UL ULC CSFM Listed FM additional remote microphones to a Autocall 4100ES fire audio control panel Each A100 1274 Microphone Multiplex Module converts a single input to support up to eight 8 remote microphones Up to 40 remote microphones can be connected per audio controller compatibility below Allows additional remote microphones for applications such as UFC Facilities Criteria requirements for Mass Notification systems Navy and Air Force requiring a microphone interface within 200 ft m of travel within a building Refer to UFC 4 021 01 9 April 2008 for details Note Remote and associated controls have specific operation and requirements per this document Connect one 1 A100 1274 to the remote microphone input of either Digital Audio Controller Model A100 1311 or an Analog Audio Model A100 1210 Connect up to two 2 A100 1274 Microphone Multiplex Modules to a Auxiliary Audio Input Module inputs 3 and 4 Up to two 2 A100 1240 modules are supported per audio controller microphones Model A100 1244 panel mounted microphone located in Remote Model A4003 9803 remote microphone with control requires wiring to a 24 Point I O Module Model A100 1290 in the audio panel Other compatible standard or noise cancelling microphones each on a A100 1274 Module needs to be the same type details Individual remote microphone wiring and PTT push to talk switch is monitored by the A100 1274 module An on board IDNet Supervised IAM monitors module status requires IDNet address and one unit load On board module diagnostic LEDs indicate Open Short Earth per microphone IAM LED indicates communication status with alarm control panel On board earth detection circuit UL Listed to Standard 864 Control Panels Multiplex Module Model A100 1274 1 Audio System with A100 1274 Microphone Module and 8 Remote Microphones 6 A4003 9803 Remote Microphones and 2 single Remote Annunciators with Remote Microphone Remote Microphones 4100ES Audio systems support up to five 5 remote For applications requiring more convenient access to microphone control the A100 1274 Microphone Multiplex allows up to eight 8 remote microphones to connect to each remote microphone input to 40 Remote Microphones two A100 1240 Auxiliary Audio Input Modules connected and five A100 1274 Microphone Multiplex Modules a total of 40 Remote are supported This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0553 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 4 03 2021 Multiplex Module Model A100 1274 Selection 1 Product selection Multiplex Module Microphone with on off switch and ready to talk LED control wiring connects to a A100 1290 24 Point I O module in audio control panel 2 Installation Instruction Reference Microphone Mux Module Installation Instructions Remote Microphone Assembly Installation Instructions 3 Additional Product Reference Basic Panel Modules and Accessories Emergency Voice Alarm Communications Equipment Remote Annunciator Panels Sheet 4 A100 1274 Microphone Multiplex Module Specifications Module size Mounting Location Remote Microphone Input Sources Audio Input Module Details Voltage Current Wiring Information field wiring microphones active microphone active microphone active and keyed keyed microphones Supervised IAM between Microphone Module and Remote Input Microphone Wiring Microphone Distance Supervised IAM Details and Wiring Information requires wiring 4 x 5 block module either in same cabinet or close nippled to the cabinet housing the Audio or Auxiliary Audio Input Module Audio Controller Models A100 1311 Audio Controller Model A100 1210 Audio Input Module Model A100 1240 to remote microphone outputs 3 and 4 to two A100 1240 Auxiliary Audio Input Modules can be connected to a Audio Controller Module VDC system power mA mA mA 39 mA for each keyed microphone supplied by IDNet Signaling Line Circuit SLC twisted shielded pair TSP wiring to Audio Controller or Auxiliary Audio Input AWG 0.82 mm2 TSP ft maximum 1220 m one IDNet address and one IDNet unit load address is switch selected to the control panel IDNet communications source desired wire using 18 twisted pair Temperature Humidity Range 5 A4003 9803 Remote Microphone VDC system power from A100 1290 24 Point I O Module mA maximum in use AWG 0.82 mm2 twisted shielded pair TSP for microphone 5 control wires keyswitch PTT switch and LED control 6 General Environmental Specifications to 120 F 0 to 49 C to 93 RH non condensing 90 F 32 C 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 4 03 2021 Remote Microphone Reference Multiplex Module Model A100 1274 3 Rev 4 03 2021 Multiplex Module Model A100 1274 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 4 03 2021

Related Files