Autocall InfoAlarm Command Center for the 4100ES Fire Alarm Control Panel discontinued

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed NYC Fire Approved with Autocall ES Net Fire Alarm Networks expanded content display interface for Autocall 4100ES fire alarm control units available with the following Fire alarm control units stand alone or networked including CPU options Software Revision 12 or higher is required Network Display Units NDU with support for up to 12,000 points Remote Annunciator panels and models that mount in a dedicated 4100ES control units support Remote InfoAlarm Command independent of host panel display type UL listed to Standard 864 Command Centers provide customized operating Activity in System primary display choices include First and Most First 5 and Most Recent First 8 Site Plan with activity status General Alarm or Direct to List selectable individually by event System reports are easily viewed logs can be read with minimal required Up to six softkeys per screen provide functions that vary with the screen information aiding operators to determine how to Up to two languages are available per system easily selected by key press systems with IMS GCC NPU or 2 x 40 LCD or annunciators require one language to be the default font International models allow customized language legends for operator and status LEDs by point Information sent to Remote InfoAlarm Command Centers can be properties 320 x 240 dot matrix QVGA display provides an active area of 4.53 x 3.4 H 115 mm x 86 mm displaying up to 854 characters using ASCII character font Bright white LED backlighting provides efficient and long lasting operation is selectable as continuous or off with power fail with no key presses 320 x 240 dot matrix QVGA display provides an active area of 4.53 x 3.4 H 115 mm x 86 mm displaying up to 854 characters using ASCII character font Command Center Control Unit LCD interface requires key presses to access detailed information By using a larger format instead of an individual text line display the LCD provides information for Alarm Supervisory or Trouble The format can customized per application allowing additional information to be to suit the specific application Fire Control Units Command Center for the 4100ES Fire Alarm Control Unit 1 Command for Control Unit Mounting 2 Command Center in Remote Cabinet Command Centers for 4100ES fire alarm systems provide large display with extended information content dual language including 2 byte character languages and an intuitive control interface per the following Up to 10 InfoAlarm Command Centers are supported per 4100ES unit able to allow one InfoAlarm Command Center to take and to designate access levels for interfaces not in control can be programmed for in control status indications Menu driven format conveniently prompts operators for the next required Key controls are provided to select the highlighted entry load next of information or jump to top or bottom of activity lists Direct point callup displays individual points alphabetically and then in on the logical choice as more point information is entered A Site Plan bitmap can be displayed for reference icons can be added indicate system status Up to 50 custom point detail messages can be generated Date formats are either MM DD YY or DD MM YY Time formats are either 24 hour or 12 hour with AM PM System Normal screen supports a gray scale bitmap watermark for name company logo or site plan This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7120 2269 0546 7120 2269 0547 7165 2269 0542 for allowable values and or conditions concerning material presented in this document NYC Fire Dept COA 6271A Additional listings may be applicable contact your local supplier for the latest status Rev 16 8 2020 documentfirealarmresources com Command Center for the 4100ES Fire Alarm Control Unit 3 Plan Trouble Log History screen shown to the right identifies the ability to multiple event entries with minimal scrolling For specific information pressing Next or Previous on the keypad highlights the selected or previous item in the list as indicated by the arrow and the bolded line of Entry 6 See Figure 4 access to the next or previous full screen of information use the Page or Page Up keys located to the right of the soft keys each to the right the display Plan with Event Icons Plan Bitmap The InfoAlarm Command Center supports a site plan bitmap image size is 281 pixels wide by 192 pixels high can also display icons indicating activity and location Shown to the is a sample site plan with icons shown in each building area For this each area is showing an A for an initiating device in alarm a for waterflow occurring and an icon indicating notification appliances alarm Icons can be created for site specific symbology these are for only Plan Selection and Detail If desired the site plan can be the display screen for system activity or can be for reference available selecting the Site softkey Depending on the facility layout the site can also be a convenient location for common reference information as primary call phone numbers street address etc to assist in their assigned response Normal Screen The site plan or another bitmap image can displayed on the System Normal screen as a grey image watermark the screen text Size and type are the same as that for a site plan This can be used to identify the specific location of the 4100ES or display a site specific logo or other information Review 4 Log Emphasis Main Menu screen illustration to the left demonstrates how print statements appear for status information or for prompting of user Other examples of this format occur when setting time and date a password or identification of a status change such as point or disabling Use of this feature allows the display to clearly focus user on required information or actions Primary Display Screens are samples of a First and Most Recent primary display and of a General Alarm display 5 Menu 6 and Most Recent Primary Display Option 7 Alarm Primary Display Option 2 Rev 16 8 2020 documentfirealarmresources com Unit Operation Reference Detailed operator instructions are on document 579 685AC Command Center for the 4100ES Fire Alarm Control Unit 8 Unit Operation Reference 3 Rev 16 8 2020 documentfirealarmresources com Feature Reference Command Center for the 4100ES Fire Alarm Control Unit 9 Feature Reference 4 Rev 16 8 2020 documentfirealarmresources com Display Details Command Center for the 4100ES Fire Alarm Control Unit InfoAlarm Command Center Front View 10 Display Details 11 InfoAlarm Command Center Front View 5 Rev 16 8 2020 documentfirealarmresources com InfoAlarm Command Center Mounting Reference Command Center for the 4100ES Fire Alarm Control Unit 12 InfoAlarm Command Center Mounting Reference 4100ES and ES Net Product Reference 1 Additional 4100ES and ES Net Product Reference DACT SDACT for 4100ES 4010ES 4007ES and Battery Cabinet Reference for 4100ES Ah Batteries and Cabinets for 4100ES Battery Brackets Reference 110 Ah Battery Charger for 4100ES 4010ES Basic Units with SPS Power Supplies LED Switch Modules Printer Emergency Voice Alarm Equipment Enclosures Net Network Products and Specifications with SPS Power Supplies for ES Net Basic Units with EPS Power Supplies Command Center with EPS Power Supplies with EPS Power Supplies for ES Net 6 Rev 16 8 2020 documentfirealarmresources com Command Center for the 4100ES Fire Alarm Control Unit Selection data sheet for descriptions of the 4100ES Basic Control Unit details standard product features options and reference for related fire alarm unit products

Related Files