Autocall IAMs (Mini, Dual, Signal, and Relay); Monitor ZAMs, and Line Isolator Modules

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Technology Addressable Devices Mini Dual Signal and Relay Monitor ZAMs and Line Isolator Modules Technology addressable input output module features Mini IAMs Individual Addressable Module provide remote of a single input and have a small size suitable for mounting Dual Input IAMs provide remote monitoring of two Class B inputs or Class A input Relay IAMs provide remote relay contact control Signal IAMs combine with 24 VDC to provide a 2 A local Class B or A operation Notification Appliance Circuit NAC Monitor ZAMs Zone Adapter Module provide local Initiating Device IDC operation either dual Class B IDCs or single Class A IDC Line Isolator Modules monitor line condition and separates input output to isolate short circuits Address is easily programmed with the MX Service Tool Modules except A4090 5201 Mini IAM are mounted in a cover that provides access to the address setting port and allows of the LED status indicator Modules with covers mount in a standard dual gang MK box UL listed to Standard 864 For use with Autocall 4100ES 4010ES and 4100U Series fire alarm panels equipped with an MX Loop Module Refer to data sheet AC4100 0059 MX Loop Interface Modules for and 4010ES Fire Alarm Control Panels for MX Loop Module MX Technology addressable I O input output modules provide monitoring and control to satisfy a variety of applications Each individually addressable and communicates with an MX Loop Module in the host fire alarm control panel 1 Typical MX Technology I O Module Assemblies 1 Mini IAM Mini IAM Individual Addressable Module Features Small size for single input circuit monitoring of normally open or closed contacts Provides open and short circuit monitoring of the line Fits in small devices such as flow switches special detection devices explosion proof callpoints A variation of this module is used in addressable callpoints and pull Dimensions are 1 W x 2 5 H x D 48 mm x 58 mm x 13 mm If mounted separately from the device being monitored select box with cover plate per dimensions above 2 Dual Input IAM Dual Input IAM Features Two separately wired Class B spur inputs providing open and short line monitoring that can be combined for one Class A input Each can be configured to monitor normally open or normally closed Both inputs can be configured to initiate an alarm or short circuit fault in the event of a short circuit on normally open monitoring This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0506 7300 22690551 and 7165 2269 0542 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 3 1 2020 Mini Dual Signal and Relay Monitor ZAMs and Line Isolator Modules Monitor ZAM Zone Adapter Module Features Provides monitoring and zone power for two Class B circuits or one A circuit of low voltage conventional detectors and callpoints External 24 VDC power is supplied from a A100 5130 Voltage Module in the controlling host fire alarm panel 24 VDC status is monitored and a fault signal is provided if lost Power reset is controlled from the MX Loop module in the host fire panel Input detection circuit can be wired as one or two spur circuits Class or one 4 wire detection circuit 3 Relay IAM Relay IAM Features A single relay output programmable from the MX Loop Applications include signaling fire conditions to plant machinery fire dampers and security systems Relay coil is monitored Relay contact is rated for 2A 24V DC 4 Signal IAM Signal IAM Features Remote addressable NAC spur can be wired Class B or Class A and is 2A 24V DC for up to 62 appliances requires a separately wired VDC nominal input Can also be used to provide a supervised output for other control 6 Line Isolator Module Line Isolator Module Features Monitors the MX Loop line condition for short circuits and provides using solid state switches A spur circuit is connected between the input and output switches for convenience A fault on either the input Left side wiring or the output Right side opens that switch allowing the spur to continue to operate for circuits wired Class A and also isolates the shorted wiring section the functioning section A fault on the spur circuit opens both switches separating the spur the rest of the communications loop 5 Monitor ZAM 2 Rev 3 1 2020 and Installation Mini Dual Signal and Relay Monitor ZAMs and Line Isolator Modules 7 and bottom view reference modules A4090 5202 A4090 5203 A4090 5204 A4090 5205 A4090 5206 2 Addressable Input Output Modules supervised contact monitoring module Input IAM dual Class B or single Class A supervised contact monitoring module Class A monitoring requires EOL resistor IAM contact rated 2 A 24 VDC IAM two Class B NACs or one Class A NAC rated 2 A 24 VDC up to 62 appliances Class A output requires EOL resistor A4081 9022 Refer to the Installation Instructions for compatible notification appliances ZAM two Class B inputs or one Class A input Class A input requires EOL resistor assembly Regulated power is required the A100 5130 Voltage Regulator Module in the host panel Refer to the Installation Instructions for two wire detector compatibility information Isolator Module Selection 3 Rev 3 1 2020 k 1 W resistor Mini Dual Signal and Relay Monitor ZAMs and Line Isolator Modules 3 Accessories listed Four Wire End of Line Resistor Harness Assemblies provides two input and two output wire leads red black for in out wiring with an across the line resistor leads are 6 long mm with resistor and terminations insulated LED on single gang stainless steel plate optional for use with A4090 5201 Mini IAM Module Front Cover Service Tool ref MX Model 801AP Ancillary Program Lead Spare Service Tool Accessory Kit Monitor ZAM Loop Current Voltage from MX Loop from External 24 VDC not include detector cur Mini IAM Dual Input IAM and Relay IAM Signal IAM Isolator Module 4 Specifications voltage 24 VDC from A100 5130 Voltage Regulator Module in the host alarm control panel voltage 21.9 VDC voltage 26.4 VDC B standby 0.28 mA Class A standby 0.53 mA B standby 14 mA Class A standby 8.25 mA B or Class A alarm 50 mA per detector spur circuit detector voltage 18 VDC maximum detector voltage 25 V standby detector load per A4090 5205 2.8 mA Resistor for Class B spur circuits 4.7 k circuit resistance 50 mA in standby or in alarm without remote LED mA in alarm with remote LED mA in standby mA in alarm mA in standby mA in alarm mA in standby mA with single trip 10 mA with double trip fault on spur circuit box for each full size module not applicable to the Mini IAM resistance to monitored circuits Connections Temperature 2 gang MK box maximum blocks for wire size 20 to 14 AWG 0.5 to 2.5 mm2 to 120 0 to 49 to 93 RH at 90 32 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictl

Related Files