Autocall Multi-Candela, High Intensity (non-addressable) Strobe and Horn Strobe
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-multi-candela-high-intensity-non-addressable-strobe-and-horn-strobe-7543910286.pdf |
---|---|
Type | |
Size | 2.52 MB |
Downloads |
Text Preview
Datasheet Multi Candela Notification Appliances High Intensity non addressable Strobe and Horn Strobe Mount appliances install using standard single gang electrical boxes appliances install using standard 4 electrical boxes Color is determined by model number 1 Intensity Strobes and Horn Strobes Intensity Selection installation a selection plug at the back of the housing the desired strobe intensity An attached flag with black on a highly visible yellow background allows the selected intensity be seen at the side of the strobe lens Application Selection selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA Two Wire Control operation mode allows a two wire circuit to provide the ability activate both the horn and strobe on the same NAC and then allow horn to be silenced while the strobe remains flashing The horn as on until silenced while the strobe operation is on until Control Sources two wire control is available from Hybrid 4010ES 4100ES Fire Alarm Control Panels refer to product data sheets for more information IDNet NAC Extenders refer to data sheet AC4009 0002 Control Module SCM Model A4905 9938 refer to data sheet ULC CSFM Listed FM VDC high intensity notification appliance common features Xenon strobe with intensity selectable as 135 177 or 185 candela selection jumper is secured behind strobe housing Regulated circuit design ensures consistent flash output and provides inrush current Control is compatible with Autocall SmartSync two wire operation Operation is compatible with ADA requirements Rugged high impact flame retardant thermoplastic housings available red or white with clear lens Models are available for wall or ceiling mount Strobe operation is UL listed to Standard 1971 with audible notification horn Low current electronic horn with harmonically rich sound output for either steady or coded operation Temporal or 60 BPM Time pattern Horn operation is UL listed to Standard 464 provide synchronized flash for use with Autocall fire alarm control panels and NAC Extenders when selected to strobe synchronization or SmartSync two wire control Separate strobe Synchronization Modules or SmartSync Control SCMs that convert conventional NAC inputs to a Smartsync two wire operation provides Horns controlled separately from strobes on the same two wire circuit as Temporal pattern March Time pattern at 60 BPM or on mount appliance features Wiring terminals are accessible from the front of the housing providing access for installation inspection and testing Covers are available separately to convert housing color A V models have an available UL listed sound damper for locations attenuation of 5 to 6 dBA stairwells small rooms highly areas etc adapters and wire guards Wall mount A V adapters are available to cover surface mounted boxes and to adapt to 2975 9145 boxes UL listed red wire guards are available for wall or ceiling mount A Vs Selection and Installation multi candela high intensity appliances provide convenient to standard electrical boxes They are both impact and resistant and provide a convenient strobe intensity selection each model can be selected for strobe intensity output on model inventory is minimized and changes encountered during can be easily accommodated Mount are a one piece assembly including lens that mounts to a or double gang or 4 square standard electrical box The cover be quickly removed a tool is required and covers are available for color conversion This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0523 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 6 03 2021 High Intensity non addressable Strobe and Horn Strobe strobe with intensity selectable as 135 177 or 185 candela flash rate SmartSync two wire control compatible Selection White White 1 Strobe V O Product Selection Description 2 Horn Strobe A V Product Selection Description Model and multi candela strobe with intensity selectable as 135 177 or 185 synchronized flash rate operates with SmartSync two wire control 3 Wall Mount Common Accessories Mount Adapter Skirt use to cover 1 1 2 38 mm deep surface boxes Adapter Plate for mounting to 2975 9145 box typically for retrofit may be mounted or horizontal only Optional Sound Damper package of 20 field installed adhesive backed horn attenuator reduces output 5 to 6 dBA Sound Damper installation measure sound level to ensure compliance with code requirements Model Wall Mount Replacement cover with white FIRE lettering White Wall Mount Replacement cover with red FIRE lettering 4 Wire Guards and Adapters or V O Wall Mount Red Wire Guard with Mounting Plate for semi flush or surface boxes Ceiling Mount Red Wire Guard with Mounting Plate for semi flush or surface mounted H x 5 1 4 W x 1 5 8 D 136 mm 133 mm x 41 mm depth w strobe 111 mm x 5 3 4 x 0.060 Thick 211 mm 146 mm x 1.5 mm Diameter 44.5 mm with 0.31 8 sound opening H x 5 W x 1 1 2 D 130 mm x mm x 38 mm H x 6 1 16 W x 3 1 8 D 154 x 154 mm x 79 mm x 4 3 8 x 2 7 8 deep 156 mm x mm x 73 mm x 6 1 8 x 3 216 mm x 156 mm x mm Ceiling Mount Red Wire Guard for mounting to flush mounted electrical box Adapter Plate required to mount 4905 9927 guard to surface mounted electrical box 9 x 7 229 mm x 178 mm Mount Adapter Plate zinc plated required for mounting to handy box not needed using 4905 9926 guard Mount A V Surface Mount Adapter Box Extension use to cover 1 1 2 surface mounted boxes x 3 1 8 x 0.060 D 124 mm x 79 x 1.5 x 6 7 8 x 1 1 2 deep 121 mm x mm x 38 mm UL listed by Space Age Electronics Inc 2 Rev 6 03 2021 Reference Surface or Semi Flush Mounting High Intensity non addressable Strobe and Horn Strobe 3 mount height reference 2 reference surface or semi flush mounting Figure 2 shows optional A4905 9838 sound damper 3 Rev 6 03 2021 Mount High Candela Appliances Installation Reference High Intensity non addressable Strobe and Horn Strobe 4 Mount High Candela Appliances Installation Reference Figure 4 shows Optional A4905 9915 A4905 9916 Adapter for A V installation recommended for surface mounted box Optional A V 4905 9927 Red Wire Guard 4905 9910 Adapter Plate required for surface mount V O installation with handy box unless using the 4905 9926 wire guard Optional 4905 9926 wire guard with mounting plate for V O installation 4 Rev 6 03 2021 Mount Installation Reference Adapter Plate Guard and Adapter Skirt High Intensity non addressable Strobe and Horn Strobe 5 Mount Installation Reference Adapter Plate Guard and Adapter Skirt Figure 5 shows A4905 9931 Adapter Plate 4905 9961 Optional Wire Guard 2975 9145 back box Optional Surface Mount Adapter Skirt 1 1 2 deep A4905 9937 Red A4905 9940 White conduit knockouts are provided on all four sides shown for reference A V mounts the same 5 Rev 6 03 2021 to Instructions 579 859AC for a