Autocall IDNet Communicating Devices Model A4090-9008 Dual Contact Relay IAM

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Initiation Peripherals Communicating Devices Model A4090 9008 Dual Contact Relay IAM Contact Relay IAMs allow fire alarm control panels to control remotely located Form C contact using IDNet addressable for both data and module power Typical applications be for switching local power for control functions such as elevator or control of HVAC components pressurization fans dampers Relay status is also communicated requiring only one device adapter for semi mounted box adapter for surface box 1 Product Selection trim plate for 4 boxes LED viewing window includes screws galvanized steel Firmware Connections Reference 2 General Specifications communications 1 address per device by communications 3.12.04 or higher terminals for in out wiring 18 to 14 AWG 0.82 to 2.08 mm2 to 2500 ft 762 m from control panel to 10,000 ft 3048 m total wiring distance T Taps with Autocall A2081 9044 Protectors H x 4 W x 1 D mm x 102 mm x 35 mm metal galvanized Plate Range 32 to 120 F 0 to 49 C intended for indoor Range to 93 RH at 100 F 38 C 3 Contact Ratings not rated for incandescent switching Form C contacts DPDT with terminal access to Common N O and N C for each A 30 VDC resistive A 30 VDC inductive listed fire supply contact common is fused with a 2 A fast non time delay fuse 0.5 A 125 VAC resistive Fusing Provide external transient suppression as required per DC inductive loads can typically be diode suppressed 120 loads may require RC networks or varistors depending on device Refer to Installation Instructions for additional information 1 Dual Contact Relay IAM Contact Relay IAM Individual Addressable Module A single addressable point provides control and status tracking of two A Form contacts Low power latching relay design allows IDNet communications to both data and module power Relay is set to OFF on initial power up and upon loss of IDNet use with following Autocall control panels Model Series 4007ES 4010ES and 4100ES fire alarm control panels for communications construction Mounts in standard 4 102 mm square electrical box optional bracket is available to mount in a 4 11 16 square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications can be selected at to indicate activated state Optional 4 square box covers are available to allow LED to be viewed installation listed to Standard 864 Selection 1 Product Selection Contact Relay IAM adapter plate to fit 4 11 16 119 mm square box This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0505 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 5 03 2021 Communicating Devices Model A4090 9008 Dual Contact Relay IAM Contact Relay IAM Mounting Information Contact Relay IAM Mounting Information shows the procedure for mounting the A4090 9008 Dual Contact Relay IAM Assembly to the Adapter Plate Also shown are the optional A4090 9801 Trim Plate for semi flush mounted boxes and the A4090 9802 Trim Plate for mounted boxes 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 5 03 2021

Related Files