Autocall Fireray One Beam Detector

File Preview
File Preview
Click below to download for free

File Data

Name autocall-fireray-one-beam-detector-3287594160.pdf
Type PDF
Size 872.71 KB
Downloads

Text Preview

UL ULC Listed CSFM Approved no specialist tools or knowledge needed for installation and the Fireray One is a standalone beam detector that prioritises of installation the Fireray One it could not be easier to bring the benefits of detection to your application One Minute Auto Alignment Just steer the laser onto the reflector at the flick of a switch it aligns itself eight times faster than detectors One person installation Everything can be done by one person One standalone product No specialist tools required minimal prior and training needed warehouses buildings Products One Beam Detector 1 Fireray One features One installation effective protection A standalone beam with all the of Fireray beam detection point of wiring and Movement automatically for natural movement to maintain when according to guidelines of the building cause other beam to misalign and in nuisance alarms 1 Fireray One 2 Fireray One 3 Reflector Listings are by Fire Fighting Enterprises Refer to CSFM 7260 1508 0500 This product was not approved by FM as of document revision date Rev 1 06 2021 One Beam Detector specification range method protocol Movement Tracking 2 Detection performance ft to 164 ft 0 m to 50 m ft to 394 ft 0 m to 120 m with Reflective Long Range Kit assisted Auto Alignment manual alignment optional setting check box search adjust and center for natural shifts in alignment from building movement when mounted according to guidelines for gradual build up of contamination on the optical surfaces for high levels of sunlight and artificial lighting compensation Cancellation Technology wavelength smoke detection 850 nm near infrared invisible nm visible Class IIIa 5 mW laser laser alignment beam detectors to be mounted facing each other with the reflectors in the middle Eliminates false Beam Phasing caused by crosstalk between beams alarm and fault relays VFCO 2 A at 30 VDC output response threshold levels to Alarm to Fault user interface status indication status indication distance between and Reflector path clearance spacing between detectors location dimensions x H x D dimensions weight arrangement color 3 Programmable user settings 1.25 dB Fastest response to smoke 1.87 dB Default value 3.46 dB High immunity to false alarms slow response to smoke 8.23 dB Highest immunity to false alarms slowest response to smoke through the integrated user interface seconds for momentary partial obstruction of the beam path seconds for momentary obstruction of the beam path 4 User features mode switch alignment directional buttons and configuration switches for alarm response threshold green LEDs and one yellow LED operation green LED flashing every 10 seconds condition red LED flashing every 5 seconds condition yellow LED flashing every 10 seconds for obscuration or every 5 seconds for contamination front face with enclosed optics Cleaning the optics does not affect alignment 5 Design parameters ft to 164 ft 5 m to 50 m ft to 394 ft 50 m to 120 m with Reflective Long Range Kit ft 1 m in diameter from center line between detector and reflector ft 18.3 m maximum as per NFPA 72 the ceiling jet flow top 10 of the floor to ceiling height unless otherwise stipulated in x 7.13 in x 5.28 in 130 mm x 181 mm x 134 mm see Figure 2 to 164.0 ft 50 m separation distance 3.94 in x 3.94 in x 0.36 in 100 mm x 100 mm x 9 mm to 393.6 ft 120 m separation distance Four reflectors 7.88 in x 7.88 in x 0.36 in 200 mm x 200 mm x 9 in square pattern 1.55 lbs 0.7 kg 0.22 lbs 0.1 kg Beam Phasing allows for detectors to face each other with the reflectors in the middle RAL9016 UV stable voltage current constant all operational modes 6 Electrical specifications VDC to 36 VDC operational modes 5 mA alignment mode 33 mA 2 Rev 1 06 2021 One Beam Detector gauge and type entry 7 Field wiring core dedicated 24 AWG to 14 AWG 0.5 mm to 1.6 mm compatible with fireproof and non fireproof cable meeting local installation standards knock out locations capable of accepting M20 1 2 in or 3 4 in glands drill out locations capable of accepting glands up to 0.82 in 21 mm diameter 8 Test and maintenance test alarm test using Commissioning and Maintenance Kit accessory 9 Environmental specifications temperature temperature humidity non condensing or icing rating flammability rating All figures are quoted for 77 25 to 131 20 to 55 to 185 40 to 85 to 93 V0 polycarbonate level rapid obscuration 2 seconds angular alignment of Reflective Detector angular misalignment of Reflective Detector angular misalignment of Reflector with adjustment bracket accessory 10 Optical specifications number 11 Ordering information One 164 ft 50 m detection range Long Range Kit 394 ft 120 m detection range and Maintenance Kit Detector Adjustment Bracket One Protective Cage Reflector Adjustment Bracket Reflector Adjustment Bracket Wall Bracket White Wall Bracket Black One Anti condensation Heater Anti condensation Heater One Back Box 4 Reflector Bracket 1031 000 5 Fireray One Box 1260 000 6 Protective 1100 000 7 Single Adjustment 1040 000 8 Long Kit 1010 000 3 Rev 1 06 2021 One Beam Detector 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 1 06 2021

Related Files