Autocall Model A190-9027, 24-Pin Dot Matrix Fire Alarm System Remote Printer
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-model-a190-9027-24-pin-dot-matrix-fire-alarm-system-remote-printer-5890423176.pdf |
---|---|
Type | |
Size | 876.34 KB |
Downloads |
Text Preview
UL ULC CSFM Listed Alarm System Accessories A190 9027 24 Pin Dot Matrix Fire Alarm System Remote Printer resolution 24 pin dot matrix bi directional printer for use Autocall model 4190 TrueSite Workstation TSW 4190 PC Annunciator Fire Alarm Control Panels 4100ES 4010ES 4007ES Other legacy Autocall fire alarm control units with serial printer Contact your local Autocall product representative for hard copy records of System events with alarm conditions automatically printed bold Alarm Historical Log Trouble Historical Log TrueAlarm Status Report TrueAlarm Service Report TrueAlert Device Report TrueNAC Status Report TrueAlarm CO Report Install Mode List Report Alarm Verification Tally Report TrueAlertES Self Test Report TrueAlertES SpeakerTap Report Advanced Earth Fault Diagnostic Report The list above is product dependent Refer to the specific product to verify which reports are supported RS 232 USB or parallel communications interface communications and AC input are transient protected is a high resolution 24 pin printer for use with Autocall fire alarm units and related systems It is listed for supplemental fire signaling system operation under UL Standard 864 suppression is included for both RS 232 communications and VAC power Testing is performed to ensure proper operation with UL listed fire alarm control equipment printer operations include recording of fire alarm system activity fire response documentation documenting non fire alarm activity as security monitoring of door openings and WALKTEST system results and documenting other related activity such as AC power and restoration as directed by the connected unit Additionally information may be printed such as TrueAlarm analog sensor and service reports for analysis of smoke detection sensitivity to Sample Event Printouts to Installation Instructions 579 1310AC for additional information 1 Fire Alarm System Printer 1 Specifications voltage power current print current speed width size high speed sheet VAC to 240 VAC 50 Hz to 60 Hz W A typical A cps 10 cpi cps 10 cpi cps 12 cpi cps 10 cpi cps 12 cpi cps 15 cpi cps 10 cpi cps 12 cpi columns 10 cpi kB 9 10 in to 10 1 10 in mm to 257 mm and up to 5 copies carbonless 9 10 in H x 17 1 5 in W x 12 3 5 in D mm x 437 mm x 320 mm lbs 7.2 kg to 95 5 to 35 to 80 RH non condensing S015337 Supervised Unsupervised temperature ribbon Device Type note that the printer specifications supplied under this model may vary slightly due to product availability This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7300 0026 0320 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 1 1 2020 Event Printouts A190 9027 24 Pin Dot Matrix Fire Alarm System Remote Printer TrueAlarm Status Service Reports 2 event printout 3 Status and Service Report 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 1 1 2020