Autocall Fire Alarm Network Annunciators; Fire Alarm Ethernet Switches

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Alarm Systems Alarm Network Annunciators Fire Alarm Ethernet Switches ULC CSFM Listed NYC Fire and FM Approved a dedicated Fire Alarm local area network LAN for of a TrueSite workstation server to remote clients Fire Alarm Ethernet Switches provide up to eight wired Ethernet with individual earth fault supervision Wired Ethernet cable distance of up to 328 ft 100 m Fire Alarm Ethernet Switches can be interconnected to extend capacity and or distance using either Ethernet wired ports fiber optic ports Fiber optic cable switch connections provides a distance of up to 1.24 2 km for multimode fiber and up to 9.3 miles 15 km for single Fire Alarm Ethernet Switches are UL listed to Standard 864 Switches are available without earth fault supervision for special not requiring fire alarm listings For additional TrueSite Workstation server and client information refer data sheet AC4190 0016 with three connection options Eight Ethernet wired ports with RJ 45 terminations Four wired ports and two single mode fiber optic ports SC connectors Four wired ports and two multimode fiber optic ports SC connectors faults are reported three ways An on board IDNet Supervised IAM is available for connection to a Autocall fire alarm control panel An on board trouble relay provides contact transfer On board LEDs identify fault location per port Alarm Ethernet Switches combine an Ethernet switch module with earth detection circuit for wired Ethernet connections housed a dedicated cabinet Using Fire Alarm Ethernet Switches allows of a TrueSite workstation server and multiple TrueSite clients into a dedicated Fire Alarm LAN When networked TrueSite workstation clients can monitor and if authorized control alarm system activity If additional connections or increased are required Fire Alarm Ethernet Switches can be connected additional switches Details Fire Alarm Ethernet Switch uses an Ethernet switching hub to bridge connected data links It also has the ability to segment the network in separate collision domains for network survivability Operation packets are inspected to determine the source and destination of each packet then forwarded accordingly Simultaneous exchanges are allowed on different data links resulting in more Operation is either half duplex or full duplex 1 Alarm Ethernet Switch Connection Reference Communications Support Ethernet Communication protocols include 10BASE T or 100BASE allowing network Ethernet connection speeds of 10 Mbps or 100 Models with fiber optic ports allow Fire Alarm Ethernet Switches be interconnected using the advantages of fiber optics connections optics ports operate at 100BASE FX Fault Detection an earth fault is detected by the Earth Detection Module it a general trouble for external monitoring Monitoring is by either communicating with the on board IDNet IAM or by the trouble relay contacts Earth fault status is indicated by the on board status LEDs see This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0543 and for allowable values and or conditions concerning material presented in this document NYC Fire Dept COA 6270 Additional listings may be applicable contact your local Autocall supplier for the latest status For specific product listings refer to tables 2 and 3 Rev 9 3 2021 Alarm Network Annunciators Fire Alarm Ethernet Switches Selection Ethernet Switch equipment and accessories are ordered as options for use with TrueSite Workstation and Incident Commander upper product selection model numbers per the System Order Reference section below For additional product information refer to data sheet for TrueSite Workstation and AC4190 0020 for TrueSite Incident Commander 1 System Order Reference to be selected per order type Workstation Standard Operation Workstation Fire Proprietary Supervising Station Incident Commander Annunciator Incident Commander Supervising Station Control Unit Workstation Remote Client Incident Commander Remote Client Hardware Additions wired Ethernet connections wired Ethernet connections and two single fiber optic connections 2 Fire Alarm Ethernet Switches agency listed for fire alarm 864 FM Each Server and Client LAN connection a A190 6010 Transient Suppressor for server to client connections when both in the same room see below for suppressor Ethernet Switch power shall be provided a listed fire alarm power supply Alarm Ethernet Switch VDC red cabinet with Detection on wired wired Ethernet connections and two fiber optic connections 3 Ethernet Switches not agency listed for fire alarm wired Ethernet connections wired Ethernet connections and two single fiber optic connections wired Ethernet connections and two fiber optic connections Switch only 6 W VDC 6 VA 8 24 VAC Power Adapter per below 864 Recognized component does not include detection module or cabinet 5 11 16 in x 7 3 8 in x 1 3 4 in 145 x 187 mm x 44.5 mm 4 Ethernet Switch Power Adapters select one for each A190 6051 A190 6056 or A190 6057 Power Adapters are NOT for with Fire Alarm Ethernet Switches A190 6050 A190 6054 or A190 6055 they require connection to a fire alarm power supply Mount Power Adapter with 6 1.8 m cord 120 VAC 60 Hz 20 W Output 24 VAC mA 240 VAC 50 Hz 78 mA Output 24 A650 mA Size in W x 2 15 16 in H x 1 7 8 in D 56 mm x 74 x 48 mm in W x 3 3 16 in H x 1 15 16 in D 58 mm x mm x 49 mm 5 Transient Suppressor for LAN WAN Connection for agency listing except for server to client connections that are in the same room mounts on rear of PC frame for or rackmount computers 2 Rev 9 3 2021 Reference additional information refer to Installation Instructions 579 903AC Alarm Network Annunciators Fire Alarm Ethernet Switches Arrangement shown for reference only Wiring pairs shown as one line for typical reference only The TrueSite Workstation and Incident PCs have 2 Ethernet ports For ES Network ES Net applications the ES Net NIC connection uses 1 Ethernet port leaving 1 Ethernet available for a connection to either an agency listed dedicated Fire Alarm LAN or a customer s LAN not both 2 Reference 3 Rev 9 3 2021 Alarm Network Annunciators Fire Alarm Ethernet Switches 6 Electrical Voltage Current VDC nominal from listed fire alarm power supply mA maximum C contact rated 0.3 A 125 VAC resistive 1 A 30 VDC resistive Power Trouble Relay Connections for Power IDNet and Trouble Relay Cable Connections Cable Data Rates Cable Wiring Distance Optic Cable Distance connection between Fire Alarm Switches Optic Cable Connections Detection Module Diagnostic LEDs Switch Module Diagnostic LEDs Specifications Range terminals for 18 to 12 AWG 0.82 mm2 to 3.31 mm2 jacks Mbps and 100 Mbps to 328 ft 100 m at 10 Mbps with Cat3 cable to 328 ft 100 m at 100 Mbps with Cat5 cable and Distance fiber up to 9.3 miles 15 km dB Details two fibers per Transmit and Multimode fiber up to 1.24 miles 2 km dB SC connectors LED LED Earth Fault LED On steady when an earth fault is detected on any of the when power is present to indicate IDNet communications are being received ports port has earth detection disabled LED is on steady Monitor Disabled one per Ethernet Port If port has earth detection enabled LED flashes to indicate that LED has an earth fault when power is present per port indicates a valid Ethernet link has been

Related Files