Autocall Multi-Candela Visible Only (V O) Appliances (Strobes), Ceiling Mount
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-multi-candela-visible-only-v-o-appliances-strobes-ceiling-mount-3590246187.pdf |
---|---|
Type | |
Size | 1.04 MB |
Downloads |
Text Preview
Datasheet Addressable Notification Appliances Visible Only V O Appliances Strobes Ceiling Mount ULC CSFM Listed FM addressed and controlled multi candela V O visible notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected as 30 75 or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing 29 VDC allowing strobes to operate with lower current even battery backup Wiring supervision to each strobe allowing T tapped connections for B circuits to simplify wiring Class A circuits require in out wiring TrueAlert Device Reports at the control panel detailing appliance point custom label type and candela setting Magnet test diagnostics to assist checkout and testing of appliances wiring replacement Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade UL listed to Standard 1971 and ULC S526 indicator and magnet test feature Appliance LED can be selected to display each polling cycle to indicate supervision In diagnostic mode the magnet test pulses the LED to indicate address AND pulses to indicate the intensity selection a brief of the strobe is also selectable to confirm operation design features Rugged high impact flame retardant ceiling mount thermoplastic are available in red or white Rear of housing does not extend into box and easily mounts to electrical boxes electrical boxes Mounting options include red wire guards and adapters for surface TrueAlert addressable strobes TrueAlert addressable strobes provide convenient to standard electrical boxes The strobe is individually and individually controlled with power supervision and supplied from a Autocall fire alarm control panel providing Signaling Line Circuits SLCs Application Reference selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm Signaling Code NFPA 72 ANSI A117.1 the appropriate model code BOCA ICBO or SBCCI and the application guidelines of Americans with Disabilities Act ADA SLC Operation Advantage addressable appliances on IDNAC SLCs provide separate and audible notification using a single two wire circuit that also connection to the individual notification appliance electronic This operation increases circuit supervision integrity by providing that extends beyond the appliance wiring connections 1 Mount Addressable V Os current allows efficient IDNAC SLC operation With SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby include wiring distances up to 2 to 3 times farther than with notification or support for more appliances per IDNAC SLC use of smaller gauge wiring or combinations of these benefits all installation and maintenance savings with high assurance that that operate during normal system testing will operate during case alarm conditions Installation and Testing Time With separate controls on same two wire SLC installation time and expense for both retrofit new construction can be significantly reduced When Class B wiring used wiring can be T tapped allowing more savings in distance conduit size and utilization and overall installation efficiency Use the magnet test feature improves installation efficiency TrueAlert reports conveniently identify information about each connected Addressable Wiring Isolator Model A4905 9929 is available for remote mounting on addressable circuits to isolate short circuited wiring from wiring Refer to data sheet AC4905 0001 for additional Addressable Diagnostics Features Controllers can be selected to pulse each appliance when it receives a supervision poll When the controller is selected diagnostic mode the appliance magnet test feature provides a at the individual appliance being tested Appliance Magnet Test In this test mode in response to the test the appliance LED pulses sequentially to conveniently the appliance address Appliance Testing In this test mode after the address indicated by pulsing the appliance LED the strobe will briefly flash to proper operation Instrument Two TSIT The 2nd generation of the TrueStart Test Instrument adds testing of IDNAC SLC wiring TrueAlert and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control Please contact your local Autocall representative for additional This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0527 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 6 03 2021 Visible Only V O Appliances Strobes Ceiling Mount Selection Color Lettering x 2 5 x 2 D 121 mm x 75 mm x mm Addressable Strobe intensity as 15 30 75 or 110 candela 1 Multi Candela Ceiling Mount Addressable Strobe Mount Surface Mount Adapter Plate zinc plated required for ceiling surface x 3 124 mm x 79 mm 2 V O Adapters Mount V O and Guard Installation Reference SLC Controller Compatibility Reference Controllers with EPS or EPS Power Supply IDNAC Repeater with IDNAC Notification with ESS Enhanced System Supply 3 Compatibility Reference Sheet Output SLC Output Voltage Reference SLC VDC regulated VDC 6 VDC drop 2 Rev 6 03 2021 Visible Only V O Appliances Strobes Ceiling Mount Instructions Operating Voltage Range Requirements Rate and Synchronized SLC Loading Setting VDC RMS Current Ratings for connection to Addressable SLCs 4 General Specifications to 122 F 0 to 50 C 10 to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for wiring 5 Strobe Specifications VDC to 31 VDC Special Application see below for 17 VDC rating unit load 0.8 mA control panel current Hz with up to 46 synchronized strobes maximum per NAC cd cd cd mA mA mA cd mA Strobe LEGACY Compatibility Reference 6 TrueAlert Strobe LEGACY Compatibility Reference Controller with TrueAlert Power Supply TPS Remote TrueAlert Power Supply Addressable Controller 4009T Sheet Output Addressable Strobe Voltage 30 75 and 110 cd 17 VDC 7 Electrical Ratings Difference for Retrofit Applications Range Setting VDC RMS Current Ratings use when connected TrueAlert Addressable SLCs per above VDC to 31 VDC Special Application cd mA cd mA cd mA cd mA 3 Rev 6 03 2021 Visible Only V O Appliances Strobes Ceiling Mount 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 6 03 2021