec on 1 1 2 sec off digitally recorded messages Messages can be reproduced from high quality customer supplied audio professionally recorded to customer requirements or selected from the message library To order Custom Messages provide a CD or tape as appropriate a completed custom message questionnaire and include an English language Internal Order Processing Note Document this information using the FASTool configurator If supplied by a CD provide a WAV file format with 44,100 HZ and 16 bit mono Contact your local Autocall product representative for details Custom messages can be recorded at the control unit Locally recorded messages overwrite the pre recorded messages and external equipment is alarm operation features Addressable Paging Splitters Model A003 9845 allow non Alarm paging to be routed to zones as desired Supervised Volume Controls Model A003 9848 allow non Alarm paging and background music local volumes to be adjusted as desired during conditions the volume controls are bypassed This is not a Non Fire feature it was specifically developed for Fire ECS MNS Applications Telephone Zone Controller Model A003 9835 allows phone control selection of zones for background music or paging Night ringer telephone and security alert modes allow the 4003EC unit to provide system tones alerting of non alarm conditions needing attention In night ringer mode an externally mounted switch such as a doorbell switch can allow creation of a specific tone to alert a security guard who may be in normal hearing range of the daytime doorbell sound supply battery charger features Charges up to 33 Ah batteries up to 12 Ah batteries for cabinet mounting larger batteries are housed in a separate close nippled battery cabinet Green power on LED yellow trouble LED Earth fault detection battery supervision circuitry power loss and brownout voltage supervision 2 AC4003 0002 Rev 13 8 2021 Communication Systems and Mass Notification Systems messages and input priority list 1 Temporal Pattern evacuation signal reference 1 2 sec on 1 2 sec off 1 2 sec on 1 2 sec off 1 2 on 1 1 2 sec off Input t