UL ULC CSFM Listed System Peripherals Suppression System Abort Switches and Releasing Appliance Circuit RAC Switches switches provide a manual Fire Suppression System abort request Push button momentary switch is mounted on a stainless steel single systems require maintenance disconnect switches and often abort switches These abort and maintenance switches are labeled and combine easy operation with rugged construction for integrity operation plate if required A protruding collar protects the switch from accidental contact collar is Available flush or surface mount Flush mounting requires standard single gang box Surface mounting includes a red mounting box Models are available with internal 1.2 k resistor for current limited switches provide a secure and visible disconnect for servicing Fire Suppression System Releasing Appliance RACs Maintained position keyswitch with key removable only in the normal Disabled position opens connection to output circuit and places a 16.2 resistor across the input circuit to initiate a supervisory condition at host panel Models with indicator lamp use a bright incandescent bulb with red powered from separate 24 VDC Available for flush or surface mount Flush mounting requires a standard double gang box for models with or a standard single gang box for models without lamp Surface mount models includes a red mounting box Models with lamp provided with a double gang stainless steel plate without lamp provided with a single gang stainless steel plate listed to Standard 864 1 Switches with without Disconnect Indicator Lamp 2 Switch This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7300 2269 0555 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest status Rev 6 1 2020 Suppression System Abort Switches and Releasing Appliance Circuit RAC Maintenance Switches Selection mount mount includes red box Listed 1 Abort Switches Status size includes 3 position contact block housing with one block installed 2 Abort Switches for 4004R Series Suppression Release Panel Current Limited Operation size includes 1.2 k 1W for current limited operation 3 position contact block housing one contact block installed mount mount includes red box Status listed 3 Maintenance Switches with Disconnect Indicator Lamp mount mount includes red box Status ULC listed 4 Maintenance Switches without Disconnect Indicator Lamp mount mount includes red box Status ULC listed size includes 3 contact block housing with contact blocks installed disabled opens connection to and places a 16.2 k resistor the input circuit resistor is if required for retrofit size includes 3 position block housing with 1 contact installed disabled position connection to output and a 16.2 k resistor across the circuit resistor is removable if for retrofit 5 Accessories for Field Installation Contact Block for Abort or Maintenance Switch 1 Form C UL recognized component for use with these switches listings approvals are not applicable 2 Rev 6 1 2020 Suppression System Abort Switches and Releasing Appliance Circuit RAC Maintenance Switches Switch Installation Reference Red box is supplied with surface mount Abort Switch A2080 9057 or A2080 9068 3 Rev 6 1 2020 Suppression System Abort Switches and Releasing Appliance Circuit RAC Maintenance Switches and A2080 9060 Maintenance Switch Installation Reference 4 Rev 6 1 2020 Suppression System Abort Switches and Releasing Appliance Circuit RAC Maintenance Switches and A2080 9070 Maintenance Switch Installation Reference 5 Rev 6 1 2020 Suppression System Abort Switches and Releasing Appliance Circuit RAC Maintenance Switches Ratings Switch One Contact block Switch Control Contact all models Switch Lamp Contact Block A2080 9059 and A2080 9060 Switch Indicator Light A2080 9059 and A2080 9060 Switch with Current Limited Resistor Connections Switch Switch Information Ratings Range Range 6 Electrical Ratings contacts 1 N O 1 N C rated 2 A resistive 30 VDC control Silver contacts 1 normally open 1 normally closed rated 2 A resistive 30 VDC control Silver contacts 1 normally open 1 normally closed rated 2 A resistive 30 VDC 2 W incandescent bulb 24 to 30 VDC typical 83 mA 24 VDC requires separate 24 VDC 7 Wiring Connections blocks for in out wiring 18 AWG to 14 AWG wire 0.82 mm2 to mm2 blocks for first wire connection 18 AWG to 14 AWG wire 0.82 to 2.08 mm2 18 AWG wire lead for second wire connection AWG 0.82 mm2 color coded wire leads for suppression circuit blocks for lamp wiring 18 AWG to 14 AWG wire 0.82 mm2 to 2.08 Installation Instructions 8 Environmental Ratings to 120 0 to 49 to 93 at 90 32 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 6 1 2020

Related Files