Autocall Fire Alarm Network Annunciators TrueSite Graphic Annunciator; Version 6 02; International
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-fire-alarm-network-annunciators-truesite-graphic-annunciator-version-6-02-international-3574182609.pdf |
---|---|
Type | |
Size | 8.24 MB |
Downloads |
Text Preview
UL ULC CSFM Listed Fire Alarm Systems Alarm Network Annunciators TrueSite Graphic Annunciators Version 6.02 with Autocall ES Net Network Graphic Annunciator general features RAID 1 Support provides a real time image on a secondary drive Operation will automatically transition to the alternate drive a drive failure without loss of operation RAID support is available to that do not use the Backup Utility Autocall fire alarm network connected graphical interface Supports standard fire service annunciation icons to provide and first responders with critical fire response information Custom alarm and system messages can intuitively guide responders important information including HAZMAT and contact information can be quickly presented Color graphical annunciation capacity for up to 250,000 ES Net points See ES Net Version Compatibility for additional details Floatable and dockable windows allows windows to either be fixed or floatable Password Security supports 8 to 16 alphanumeric passwords with lockout for quantity of failed attempts Pan and zoom features allow precise dynamic navigation within graphic screen for rapid and convenient selection of the area of Configurable coverage zones allow user defined areas or zones a graphics screen to be highlighted to indicate the area of without zooming into the point of interest Auto jump allows the screen view to automatically jump to a graphic a predetermined zoom level with the active device centered on the alternately the system can be selected to auto jump to the List window Captive or Non Captive modes support dedicated annunciator captive or annunciator operation with other Windows including word processing and spreadsheet where activity takes precedence non captive Extensive historical logging up to 500,000 events information compatible with spreadsheet and database programs for report Multiple password controlled operator levels with selectable feature Available optional connections for printers or other compatible Listings UL 864 as Fire Alarm Control Unit Annunciator UOXX S771 UL 1076 as Proprietary Burglar Alarm Unit APOU BP2801 UL 1610 as Central Station Burglar Alarm Control Unit AMCX S771 ULC ORD C1076 Proprietary Alarm System Annunciator APOU7 S771 UL 1076 Proprietary Burglar Alarm Multiplex Receiving Unit ULC S527 as Fire Alarm Control Unit Annunciator UOXX7 S771 annunciator system features Export to XML allows TrueSite Workstation data to be easily exported report generation and customization Node Name supports including a description of the specific building area associated with a point in the annunciator views and reports Web Browser Command Link enables the ability to easily call up an web page or link including web cam with a single command on a graphic screen 1 TrueSite Graphic Annunciator optional monitor with expanded desktop shown Backup Utility can be configured to automatically backup specified including TSW job data to the secondary hard drive The utility is available to systems that do not use RAID Sound files WAV can be used to create custom audible status using local onboard speakers Fahrenheit or Celsius temperatures can be displayed for screens heat sensor temperatures screens details is available for details Over 30,000 custom field generated and edited graphic screen Multiple import and export formats are supported refer to Graphics Fire Alarm Network capabilities Multiple annunciators can be nodes on the same fire alarm network to redundant operations for improved survivability Connect to up to seven 7 separate network loops Graphical diagnostic tools identify network node and loop status Provides event printing with compatible printer view or print of status service reports TrueAlert Self Test reports and print graphic see Table 16 for printing details Computers are available as desktop or rack mount with mouse and or touchscreen operation providing convenient user Desktop LCD widescreen high resolution LED backlit monitors are 24 class 23.8 in 605 mm diagonal provide 1920 x 1080 resolution are available with or without touchscreen Wall mount LCD widescreen high resolution monitors are 42 in 1067 diagonal provide 1920 x 1200 resolution and are available with without touchscreen Rack mount LCD high resolution monitors are 19 in 483 mm diagonal touchscreen and provide 1280 x 1024 resolution Annunciation Graphic Annunciators provide annunciation and status display Autocall Fire Alarm Networks using a personal computer based interface with a high resolution color display Operating Systems Compatible with Windows 7 10 Professional or computer and monitor options This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0543 7300 0026 0336 and 7165 2269 0542 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact local Autocall product supplier for the latest status AC4190 0022 Rev 20 11 2021 Alarm Network Annunciators TrueSite Graphic Annunciators Version 6.02 Image Reference Graphics not to scale When fire alarm network status changes occur the screen the type and location of the alarm or other activity and the header buttons appear In the historical log screen below in 7 Fire Priority 2 Supervisory and Trouble buttons are shown with active Trouble indicated Screens Figure 6 is representative of historical log screen Figure 7 is representative of a system graphic screen with representing the devices of interest Screen choices can be per system preference However when using multiple monitors multiple windows can be visible simultaneously for convenience of Operation With touchscreen monitors the operator touches screen area in alarm or uses the mouse control to access a more view of the alarmed zone or device With the proper password the operator has the ability to acknowledge alarm and trouble activate signal silence and perform system reset directly the workstation screens Activity Timeout allows an unattended monitor to to the login screen when the configured time period expires User Preferences appear when the user logs in Options Font Size default or large Toolbar Size small or large Theme MS Office 2003 or System Floating Window Options whether to show Menu bar or show Tool bar Log and List Details Figure 6 below shows historical log The display format is similar to the display for active list items as the alarm list Displayed information can be sorted on screen each category shown number time date point name etc List can be reviewed on the screen or printed at a local or system printer Response Custom alarm and trouble messages can be and field edited to provide operator response assistance Point information such as hazardous material storage and lists of to notify can be automatically or selectively displayed Control Access Levels Operator access level is determined during log Select functional access to match the training and responsibility of operator Operators with additional TrueSite Graphic Annunciator fire alarm network training may be qualified for access to more For operators who are primarily concerned with immediate facility a lower level access will provide the information necessary for response but will not allow access to areas beyond their training 2 24 in Desktop Monitor 3 42 in Monitor 4 Desktop PC 5 Rackmount 2 AC4190 0022 Rev 20 11 2021 Alarm Network Annunciators TrueSite Graphic Annunciators Version 6.02 Screens and Floor Plan Details Graphics screens can provide easily recognizable site plan and