Autocall SmartSync Control Module and Strobe Synchronization Modules
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-smartsync-control-module-and-strobe-synchronization-modules-0354798126.pdf |
---|---|
Type | |
Size | 967.48 KB |
Downloads |
Text Preview
TrueAlert Notification Appliances Control Module and Strobe Synchronization Modules Control Module SCM A4905 9938 SCM SmartSync Control Module converts two NAC inputs into a SmartSync two wire NAC output One can be programmed to operate as on until silenced and would designated as the horn control non coded on continuously during A second NAC would be programmed to provide on until reset and would be for the visible appliance strobe control also on continuously during alarm Power is supplied by the control NAC Horn output and Synchronized Strobes In addition to the strobe and the horn independently the SCM can be switch to operate the horns as temporal coded march time coded beats minute or on continuously Strobes are activated with 1 Hz flashes SCM Features Mode Up to eight SCMs can be interconnected to system notification Interconnected SCMs are supervised proper circuit connection The horn input NAC powers the Multi Sync NAC Inputs Both NAC inputs are isolated from each other can be supplied from different control panels B Style Y and Class A Style Z output operation are both fault detection is provided by the strobe control NAC during mode additional information refer to Installation Instructions 574 719AC Flash Modules A4905 9914 and A4905 9922 add the required control to activate synchronized strobes for NACs that do not provide that control horns or other compatible 24 VDC notification appliances the same circuit ignore strobe synchronization and operate when the is in alarm additional information refer to Installation Instructions 579 232AC ULC CSFM Listed FM 1 SmartSync Control Module 2 A Synchronized Flash Module conventional Notification Appliance Circuits NACs into circuits or synchronized strobe circuits Autocall SmartSync Control Modules combine separate horn and NAC inputs into a 2 wire control that can silence horns while synchronized strobe operation Synchronized Flash Modules provide a 2 wire synchronized strobe that also operates compatible 24 VDC conventional reverse notification appliances Control Module SCM provides two wire control to activate horns and strobes Operation allows on until silenced and on until reset on the same pair while maintaining supervision continuity SmartSync horns sound as Temporal or March Time pattern or controlled separately from strobes on the same circuit Strobes on the same circuit operate at a synchronized 1 Hz flash rate Output is either Class B or Class A strobe synchronization models Encapsulated package with color coded wire leads provides 1 Hz synchronization and maintains supervision continuity Conventional horns and other DC appliances operate on the same 2 circuit Models are available with Class B or Class A output Small size allows convenient mounting listed to Standard 1971 This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0520 7320 2269 0501 7125 2269 0523 7125 2269 0532 7300 2269 0504 7125 2269 0566 7125 2269 0524 7125 2269 0527 7125 2269 0525 7135 2269 0518 and 7135 0026 0334 for values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 5 1 2020 Control Module and Strobe Synchronization Modules Selection Control Module Class A or Class B B Synchronized Flash Module A Synchronized Flash Module plate to fit 4 11 16 119 mm square electrical box Details 4 x 4 1 8 x 1 1 4 D 102 mm x 105 mm x 32 mm mounts in 4 102 square box 1 3 8 x 2 7 16 x 13 16 D 35 mm x 62 mm x 20 mm epoxy with 8 203 mm in out 18 AWG 0.82 mm2 wire leads rated for 2 A requires 5 mA for power Range Range 1 General Specifications to 122 F 0 to 50 C to 93 non condensing at 100 F 38 C 2 A4905 9938 SmartSync NAC Modules SmartSync NAC Modules for use with SmartSync compatible appliances Voltage Range Ratings Control NAC Input Current Control NAC Current A Operation Mounting Requirement VDC to 33 VDC with a maximum ripple of 2 V peak to peak A maximum can be wired as Class A or Class B to 35 maximum SmartSync appliances with strobes to 40 maximum SmartSync horn only appliances NAC current plus 30 mA 24 VDC for SCM operating power mA 24 VDC SCM within 20 ft 6 m of control panel use metal conduit 3 A4905 9914 A4905 9922 Synchronization Modules A4905 9922 Synchronization Modules Voltage Range Ratings VDC to 33 VDC A maximum output requires 5 mA for power to 35 maximum strobes per synchronized circuit in control panel or separate 4 51 mm square electrical box 1 1 2 38 mm minimum 2 Rev 5 1 2020 Control Module and Strobe Synchronization Modules Capability Reference 4 NAC Capability Reference Panels NAC Source Hybrid 4010ES 4100ES Series Fire Control Panels and 4009 IDNet NAC Output A or Class B Strobe Synchronization A or Class B SmartSync operation Series Signal ZAMs 4009 Series NAC Extenders reverse polarity NACs additional are required to control synchronized and or SmartSync appliances Module Required Function for Class B synchronized strobes for Class A synchronized strobes for SmartSync control 5 Module Reference Control Module provides Class A or Class B SmartSync B Strobe Synchronization Module A Strobe Synchronization Module Type Autocall Appliance Reference Refer to specific appliance data sheets for additional compatibility and product information 6 Module Reference Horn w 520 Hz Tone Wall mount set for SmartSync mount set for SmartSync mount SmartSync operation mount synchronized also operation compatible Reference for SmartSync Horn Strobe Multi Tone Horn Strobe Speaker Strobe mount selectable for flash also SmartSync compatible mount SmartSync operation mount SmartSync only Hz Wall mount SmartSync only mount strobes are selectable synchronized flash mount strobes are selectable synchronized flash Modules listed are required if control panel NAC or NAC extender does not provide either synchronized strobe output or SmartSync control output required for proper appliance operation 3 Rev 5 1 2020 Installation Reference Control Module and Strobe Synchronization Modules Figure shows A4905 9938 SmartSync Control Module SCM 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 5 1 2020