Autocall Non-Addressable Visible Only Amber Lens Strobes for Emergency Communications

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Multi Candela Notification Appliances Visible Only V O Amber Lens Strobes for Emergency Communications only V O 24 VDC wall mount notification appliances with output xenon strobe Amber lens with ALERT lettering produces a signal unique from lens fire alarm evacuation strobes for use with Emergency Systems Intensity is selectable as 15 30 75 or 110 candela with visible jumper secured behind strobe housing UL listed to Standard 1638 due to non white lens verified by UL to provide light dispersion patterns of UL Standard 1971 at candela no derating necessary for amber lens ULC listed to Standard S526 Polarized input allows connection to compatible reverse polarity notification appliance circuit NAC Regulated circuit design ensures consistent flash output and provides inrush current Rugged high impact flame retardant thermoplastic housings are in red or white with amber lens provide synchronized flash for use with 4100ES Series fire alarm control panels with NACs selected to provide synchronization or SmartSync two wire horn strobe control 4009 IDNet NAC Extenders Separate strobe synchronization modules that are available for Class B Class A operation Separate SmartSync Control Modules SCMs that provide Class B or A output from conventional NAC inputs Connect amber strobes to NACs dedicated for Emergency Com operation not for fire alarm notification housings provides flexible easy and convenient semi or surface mounting Rear of housing does not extend into box Strobes easily mount to single gang double gang or 4 inch square box Wiring terminals are accessible from the front of the housing providing access for installation inspection and testing adapters and wire guard Strobe adapters are available to cover surface mounted electrical and to adapt to 2975 9145 boxes UL listed red wire guard 1 Lens Wall Mount Strobes amber lens multi candela strobes non fire alarm alert notification for use with Emergency systems where additional response information is by audio or textual appliances housings a one piece assembly including lens that mounts to a single or gang or 4 square standard electrical box The cover can be removed a tool is required and the enclosure design is impact vandal resistant Output installation a selection plug at the back of the housing the desired strobe intensity An attached flag with black on a highly visible yellow background allows the selected intensity be seen at the side of the strobe lens Application Reference strobes used as part of an Emergency Communications system located to provide the same area coverage as required of clear lens alarm strobes Specific Emergency Communications requirements discussed in detail in document UFC 4 021 01 USA Department of United Facilities Criteria and in NFPA 72 Chapter 24 2010 and editions strobe coverage criteria is further described in the National Alarm and Signaling Code NFPA 72 ANSI A117.1 the appropriate building code BOCA ICBO or SBCCI and the application of the Americans with Disabilities Act ADA This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0504 7125 2269 0527 7125 2269 0525 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest Rev 5 1 2020 Visible Only V O Amber Lens Strobes for Emergency Communications Strobes Strobes multiple strobes and their reflections can be seen from one location synchronized flashes reduce the probability of photo sensitive reactions well as the annoyance and possible distraction of random flashing These multi candela strobes are synchronized over a two wire circuit when to compatible NACs to compatible Synchronized Flash Modules or to SmartSync Control Modules Two Wire Control Reference Alarm Operation two wire control provides separate horn and strobe control over the same wiring This allows audible notification appliances to be capable being silenced before the alarm condition is reset on until silenced while the visible notification appliances are kept activated until the alarm is reset on until reset Operation non addressable amber strobes are used to provide alert indications audible information is provided by a voice audio system or other unique alarm signaling Refer to the Additional Product Reference list to the right for associated products applications requiring multiple NAC synchronization may require amber strobe control from synchronized A4905 9938 SmartSync Control Product Reference 1 Multi Candela Clear Lens Strobes strobe horn strobe speaker strobe 2 Audible Notification 3 Control Modules and Panels and SmartSync Control Modules IDNet NAC Extender Fire Alarm Control Panels Fire Alarm Panels Fire Alarm Audio Equipment Series Emergency Voice Alarm Communications Equipment Panel compatible with 4010 control 4 Installation Reference Instructions Sheet Sheet Sheet Sheet 2 Rev 5 1 2020 Visible Only V O Amber Lens Strobes for Emergency Communications Selection Color Lettering strobe with amber lens intensity selectable as 15 30 75 or 110 candela flash rate SmartSync two wire control compatible 5 Multi Candela Visible Notification Appliances Strobes 6 Mounting Adapters White Mount Adapter Skirt use to cover 1 1 2 38 mm deep surface boxes Adapter Plate for mounting to 2975 9145 box typically for retrofit may be vertical or horizontal Mounting Box requires Adapter Plate A4905 9931 H x 5 1 4 W x 1 5 8 D 136 mm x mm x 41 mm Total depth with strobe 111 mm x 5 3 4 x 0.060 Thick 211 mm x 146 x 1.5 mm x 5 1 8 x 2 3 4 D 200 mm x 130 mm x mm 7 Synchronization Modules refer to data sheet AC4905 0003 for additional information B A Control Module with Class B or Class A output mounts in 4 102 mm square Flash Module epoxy encapsulated with in out AWG 0.82 mm2 wire leads rated for 2 A NAC requires mA for power x 2 7 16 x 13 16 35 x 62 mm x 20 mm x 4 1 8 x 1 1 4 D 102 mm 105 mm x 32 mm 8 Wire Guard wire guard with mounting plate compatible with semi flush or surface mounted boxes UL listed by Space Age Electronics Inc H x 6 1 16 W x 3 1 8 154 mm x 154 mm x 79 3 Rev 5 1 2020 Visible Only V O Amber Lens Strobes for Emergency Communications Specifications Range Rate NAC Loading Range Range Dimensions with lens RMS Current Rating per Strobe Setting see 2 below RMS Currents at other voltages VDC VDC 9 Strobe Specifications 24 VDC see Note 1 below Hz to 35 synchronized strobes maximum per NAC to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for in wiring H x 5 W x 2 3 4 D 130 mm x 127 mm x 70 mm cd mA mA mA cd mA mA mA cd mA mA mA cd mA mA mA 24 VDC refers to the voltage range of 16 to 33 VDC per UL Standard 1638 Visual Signaling Appliances Private Mode Emergency and Utility Signaling This voltage range is the absolute operating range Operation outside of this range may cause permanent damage to the Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions The maximum RMS current listed is the device nameplate rating Strobe designs are constant wattage and the maximum RMS current rating at the lowest allo

Related Files