Autocall IDNet Communicating Devices Model A4090-9010, 8 A Relay IAM
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-idnet-communicating-devices-model-a4090-9010-8-a-relay-iam-6209584317.pdf |
---|---|
Type | |
Size | 1021.61 KB |
Downloads |
Text Preview
Datasheet Peripherals Communicating Devices Model A4090 9010 8 A Relay IAM 2 Optional Trim Plates and Adapter For semi flush mounted For surface mounted Adapter plate to fit 4 11 16 119 mm square electrical box plate galvanized steel with viewing window includes screws 4 Contact Ratings not rated for incandescent switching IAM Power Voltage Ratings Connections Reference 3 Specifications communications 1 address per device by IDNet communications contacts 1 NO and 1 NC VAC or 30 VDC A resistive A inductive at 0.35 PF terminals for in out wiring 18 to 14 AWG 0.82 to 2.08 mm2 to 2500 ft 762 m from control panel to 10,000 ft 3048 m total wiring distance T Taps with A2081 9044 Overvoltage H x 4 W x 1 D 105 mm x 102 mm x 35 metal galvanized Plate Range 32 to 120 F 0 to 49 C intended for indoor Range Provide circuit fusing and transient suppression as required application DC inductive loads can typically be diode suppressed VAC loads may require RC networks or varistors depending on type Refer to Installation Instructions for additional information to 93 RH at 100 F 38 C ULC CSFM Listed FM 1 8 A IDNet Relay IAM Package Addressable Relay Module Relay IAM A single addressable point provides control and status tracking of 8 A Normally Open Form A NO and 8 A Normally Closed B NC contacts Low power latching relay design allows IDNet communications to both data and module power Operation upon loss and restoration of communications is switch to either reset the output relays to normal or to keep them in the selected state use with following Autocall control panels Series 4007ES 4010ES 4100ES fire alarm control panels for communications construction Mounts in standard 4 102 mm square electrical box optional bracket is available to mount in a 4 11 16 square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications can be selected at to indicate activated state Optional 4 square box covers are available to allow LED to be viewed installation listed to Standard 864 A Relay IAMs allow fire alarm control panels to control a remotely NO and NC contact using IDNet addressable communications both data and module power Typical applications would be for local power for control functions such as elevator capture or of HVAC components pressurization fans dampers etc Relay is also communicated requiring only one device address Selection A Relay IAM 1 Communicating Device This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0505 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 3 03 2021 A Relay IAM Mounting Information Communicating Devices Model A4090 9010 8 A Relay IAM 2 A Relay IAM Mounting Information 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 3 03 2021