Autocall LED Text Messaging Appliance with Addressable Message Selection using IDNet Communications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-led-text-messaging-appliance-with-addressable-message-selection-using-idnet-communications-6854013927.pdf |
---|---|
Type | |
Size | 7.97 MB |
Downloads |
Text Preview
UL ULC CSFM Listed ES Fire Control Units Text Messaging Appliance with Addressable Message Selection using IDNet 1 TrueAlert Text Messaging Appliance with sample evacuation message plan on page 4 visibility multi color LED text message board provides visible textual alarm notification controlled from compatible Johnson fire alarm control units During alarm conditions up to 32 pre programmed message selections can be activated in response to pre defined emergency situations or linked specific system point status conditions Text messages provide textual alarm notification for areas of high noise or with other audibility limitations Text messages can duplicate a broadcasted audible message or can provide more local detail per the Emergency Communication Systems Mass UL listed to Standard 1638 Textual Visible Appliance ULC listed to S527 Miscellaneous Ancillary Device Refer to ULC note in message specifications with the 4007ES 4010 4010ES 4100ES and 4100U Series fire alarm control unit using IDNet communications IDNet communications format emulates 4009 IDNet NAC Extender 4009A controls for easy interfacing 4007ES 4010ES 4100ES and 4100U IDNet SLCs signaling line circuit can control up to 25 message boards with up to ten 4009 IDNet NAC 4010 IDNet SLCs control up to five total of either type message presentation area provides long distance wide area 140 viewing Dual line 2.3 in 58 mm high messages provide typical viewing distance of up to 100 ft 30.5 m Single line 4.7 in 119 mm high messages provide typical viewing distance of up to 200 ft 61 m LEDs are multi color red yellow green to emphasize message content Words can be upper or lower case standard bolded condensed or expanded with selectable sizes Messages can be static flashing or scrolling with a variety of appearance transition options communications control provides Up to 32 available messages 10 factory pre programmed messages are included message details Advise of proper evacuation routes relocate to a secure area take action due to severe weather conditions defend in place or other facility specific New messages can be created factory pre programmed messages can be modified if needed Please note that the creation and modification of alarm messages may trigger code mandated retesting of the fire alarm system and should be by authorized service personnel non alarm general messages can be created using TrueSite Workstation Free Form Messaging Software requirements Message board is powered by listed fire alarm power supply providing 24 VDC with battery backup typically provided by host control unit features Standard message board includes fixed brackets for wall mounting and also includes 100 mm VESA Video Electronics Standards Association holes for use with listed wall or ceiling VESA mounting bracket Optional wall mount adjustable brackets allow rotation downward where required for improved viewing Optional mounting box secures to wall surface or flush can also mount with 100 mm VESA bracket Ceiling mounting is available by cable suspension connected to top mounted eyehooks optional operation mode Message boards can also display general non alarm information via local LAN Ethernet connection created using TrueSite Workstation Free Form software general free form messaging is overridden during an Alarm or Alert condition Control units will override non alarm messages upon alarm they can also be programmed to blank the display during local power failure to conserve product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7300 0026 324 for allowable and or conditions concerning material presented in this document It is subject to re examination revision and possible cancellation Additional listings may be applicable contact your local Controls product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Johnson Controls International Rev 1 6 2021 Text Messaging Appliance with Addressable Message Selection using IDNet Communications messaging appliances Audible appliances and strobes are commonly used to provide notification of alarm conditions typically to signal the for building evacuation However when the required response is to relocate defend in place or provide detailed information TrueAlert Text Appliances display custom text messages with the instructions required per the local emergency communication systems mass notification mode When alarm conditions occur the fire alarm unit overrides optional non alarm messaging and selects the programmed messages pre to be appropriate for the reported conditions In multiple alarm situations up to 8 messages can be displayed in sequence and date optional If desired the TrueAlert Messaging Appliance can be configured to display time and date obtained from an SNTP server the facility Ethernet network messaging optional Fire detection systems configured with a TrueSite Work Station TSW are capable of sending custom free form of up to 100 characters to 4907 9007 displays that are on the same Ethernet network Free form messaging is a discrete application that on TSWs equipped with Microsoft Windows 7 and Windows 10 operating systems Alarm messages will always take priority over any free general messages being displayed You can upgrade TSW that were not factory configured with the free form messaging application by the software from the appropriate JCI website communications optional The 4907 9007 TrueAlert Messaging Appliance can receive emergency messages from cloud based notification platforms such as e2campus or Rave Mobile Safety Using these services the sign queries the emergency notification platform messages These emergency notification service platforms provide a web interface that enable a local authority a chief of police for example to log on their PC and send dynamic messages to a portal for transmission to various device types including the 4907 9007 display Note that a customer have an account with an emergency notification service to employ this capability monitoring optional Authorized users can check the configuration and operating status of 4907 9007 displays from a web browser by support inovasolutions com using the support account that is included with each message board Remote monitoring can be configured to email alerts to be issued in the rare event that one or more 4907 9007 displays lose time synchronization or becomes non responsive failure mode The host fire alarm unit can be programmed such that during a local power failure the blanking message is sent to reduce standby requirements In the event of an alarm condition during power failure the panel will use its battery backup to fully power the appliance display the appropriate messages control process The compatible fire alarm control panel activates the Messaging Appliances by sending IDNet communications commands to those used to control the 4009 IDNet NAC Extender Commands include control of up to 8 NACs and with each NAC capable of up to 4 control modes resulting in a total of 32 commands available to select custom messages and the blanking control 2 TrueAlert Text Messaging Appliance with sample initiate lockdown message 3 TrueAlert Text Messaging Appliance installed in building 2 Rev 1 6 2021 Text Messaging Appliance with Addressable Message Selection using IDNet Communications selection Messaging Appliance in dark gray housing supplied with fixed mounting brackets for wall mounting includes for VESA bracket mounting or for ceiling cable mounting optional Adjustable Swivel Mount Brackets to allow wall mounted appliance to be tilted down where desired Ethernet Cable 15 ft long 4.6 m connect for non fire alarm messaging input Mounting Box lightweight aluminum painted dark gray 30 5 16 in W x 6 3 4 in H x 1 3 8 in D shipped with for attaching messaging appliance refer to Table on page 4 pre programmed messages Title sec Threat Message The top line is yellow and fixed the bottom line is red and scrolling Line Line sec Intruder sec in Place sec Exit sec Weather sec Clear sec sec sec sec Voice Line Line Line Line Line Line Line Line Line Line Line Line Line Line Line Line Lines