Autocall IDNet Communicating Devices Model A4090-9002 Relay IAM

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Addressable Relay Module Relay IAM IDNet addressable control for use with Autocall fire alarm control panel 4007ES 4010ES and 4100ES A single addressable point provides control and status tracking of a contact Low power latching relay design allows IDNet communications to both data and module power Relay is set to OFF on initial power up and upon loss of IDNet sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 in 102 mm square electrical box optional bracket is available to mount in a 4 11 16 in 119 mm square box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after listed to Standard 864 Peripherals Communicating Devices Model A4090 9002 Relay IAM Selection 1 Product Selection IAM 2 Optional Adapter and Trim Plates plate to fit 4 11 16 in 119 mm square box semi flush box surface mounted Plate galvanized steel with viewing window includes screws 3 Specifications communications 1 address per device by IDNet communications IAM Power Ratings not rated for incandescent switching C SPDT A 24 VDC resistive A 24 VDC inductive A 120 VAC resistive listed fire supply Provide circuit fusing and transient suppression as required per DC inductive loads can typically be diode suppressed 120 loads may require RC networks or varistors depending on device Refer to the installation instructions for additional information Connections Communications Reference Material Plate Range terminals for in out wiring 18 to 14 AWG 0.82 to 2.08 mm2 to 2500 ft 762 m from control panel to 10,000 ft 3048 m total wiring distance T Taps with Autocall A2081 9044 Protectors 1 8 in H x 4 1 8 in W x 1 3 8 in D 105 mm x mm x 35 mm thermoplastic metal galvanized to 120 F 0 to 49 C intended for indoor to 93 RH at 100 F 38 C Range Instructions 574 184AC 1 IDNet Relay IAM shown approximately 1 2 size Relay IAMs allow fire alarm control panels to control a remotely Form C contact using IDNet addressable communications both data and module power Typical applications would be for local power for control functions such as elevator capture or of HVAC components pressurization fans dampers etc Relay is also communicated requiring only one device address This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0507 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 12 03 2021 IAM Mounting Information illustration shows the mounting of the A4090 9002 Relay IAM Also shown are the A4090 9801 trim plates for semi flush mounted boxes and the trim plate for surface mounted boxes Communicating Devices Model A4090 9002 Relay IAM A4090 9002 Relay IAM shown above A4090 9801 Trim plate for surface mounted box shown above 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 12 03 2021

Related Files