Autocall Multi-Candela Visible Only (V O) Amber Lens Ceiling Mount Strobes for Emergency Communications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-multi-candela-visible-only-v-o-amber-lens-ceiling-mount-strobes-for-emergency-communications-4105728963.pdf |
---|---|
Type | |
Size | 886.15 KB |
Downloads |
Text Preview
UL ULC CSFM Listed Addressable Notification Appliances Visible Only V O Amber Lens Ceiling Mount Strobes for Emergency installation to standard electrical boxes TrueAlert addressable amber lens strobes provide installation to standard electrical boxes The strobe individually addressed and individually controlled with power and control supplied from a Autocall fire alarm control panel IDNAC Signaling Line Circuits SLCs amber lens multi candela strobes provide non fire alarm alert for use with Emergency Communications systems where response information is provided by audio or textual Application Reference strobes used as part of an Emergency Communications system located to provide the same area coverage as required of clear lens alarm strobes Specific Emergency Communications requirements discussed in detail in document UFC 4 021 01 USA Department of United Facilities Criteria and in NFPA 72 Chapter 24 2010 and editions strobe coverage criteria is further described in the National Fire Code NFPA 72 ANSI A117.1 the appropriate model building BOCA ICBO or SBCCI and the application guidelines of the with Disabilities Act ADA SLC Operation Advantage notification using a single two wire circuit V O Appliances with Addressable Amber Strobes on IDNAC provide visible notification using a single two wire circuit that also connection to the individual notification appliance electronic This operation increases circuit supervision integrity by providing that extends beyond the appliance wiring connections current current allows efficient IDNAC SLC operation With IDNAC a constant 29 VRMS source voltage is maintained even during standby allowing strobes to operate at higher voltage with current and ensuring a consistent current draw and voltage drop under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions installation and testing time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When Class B wiring is used wiring can be T tapped allowing savings in distance wire conduit size and utilization and installation efficiency Use of the magnet test feature improves efficiency TrueAlert device reports conveniently identify about each connected appliance 1 Mount Addressable Amber Lens V Os addressed and controlled multi candela V O visible notification appliances provide Amber lens with ALERT lettering produces a signal unique from lens fire alarm evacuation strobes for use with Emergency Systems Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected as 30 75 or 110 cd Advanced addressable notification controlled by IDNAC SLCs from 4100ES fire alarm control panels with EPS EPS power and 4009 IDNAC Repeaters providing regulated 29 VRMS strobes to operate with lower current even under battery Separate device type allows connection on same SLC as clear lens with independent operation clear strobes for Fire Alarm strobes for Alert Operation is clear Fire OR amber Alert not Wiring supervision to each strobe allowing T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring TrueAlert Device Reports at the control panel detailing appliance point custom label type and candela setting Magnet test diagnostics to assist checkout and testing of appliances wiring Compatibility with ADA requirements UL listed to Standard 1638 due to non white lens verified by UL to provide light dispersion patterns of UL Standard 1971 at candela no derating necessary for amber lens ULC listed to Standard S526 indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate supervision In diagnostic mode the magnet test pulses the LED to indicate address AND pulses to indicate the intensity selection a brief of the strobe is also selectable to confirm operation design features Rugged high impact flame retardant thermoplastic white housing Rear of housing does not extend into box and easily mounts to electrical boxes Options include box adapters and red wire guards This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0556 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 8 1 2020 Visible Only V O Amber Lens Ceiling Mount Strobes for Emergency Communications Addressable Diagnostics Features can be selected to pulse each appliance LED when it receives a supervision poll When the controller is selected for diagnostic mode the magnet test feature provides a response at the individual appliance being tested Appliance Magnet Test this test mode in response to the magnet test the appliance LED pulses sequentially to conveniently indicate the appliance address Appliance Testing this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash to indicate proper operation Instrument Two TSIT 2nd generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert and TrueAlert ES appliances to its ability test IDCs NACs and IDNet communications before connection to the control panel Please contact your local Autocall representative for additional Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning Refer to data sheet AC4905 0001 for additional information Selection Addressable Ceiling Mount Strobe white with red ALERT lettering with lens intensity selectable as 15 30 75 or 110 candela x 2 5 16 x 2 D 121 mm x 75 mm 67 mm 1 Multi Candela Addressable Strobe with Amber Lens Mount Adapter Plate zinc plated required for ceiling surface mount boxes x 3 124 mm x 79 mm 2 V O Adapter and Wire Guard Mount V O and Guard Installation Reference Figure 2 shows the 4905 9910 Adapter plate used for surface mounting with the handy box 2 Mount V O and Guard Installation Reference 2 Rev 8 1 2020 Visible Only V O Amber Lens Ceiling Mount Strobes for Emergency Communications Amber Strobe and IDNAC SLC Controller Compatibility Reference 3 TrueAlert Amber Strobe and IDNAC SLC Controller Compatibility Reference Sheet Output SLC Output SLC VRMS regulated Voltage Reference VRMS 6 VRMS drop Controller with EPS or EPS Power Supply IDNAC Repeater Instructions to 122 F 0 to 50 C 10 to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for in out wiring 4 Common Specifications 5 Strobe Specifications Operating Voltage Range Rate and Synchronized SLC Loading VRMS Current Ratings for to IDNAC Addressable Setting VRMS to 31 VRMS Special Application see below for 17 VRMS rating Hz with up to 46 synchronized strobes maximum per NAC maximum 30 resistance appliances cd mA cd mA cd mA cd mA Strobe LEGACY Compatibility Reference 6 TrueAlert Strobe LEGACY Compatibility Reference Controller with TrueAlert Power Supply TPS Remote TrueAlert Power Supply Addressable Controller 4009T Sheet Output Strobe Voltage Addressable