Autocall IDNet Communicating Devices, Individual Addressable Modules (IAMs)

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Peripherals Communicating Devices Individual Addressable Modules IAMs 1 Supervised IAM 2 Supervised IAM Closure of the monitored contact s initiates an alarm or other response programmed at the fire alarm control panel An open in the circuit wiring will cause a trouble to be reported Selections can be made at the control panel to maintain the alarm if the initiating device contacts are momentary such as from a heat detector or to track the device contact status Limited Operation Applications use with IDNet communications only these IAMs can provide quad sensing of normal open circuit short circuit and current limited Program type is T sense With the proper end of line and limiting resistors dual functions such as tamper switch and switch monitoring can be determined and communicated by a addressable point ULC CSFM Listed FM addressable communications supply both data and power a single wire pair to provide Supervised Class B monitoring of normally open dry contacts Total wiring distance from IAM to supervision resistor s of up to 500 ft m Monitored connection is compatible with Autocall A2081 9044 Protectors for outdoor wiring or electrically noisy For use in indoor locations up to 158 F 70 C such as attic spaces or applications use with following Autocall control panels Model Series 4007ES 4010ES and 4100ES fire alarm control panels for communications A4090 9001 Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after requires mounting bracket ordered separately A4090 9051 Encapsulated design for extended exposure to high humidity LED is present on this model Color coded 18 AWG leads for wiring communications provides current limited monitoring Provides monitoring of tamper switch supervisory and waterflow alarm on same circuit using one point Available with IDNet communications only operation modes are available and are selectable at the panel Contact closure status can be tracked Momentary contact closure conditions can be selected at the panel to latched or tracked UL listed to Standard 864 listed to Standard 864 addressable modules IAMs both power and communications from a two wire IDNet circuit provide location specific addressability to a single initiating device as single station smoke detector alarm contacts or heat detector or multiple devices at the same location by monitoring open dry contacts and the wiring to an end of line resistor A4090 9001 is packaged in a thermoplastic housing and provides screw connections and a status indicating LED A4090 9051 is an encapsulated package with wire leads It does not a status indicating LED This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0507 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 14 03 2021 Communicating Devices Individual Addressable Modules IAMs 1 IAM Product Selection IAM mounted in thermoplastic housing with screw terminals see applicable options below IAM encapsulated with wire leads 2 Optional Trim Plates and Mounting Bracket for Model A4090 9001 semi flush mounted box plate with LED viewing window A4090 9810 mounting bracket surface mounted box mounting screws galvanized steel bracket mounts IAM to electrical box and provides screw holes for trim plate required for trim plates 3 End of Line Resistor Harnesses ordered separately as required no k 1 2 W Standard end of line resistor harness for N O contact supervision k 1 2 W k 1 2 W for current limited monitoring 4 Electrical auto selected 1 address per IAM open dry contacts terminals for in out wiring 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 coded wire leads 18 AWG 0.82 mm2 8 long 203 mm for A4090 9001 579 572AC for A4090 9051 for IDNet operation Instructions Wiring Diagrams Product Selection and Communications Requirements Connections Documents from IAM to Contacts Distance Reference per channel IDNet Communications Material A4090 9001 Material A4090 9051 Range Range 5 Wiring Distances ft 152 m maximum without protectors ft 122 m maximum with A2081 9044 Overvoltage Protectors ft 762 m maximum from fire alarm control panel ft 3048 m maximum total wiring distance including T Taps 6 Mechanical W x 1 3 4 H x 1 1 4 D 40 mm x 44 mm x 32 mm W x 1 9 16 H x 9 16 D 40 mm x 40 mm x 14 mm thermoplastic beige to 158 F 0 to 70 C intended for indoor operation to 93 RH at 100 F 38 C 2 Rev 14 03 2021 Information Communicating Devices Individual Addressable Modules IAMs 3 Reference Single Gang Blank Cover Plate 3 shows A4090 9001 IDNet supervised IAM 4 Trim Plates and Mounting Bracket for Visible LED 4 shows the following A4090 9806 Trim plate for semi flush mounted box A4090 9807 Trim plate for surface mounted box A4090 9810 Mounting bracket ordered separately 3 Rev 14 03 2021 Mounting Information Communicating Devices Individual Addressable Modules IAMs 5 shows a A4090 9051 Encapsulated Supervised IAM 5 Mounting Information 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 14 03 2021

Related Files