Autocall IDNet Addressable Devices Compatibility Chart

File Preview
File Preview
Click below to download for free

File Data

Name autocall-idnet-addressable-devices-compatibility-chart-9213745860.pdf
Type PDF
Size 673.90 KB
Downloads

Text Preview

UL ULC CSFM Listed FM communications compatibility chart 1 Devices compatible with 4007ES 4010ES and 4100ES IDNet communications Addressable Devices Communications Compatibility Chart B IDC ZAM A IDC ZAM A4098 9775 A4098 9776 Sensor Housing without Sensor Housing with relay Sensor Housing without relay Sensor Housing with relay wire Sensor Base with relay aspiration sensor housings 100 110 are single inlet 200 and are dual inlet 2 Devices with special considerations IAMs A4090 9051 is encapsulated and LED Address Sounder Base Address Standard Base Multi Sensor for above bases sensor Multi Sensor one address for photo heat TrueSense operation Temperature Heat Sensor Releasing Station Push Communications Isolator Signal IAM mA to 20 mA AMZ revision 2.01 firmware Contact Relay IAM A Relay IAM Base with LED relay output wire Sensor Base with supv Sensor Base Base Station Standard Station Breakglass Station Push Single Action Addressable 4010ES and 4100ES IDNet provide 4010ES and 4100ES IDNet two addresses does not provide TrueSense see below for single address applications A4098 9754 4010ES and 4100ES IDNet uses only address use with sensor bases A4098 9770 A4098 9780 A4098 9789 A4098 9792 A4098 9793 A4098 9776 A4098 9777 4098 9797 and 4098 9798 4010ES and 4100ES with IDNet Releasing FACUs only 4010ES and 4100ES IDNet 4010ES and 4100ES IDNet requires one but consumes two unit loads 4010ES and 4100ES IDNet IDNet requires unit loads 4010ES and 4100ES IDNet 4010ES and 4100ES IDNet Operation Beam Detector 4010ES and 4100ES 3 Devices compatible with 4007ES 4010ES 4100ES IDNet communications only except as noted IDNet NAC Extender 4009 A Fiber Optic Transmitter B A Repeater Message Board and 2 1 1 IAM Base Release Peripheral SRP without uses A2975 9227 with Enclosure This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 3240 2269 0526 7150 2269 0515 7150 0026 0224 7165 0026 0251 7165 2269 0514 7165 2269 0542 7260 2269 0572 7270 2269 0512 7272 2269 0509 7272 2269 0537 7300 2269 0508 7300 2269 0560 7300 2269 0503 7300 2269 0506 7300 2269 0507 7300 2269 0505 7300 2269 0555 7300 2269 0552 7300 2269 0553 7300 0026 0324 7300 0026 0330 and 7300 0026 0182 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local Autocall product for the latest status Rev 27 7 2021 1 1 1 1 1 1 3 3 3 1 1 1 Communications Compatibility Chart 4 Devices compatible with 4007ES 4010ES and 4100ES IDNet communications only except as noted Power Isolator IAM with T Sense Input IAM with unsupervised input Sensor Standard Base Hz Sounder Base Sensor Base with 520 Hz Sounder 1 1 1 1 Operation is software revision dependent see for software revision compatibility details for these products point Module four T Sense inputs two relays Monitor IAM two unit loads Not with 4007ES Mux Module internal IAM 4100ES only Sensor Sounder Base 1 1 1 Isolators and Isolator Bases are not compatible with the A100 3103 Quad FACU Mount Isolator Operation is compatible with other FACU that provide IDNet IDNet IDNet 1 IDNet 2 or IDNet 2 2 SLCs IDNet communications one address is assigned but the available SLC address count is reduced by 2 due to supervisory current Refer to individual product data sheets for listings information communications compatibility with devices in numerical order 5 Communications compatibility 4010ES and 4100ES IDNet see notes IDNet NAC Extender 4009A 120 VAC input IDNet NAC Extender 4009A 240 VAC input Repeater mounts in 4009A or 4009T only IAM with LED IAM Release Peripheral SRP no enclosure with Enclosure Signal IAM one address Contact Relay IAM A Relay IAM IAMs encapsulated w o LED B IDC ZAM B IDNet Fiber Optic Transmitter A IDC ZAM A IDNet Fiber Optic Transmitter Communications Isolator see note Power Isolator IAM with T Sense Input IAM with unsupervised input point Module four T Sense inputs two relays Monitor IAM two unit loads T sense Not 4007ES 2 unit loads T sense with 4007ES IDNet Isolators and Isolator Bases are not compatible with the A100 3103 Quad FACU Mount Isolator 6 Communications compatibility Temperature Heat Sensor Sensor Housing without relay Sensor Housing with relay sensor 4010ES and 4100ES IDNet see see Device communications chart 2 Rev 27 7 2021 6 Communications compatibility wire Sensor Base with supv relay Base remote LED or unsupervised relay wire Sensor Base remote LED or relay and supv remote relay Sensor Base Base see 4100ES note below Base Address Sounder Base for A4098 9754 Address Standard Base for A4098 9754 Sensor Standard Base Sensor Sounder Base Hz Sounder Base Sensor Base with 520 Hz Sounder Beam Detector Station Standard Station Breakglass Station Push Releasing Station Push Single Action Addressable Station Multiplex Module internal IAM mA to 20 mA AMZ revision 2.01 firmware surface mount mA to 20 mA AMZ revision 2.01 firmware flush mount Message Board Communications Compatibility Chart 4010ES and 4100ES IDNet see 4007ES 4010ES and 4100ES not 4007ES 4100ES only unit loads IDNet Isolators and Isolator Bases are not compatible with the A100 3103 Quad FACU Mount Isolator Multi point device point allocations Points and or sub points for mapping over the Network are designated as in the programmer For Table 7 through Table 12 refer to at the end of Table 12 for I O point usage and public points usage guidelines 7 4009 IDNet NAC extender 4009A type IDNet NAC Extender 120 VAC input IDNet NAC Extender 240 VAC input 4 circuit NAC added to A009 9201 or 4010ES and 4100ES point usage1 1 for each NAC 1 for each NAC points usage2 to 5 1 for each NAC 1 for to 9 1 for each NAC 1 for 8 Addressable I O devices type IAM with T Sense Input IAM with feedback unsupervised Module 4 T Sense inputs 2 relays 4010ES and 4100ES point usage1 1 for relay 1 for input 1 point for each Relay IAM points usage2 to 3 1 for relay 1 for input 1 for 1 for each relay 1 for each to 7

Related Files