Autocall SmartSync 2-Wire Operation, Non-Addressable Electronic Chime

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Notification Appliances 2 Wire Operation Non Addressable Electronic Chime rate current 24 VDC Autocall SmartSync operation electronic provide Private mode chime tone for applications requiring audible notification trained personnel Rugged high impact flame retardant thermoplastic housings available red with white FIRE lettering or white with red FIRE lettering Diode polarized input for connection to reverse polarity supervised control Notification Appliance Circuits NACs two wire control of audible and visible notification provides SmartSync control of chime tone as Temporal Pattern March Time at 60 BPM or on continuously at 60 BPM controlled from visible appliances on the same circuit Visible appliances on the same circuit operate at a synchronized 1 Hz Refer to page 2 for SmartSync control list and additional operation notification appliance design provides flexible easy convenient semi flush or surface wall mounting Easily mounts to single gang double gang or 4 inch square electrical In out wiring terminals 18 AWG to 12 AWG Rear of housing does not extend into box Accessories Mounting adapters to cover surface mounted electrical boxes and to to 2975 9145 boxes Covers are available separately to change color or for replacement Listed to UL 464 for private mode applications mode audible notification appliances non addressable chimes are private mode audible notification for applications requiring notification of trained personnel of the general public Typical applications would be in medical areas where the softer chime tones are less disruptive than fire alarm audible notification two wire advantage selected for SmartSync mode chimes follow control signals on the same two wire NAC circuit as fire alarm strobes Using a control can significantly reduce installation time and expense both retrofit and new construction operation mode allows both the chime and strobe to be on the same NAC and then allow the chime to be silenced the strobe remains flashing The chime operates as on until while the strobe operation is on until reset mounting can be semi flush or surface mounted on a standard single double gang or 4 square 102 mm electrical box Optional are available to increase mounting and application flexibility 1 Chimes are Available as White Red Lettering or Red with White Lettering Two Wire Control operation mode allows a two wire circuit to provide the ability activate both the chime and strobe on the same NAC and then allow chime to be silenced while the strobe remains flashing The chime as while the strobe operation is Control Sources two wire control is available from IDNet NAC Extenders refer to data sheet AC4009 0002 Control Module SCM Model A4905 9938 refer to data sheet This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0527 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 2 1 2020 2 Wire Operation Non Addressable Electronic Chime Selection 1 Product Selection Lettering Description non addressable electronic chime H x 5 W x 1 1 2 D 130 mm x 127 x 38 mm 2 Adapters to cover 1 1 2 deep surface boxes H x 5 1 4 W x 1 5 8 D 136 mm x 133 mm 41 mm Total depth with chime 3 1 8 79 mm mount red adapter skirt mount white adapter skirt Plate red for mounting to box typically for retrofit may be vertical or horizontal mounting box requires Adapter Plate x 5 3 4 x 0.060 thick 211 mm x 146 mm x 1.5 mm x 5 1 8 x 2 3 4 D 200 mm x 130 mm x 70 mm 3 Synchronization Control Module Control Module Class A or Class B installs in 4 square x 4 1 8 x 1 1 4 D 102 mm x 105 mm x 32 mm 4 Covers and Guard chime cover with white FIRE lettering chime cover with red FIRE lettering H x 5 W x 1 1 2 130 mm x 127 mm x mm Non Addressable Chime Specifications Voltage Range Current Sound Output Characteristics Output Ratings per UL 464 Reverberant test 10 ft 3 m Range Range dBA 5 TrueAlert Non Addressable Chime Specifications VDC to 33 VDC mA is adjustable from 750 Hz to 1300 Hz factory setting is approximately 800 Hz output is adjustable from 34 dBA to 63 dBA factory setting is 63 dBA to 122 F 0 to 50 C to 93 non condensing 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for in out Factory settings are recommended for most applications Always test installed sound level against local requirements 2 Rev 2 1 2020 Reference 2 Wire Operation Non Addressable Electronic Chime 2 or Semi Flush Chime Mounting Figure 3 shows Surface mount adapter skirt A4905 9937 Red A4905 9940 White conduit knockouts on all four sides 3 View of Chime Surface Mount Adapter Skirt 3 Rev 2 1 2020 Adapter Plate Installation Information 2 Wire Operation Non Addressable Electronic Chime 4 Adapter Plate Installation Information Figure 4 shows A4905 9931 adapter plate 4905 9961 optional wire guard 2975 9145 back box 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 2 1 2020

Related Files