Autocall Panel Mounted Digital Alarm Communicating Transmitters with Serial Communications (SDACT)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-panel-mounted-digital-alarm-communicating-transmitters-with-serial-communications-sdact-3214095786.pdf |
---|---|
Type | |
Size | 1.05 MB |
Downloads |
Text Preview
Datasheet Accessories Mounted Digital Alarm Communicating Transmitters with Serial Communications ULC CSFM Listed FM 864 listed per NFPA 72 National Fire Alarm and Signaling for Central Station Service Operation is listed to UL Standard 1459 Telephone Equipment Registered to FCC Part 68 telephone line interface Requires Data Certified POTS lines Also compatible with DACT to Ethernet connection interfaces refer to DACR Compatibility Reference internally to Autocall models 4007ES 4010ES and 4100ES For Network applications select a 4100ES node for Network SDACT reporting when available specific building event information Communicates point status changes phone line status and other off information Reports up to ten events per phone call programmable control for Automatic 6 hour test Power fail report delay status indicators include Panel LCD indicates off normal status Module LEDs provide service diagnostics DACT serial digital alarm communicating transmitter SDACT monitor the status of the host fire alarm control panel and its to the Central Station monitoring location When status require information to be reported the SDACT provides messages that can assist the Central Station in accurately the required response Typical information reports include troubles and supervisory conditions Model series 4007ES and 4100ES provide specific point information modules directly communicates with the fire alarm control panel and are custom programmed for the specific requirements of the Station and the connected fire alarm control panel 1 Application Diagram Reporting Formats ID CID CID is the preferred format for SDACT operation It a four digit account code followed by a three digit event code a hex digit group number and a three hex digit contact number all which are used to encode specific point identification Pulse A three digit account code followed by a one digit reporting Transmissions are sent as a double round at a rate of 20 PPS per second Reporting codes are programmable Pulse Similar to 3 1 except for a four digit account code and a two reporting code Transmission is sent as a double round at 20 PPS codes are programmable Three digits of account code and two digits of reporting code in single transmission of constant tones The format has built in error so that a double round is not required Reporting codes are Security Industry Association SIA Digital Communication The SDACT provides level 1 compatibility which includes tonal basic reports only and fixed reporting codes This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7165 2269 0542 7165 2269 0541 7165 2269 0536 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest Rev 9 03 2021 Mounted Digital Alarm Communicating Transmitters with Serial Communications SDACT Product Selection and Reference Alarm Control with EPS 1 SDACT Product Selection and Reference Location 2 in slot module side of CPU bay end support or left of an expansion bay D right corner of cabinet mounted with included 650 1838 mounting Data Sheet Alarm with Serial SDACT Capacity SDACT Capacity Temperature Humidity Registration Type 2 General Specifications VDC from panel 30 mA Report Mode 40 mA points maximum received is determined by capability of the digital alarm communicating receiver DACR and format used to 2 A100 6052 SDACTs can be selected to 120 0 to 49 RH 85 30 3 Telephone Requirements 2 required start pulse or tone dialing Data Certified POTS lines 2 Rev 9 03 2021 Mounted Digital Alarm Communicating Transmitters with Serial Communications SDACT DACR Compatibility Reference 4 Compatibility Reference Communication Format CID Standard Hz and 20 Standard Hz and 20 Standard Hz and 20 Standard Hz and 20 Hz Hz Model II 685 with Line Card Knight 9000 9004 line 9004 line 9004 line 9004 line 9004 line 9004 line 9004 line CP220FB with Line Card Radionics Radionics MLR2 DG Yes TL300 UL listed C900V2 UL With or without D6680 Network Ethernet Adapter in D6600 DACT to Ethernet connection interfaces 3 Rev 9 03 2021 Mounted Digital Alarm Communicating Transmitters with Serial Communications SDACT 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 9 03 2021