Autocall IDNet Communicating Devices A4090-9101 and A4090-9106, Zone Adapter Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-idnet-communicating-devices-a4090-9101-and-a4090-9106-zone-adapter-modules-8925341076.pdf |
---|---|
Type | |
Size | 882.61 KB |
Downloads |
Text Preview
Datasheet Peripherals Communicating Devices A4090 9101 and A4090 9106 Zone Adapter Modules Monitor ZAMs Monitor ZAMs allow a single addressable point to monitor a initiating device circuit IDC populated with 2 wire or 4 initiating devices Refer to Monitor ZAM Two Wire Initiating Device Reference Chart for compatible devices ULC CSFM Listed FM communications compatible Monitor ZAMs Zone Adapter provide an addressable interface to a conventional device circuit IDC for Class B or Class A IDCs A4090 9101 Class B monitoring for 2 wire or 4 wire initiating devices power reset connections for 4 wire devices A4090 9106 Class A monitoring for 2 wire initiating devices Zone device power is supplied separately typically from fire alarm panel Refer to device compatibility list Monitor ZAM Two Wire Initiating Compatibility Reference Chart use with the following Autocall fire alarm control panels Model Series 4007ES 4010ES and 4100ES fire alarm control panels IDNet communications sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 in 102 mm square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after UL listed to Standard 864 1 Series ZAM Package approximately 1 2 size This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0508 7270 2269 0511 7272 2269 0510 7270 2269 0513 7300 2269 0507 and 7300 2269 0567 for allowable values and or conditions concerning material presented in this document listings may be applicable contact your local product supplier for the latest status Rev 6 03 2021 Communicating Devices A4090 9101 and A4090 9106 Zone Adapter Modules Input Voltage Current 24 VDC ZAM Zone Supervision Resistor Connections Wiring Material Plate Material Range Range Selection 1 Specifications 1 address per device to 32 VDC nominal 24 VDC 16 mA maximum Alarm 72 mA maximum actual current is by total device requirements k 1 W terminals for in out wiring 18 to 14 AWG wire 0.82 to 2.08 mm2 to 2500 ft 762 m from fire alarm control panel to 10,000 ft 3048 m total wiring distance including T Taps with Autocall A2081 9044 Overvoltage Protectors 1 8 in H x 4 1 8 in W x 1 3 8 in D 105 mm x 105 mm x 35 mm thermoplastic metal galvanized to 120 F 0 to 49 C intended for indoor operation to 93 RH at 100 F 38 C 2 ZAM Modules Adapter Module for Class B monitoring of 2 wire or 4 wire initiating devices with power reset connections 4 wire devices Adapter Module for Class A monitoring of 2 wire initiating devices 3 Optional Adapter and Trim Plates plate to fit 4 11 16 in 119 mm square electrical box semi flush mounted box surface mounted box 4 End of Line Resistor Harness plate with LED viewing includes mounting screws steel No k 1 End of Line Resistor Harness for A4090 9101 Class B zone 2 Rev 6 03 2021 Communicating Devices A4090 9101 and A4090 9106 Zone Adapter Modules ZAM Two Wire Initiating Device Compatibility Reference Chart Bases Quantity heat detectors base required smoke detectors detector housing with A4098 9601 detector Four wire detector operation is compatible with conventional listed contact closure initiating devices Four wire detectors require detector voltage to be connected to resettable power terminals Refer to installation instructions 574 183AC and field wiring diagram 842 073 for additional information Contact your local Autocall product supplier for additional compatible devices 3 Rev 6 03 2021 Communicating Devices A4090 9101 and A4090 9106 Zone Adapter Modules Mounting Information mounting of the A4090 9101 A4090 9106 ZAM The A4090 9801 Trim plate for semi flush mounted boxes and the A4090 9802 trim plate for mounted boxes are also illustrated 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 6 03 2021