Autocall Network System Integrator NSI

File Preview
File Preview
Click below to download for free

File Data

Name autocall-network-system-integrator-nsi-0359274816.pdf
Type PDF
Size 3.77 MB
Downloads

Text Preview

UL ULC and CSFM Approved Approved with Autocall ES Net Network flexible integration of fire alarm control panels into the ES Net Network Network Communication between the ES Net Network fire alarm network and fire alarm control panels is via dry contact closure connections Typical compatible controls include Autocall fire alarm control panel series non Autocall fire alarm control panels or other building controls including products for Emergency Communication ECS MNS intrusion alarm etc Standard equipment provides 8 I O points each programmable as an or relay output Includes 6 Amp power supply for auxiliary power with integral battery for secondary power requirements Optional modules support expansion for up to 32 individually I O points Includes ES Net Network Interface Card suitable for Class B or Class X media modules ordered separately 109 mm Diagonal color touchscreen display Convenient and intuitive user interface provides for NSI status testing diagnostics and historical log access Supports dual language selection including unicode character A custom background display appears when operation is normal Feature Summary Current and previous NSI configuration are both maintained in on memory to allow easy selection of desired revision An internal Ethernet service port is available for service computer to perform configuration updates downloads and report downloads and system software updates Internal USB interface allows a memory stick thumb drive to store job update revised jobs and panel software and save detailed reports from the NSI modules and connections include ES Net Network media modules for Ethernet single mode or multi fiber optic or DSL connections Eight Point Zone Relay Modules individually selectable as IDC or relay 2 A 30 VDC resistive Mechanical Compact red or platinum cabinet for convenient surface or semi flush rated NEMA 1 and IP30 Listings reference UL 864 Control Unit Accessories System Fire Alarm UOXX ULC S527 Control Unit Accessories System Fire Alarm UOXX7 UL 2017 Emergency Alarm System Accessories FSYE Alarm Network Products System Integrator NSI System Integrator Network System Integrator provides a gateway between any building panel into the Autocall ES Net fire alarm network This allows from other building control panels that are not equipped for network communications to be annunciated on the Autocall fire network NSI uses zones to monitor dry contact closures on the building panel and makes those zones public on the Autocall network notifying other nodes on the Autocall network of any status Dry contact relay outputs from the NSI can also be used to status conditions from the NSI or other network nodes to the building control panel Interface Status Information The user interface is a 4.3 diagonal touchscreen LCD with separate status LEDs as shown below indicators describe the general category of activity being displayed the LCD providing more detail For the authorized user unlocking door provides access to the control functions and allows further by scrolling the display for additional detail listings may be applicable contact your local Autocall product supplier for the latest status Rev 3 03 2021 System Integrator NSI Description Locking door Latching front panel assembly swings forward for convenient internal access Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Modules are power limited except as noted such as relay modules Battery compartment bottom accepts two batteries up to 18 Ah to be mounted within the cabinet without interfering with module space charger is up to 33 Ah for batteries greater than 18 Ah refer to Table 5 for external battery cabinet details Supply Output and Zone Relay Module Details Supply Output Details 6 A Output Rating This includes current for module currents and auxiliary output current battery charging CPU and power supply current are subtracted from the 6 A Low Battery Voltage Cutout is selectable when required required for ULC listing applications Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions status information provided to the controller includes analog values for battery voltage charger voltage and current and actual system voltage and current Battery Charger is dual rate temperature compensated and charges up to 18 Ah sealed lead acid batteries in the battery compartment and up to 33 Ah batteries in an external cabinet Display with LED Status Indicators approximately full size 2 Rev 3 03 2021 Screen Reference Menu Screen provides easy navigation to the function required A B and C have programmable functions Alarm Screen identifies active alarms with custom labels arrows allow navigation through the list System Integrator NSI Trouble Screen identifies active troubles with custom labels arrows allow navigation through the list Log Screen allows review of past troubles with time stamp and details shown Information Screen allows review of point details arrows allow through the information Access Login Screen controls access to panel operations as per panel Interface and Software Features A logical menu driven touchscreen display with password access control that accesses convenient and detailed operator information Multiple automatic and manual diagnostics for maintenance reduction View Alarm and Trouble History Logs up to 1000 entries for each 2000 total events on the display Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring 3 Rev 3 03 2021 Mounting and Module Location Reference System Integrator NSI 1 mounting and location reference Locations CPU and User Interface assembly Power Supply Assembly Location for additional A007 9801 Zone Relay Module Primary location for A007 9801 Zone Relay Module included Location for additional A007 9801 Zone Relay Module Location for additional A007 9801 Zone Relay Module Block 7 is an additional block that sits on spacers above Block 5 and 6 The A007 9817 NIC can be mounted in block 7 with or without modules below it in blocks 5 and 6 Battery location for up to 18 Ah batteries Note No conduit entry or wiring in this area 14 7 8 378 mm wide A system ground must be provided for Earth Detection and transient protection devices This connection shall be made to an approved Earth connection per NFPA 70 Article 250 and NFPA 780 4 Rev 3 03 2021 System Integrator NSI Selection models above include 1 Product Selection NSI for ES Net Network A007 9801 Zone Relay Card A007 9817 ES Net Network Interface Card mA mA mA mA mA mA The base NSI current without included modules does not subtract from the 6 A of power available for optional modules and external loads For supply loading calculations include all NSI modules plus all external loads and exclude the NSI current For battery standby calculations include NSI modules all external loads and the base NSI current and Accessories Selection Information 2 Field Installed Optional Modules Point Zone Relay Module each point is selectable as an IDC input or Relay output Class A IDCs require points one out and one return select up to 4 maximum current shown is for 8 Class B IDCs with 4 in detector current is added separately refer to 4007ES Hybrid data sheet AC4007 0001 for additional mA max 351 mA 3 Media Modules for NSI with ES Net Network Interface Card Net Ethernet Media Card Net DSL Media Card Net SM Fiber Media Card Net MM Fiber Media Card media cards as required mounts on the supplied ES Net network interface card supports Class B or X operation per network connection requirements mounts on the ESNet NIC up to 2 media cards per slot type and flat type fiber media service kits for retrofit jobs where ST connectors already installed refer to data sheet AC4100 0076 for full

Related Files