Autocall High Level Interface to VESDA Air Aspiration Detectors for 4100ES 4010ES Series Fire Alarm Control Panels
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-high-level-interface-to-vesda-air-aspiration-detectors-for-4100es-4010es-series-fire-alarm-control-panels-4081973256.pdf |
---|---|
Type | |
Size | 1.32 MB |
Downloads |
Text Preview
Datasheet Fire Alarm Systems Level Interface to VESDA Air Aspiration Detectors for 4100ES 4010ES Series Fire Control Units ULC CSFM Listed the Autocall VESDA High Level Interface HLI to provide between Autocall fire alarm control units FACUs and air aspiration smoke detection systems HLI enables communication of very low level smoke activity to critical or high value applications facilitating early response system communications include the following Smoke obscuration threshold levels Sample pipe network airflow status Detector head status Sensitivity settings detection unit features include the following You can program unit operation to recognize and categorize up to Information from up to 30 VESDA smoke detectors can be gathered on You can perform Reset Enable and Disable of each individual VESDA smoke levels communications input detector UL listing to Standard 864 with the following Autocall 4100ES and 4010ES FACUs VESDA E series models VEU VEP and VES VESDA models LaserPLUS VLP LaserSCANNER VLS LaserCOMPACT and LaserFOCUS VLF Laser Industrial VLI air aspiration smoke systems HLI Autocall VESDA HLI enables Autocall addressable fire detection units gather and process status information from VESDA high sensitivity air smoke detection systems Hardware requirements include an Interface Module installed in the fire alarm control unit and HLI Module and associated VESDA equipment installed in a separate warning combination of VESDA smoke detection and the extensive features the Autocall addressable unit equips mission critical and high value with a low level smoke detection system that can provide early of the presence of fire conditions 1 Autocall Control unit communicates VESDA smoke detection equipment with HLI Description air inlet Description link with VESDA Module 4100ES for reference level smoke in West cable tray Air Aspiration detection system data HLI and equipment 19 rack mount with box This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 2269 0542 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product supplier for the latest status AC4100 0026 Rev 8 12 2021 Level Interface to VESDA Air Aspiration Detectors for 4100ES 4010ES Series Fire Alarm Control Units the Autocall VESDA HLI communications link individual VESDA smoke detectors connect to the FACU as remote addressable devices This provides remote monitoring of the detectors locally displayed information and remote control for Reset Enable and Disable of the VESDA detectors interface applications critical or high value facilities require adequate protection from smoke and fire Some facilities have missions that are extremely critical or contents of high value and benefit from integrating very early smoke detection into their fire detection unit critical examples of mission critical facilities are telephone switching stations semiconductor clean rooms computer rooms and research laboratories such facilities loss of operation can result in significant economic impact value such as libraries archives and museums may contain priceless irreplaceable or high value objects that require extra protection the earliest indication of a potential fire condition the facilities need to dispatch trained personnel to investigate and repair wiring problems or malfunction In some instances saving a few seconds in response time may avoid extensive downtime or smoke damage to delicate or a priceless work of art interconnection information shown for reference communications link cable assembly with 4 1 2 ft 1.3 m leads supplied the Intelligent Interface Module mounted VESDA Intelligent Interface Module 4100ES module shown for reference Air Aspiration smoke detection system VSR 13D01 S04 VESDA HLI module and associated mounted in a 18 in rack with bok Includes VESDA programmer a VESDAnet socket and RS 232 for the FACU wiring four wire RD 232 compatible cable Total length maximum 20 ft 6 m 2 AC4100 0026 Rev 8 12 2021 Level Interface to VESDA Air Aspiration Detectors for 4100ES 4010ES Series Fire Alarm Control Units smoke detection summary VESDA air aspiration family of smoke detectors uses combinations of air intake air filtering high intensity laser photoelectric sensing and unique applications to provide early warning of incipient fire conditions By linking the analog output of a VESDA smoke detection system to compatible Autocall fire detection unit it is possible to identify those conditions before they become a problem Refer to the specific VESDA product for further details or an extensive list of features selection and reference model series number 1 FACU reference Interface Module mounted in FACU Each Intelligent Interface Module reduces the addressable communications channel capac by one IDNet communications 2 Xtralis VESDA smoke detector equipment reference VESDA HLI board a VESDA programmer and a VESDAnet socket all mounted in a 19 in equipment rack within a box to documentation supplied with the specific VESDA smoke detector equipment for additional specifications and smoke detection systems are supplied by Xtralis www xtralis com VESDA VESDA reference Requirement Listed Temperature Range Range 3 Autocall control unit mounted Intelligent Interface Module to 32 VDC from control unit mA 9600 baud maximum distance is 20 ft 6 m module requires 2 in internal rack width 51 mm F to 120 F 0 C to 49 C to 95 RH non condensing 4 HLI module VSR 13D01 S04 mounted in VESDA sub rack to 32 VDC from the VESDA smoke detector equipment mA 5 Installation instruction reference model series series model A100 6048 series model AC4010 9901 number 3 AC4100 0026 Rev 8 12 2021 Level Interface to VESDA Air Aspiration Detectors for 4100ES 4010ES Series Fire Alarm Control Units 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH the product names listed in this material are marks or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 8 12 2021