Datasheet Notification Appliances Adapter Module for Non Addressable Notification Appliance Circuits NACs A4905 9815 CSFM Listed FM Approved the Autocall SmartSync NAC notification appliance into separate 24 VDC audible and visible appliance Power and communications are supplied by the SmartSync operation You can connect up to two SmartSync Adapter Modules to a SmartSync Operation is compatible with SmartSync control from Autocall fire control panels and from 4009 IDNet NAC Extenders Operation modes are visible and audible appliances both on or visible only with activation determined by the connected control On board circuit limits appliance inrush current and provides self overcurrent protection Wiring to audible and visible appliances is supervised with conventional polarity operation opens or shorts are reported to the control diagnostics A visible status LED lights if a wiring fault is detected by either of the output notification appliance supervision circuits output ratings Regulated 24 DC appliance power audible output is rated for up to 30 visible output is rated for up to 180 mA Special Applications appliance ratings audible output is rated for up to mA visible output is rated for up to 250 mA mechanical features Mounts in standard 4 11 16 in 119 mm square electrical box Cover plates required are available for surface or flush mount separately Covers provide status LED viewing Screw terminals for wiring connections listed to Standard 864 Notification Requirements Standard SmartSync operation appliances activate horns or strobes in response to received from the SmartSync operation control source using two wire connection For applications where appliances other than the SmartSync appliances are required the SmartSync Adapter provides a separate audible and visible output controlled by the operation control source applications are for connection to special weather proof appliances with particular sound output characteristics bells or chimes or for connection to appliances that are required satisfy specific aesthetic requirements SmartSync operation System Advantages With the Adapter Module you can control non SmartSync appliances still benefiting from the SmartSync operation ability to provide audible and visible control using a two wire connection additional information refer to 4905 9815 SmartSync Adapter Instructions 579 391AC 1 SmartSync Adapter Module One Line Wiring Reference Wiring Details with circuit protectors When connected to remote up to 200 ft from the adapter that exit the building and may exposed to harsh electrical environments the notification appliance is compatible with Autocall circuit protectors Compatible are listed in Specifications Connect both where the wiring the building and where it connects to the appliances for shielded wire For applications where notification wiring may be exposed to electrical noise twisted shielded is recommended The adapter wiring terminal block has for connecting the shields This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7300 2269 0535 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status AC4905 0005 Rev 7 08 2021 Adapter Module for Non Addressable Notification Appliance Circuits NACs Model A4905 9815 Adapter Product Selection 1 TrueAlert Adapter Product Selection Adapter Module requires surface or flush mount cover plate Resistor Harness ref 733 894AC 10 k 1 2 W two required one each for audible and visible output Mount Cover Plate Mount Cover Plate one for each A4905 9815 painted beige Adapter Installation Reference 2 TrueAlert Adapter Installation Reference 2 AC4905 0005 Rev 7 08 2021 Adapter Module for Non Addressable Notification Appliance Circuits NACs Model A4905 9815 Voltage Current Voltage NAC Current 24 DC Appliances Application Appliances 24 DC Appliance Ratings Application Ratings Distance from SmartSync Adapter Resistor Connections Circuit Protection when wiring leaves the building for appliances mount one at each end of 2 Electrical to 33 VDC see notes 1 and 2 below maximum mA maximum adapter and appliances to 32 VDC appliance inrush current is internally limited to 550 mA Output 30 mA Output 180 mA Output 50 mA Output 250 mA for appliances listed to UL Standard 1971 or UL Standard 464 use associated synchronization modules where required conventional non addressable A4901 A4903 A4904 and A4906 Series horns and combination horn strobes and speaker strobes contact your Autocall product for compatible appliances 3 Wiring Reference ft maximum 61 m k 1 2 W two required one located at each remote appliance use A4081 9008 End of Resistor Harness ref 733 894 ordered separately terminals for 18 to 12 AWG 0.82 mm2 to 3.31 mm2 Overvoltage Protector 200 mA maximum Isolated Loop Circuit Protector 5 A maximum Isolated Loop Circuit Protector 200 mA maximum 4 Mechanical and Environmental adapter mounted in bracket see Adapter Installation Reference Plate Material Range Range 11 16 in H x 5 in W x 1 9 32 in D 119 mm x 127 mm x 33 mm metal galvanized to 120 F 0 to 49 C intended for indoor operation to 90 RH non condensing at 90 F 32 C You must connect the SmartSync adapter to a NAC that provides SmartSync two wire operation The rated voltage range listed is the absolute operating range Operation outside of this range may cause permanent damage to the SmartSync 3 AC4905 0005 Rev 7 08 2021 Adapter Module for Non Addressable Notification Appliance Circuits NACs Model A4905 9815 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 7 08 2021