Autocall SmartSync Operation Audible Visible Notification with Chime and Synchronized Flash, Non-Addressable
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-smartsync-operation-audible-visible-notification-with-chime-and-synchronized-flash-non-addressable-2604198753.pdf |
---|---|
Type | |
Size | 1.22 MB |
Downloads |
Text Preview
UL ULC CSFM Listed Multi Candela Notification Appliances Operation Audible Visible Notification with Chime and Synchronized Flash Non audible visible notification appliances have a private mode chime and a high output xenon strobe and are for wall or ceiling mount Operation is compatible with ADA requirements see Chime strobe Rugged high impact flame retardant thermoplastic housings are in red or white with clear lens notification appliances operates over a two wire Autocall circuit to provide the following features Private mode chime tones controlled separately from strobes on the two wire circuit SmartSync chime activation of Temporal pattern March Time pattern 60 BPM or on continuously at 60 BPM Strobe appliances on the same circuit operating at a synchronized 1 Hz rate See SmartSync control sources for SmartSync control list and operation information mount chime strobes features Wiring terminals accessible from the front of the housing providing access for installation inspection and testing Covers are available separately to convert housing color adapters and wire guards Wall mount adapters are available to cover surface mounted electrical and to adapt to Autocall 2975 9145 boxes UL listed red wire guards are available for wall or ceiling mount chime notification appliance strobe 24 VDC xenon strobe intensity is selectable as 15 30 75 or 110 with visible selection jumper secured behind strobe housing Regulated circuit design ensures consistent flash output and provides inrush current Listed to UL 1971 and to CSA standards for general signaling use in non fire alarm applications notification appliance chime Low current 24 VDC electronic chime with volume and tone frequency Listed to UL 464 for private mode signaling and to CSA standards for signaling use in Canada non fire alarm applications 1 and ceiling mount chime strobes TrueAlert chime strobes provide private mode notification for applications requiring notification of trained instead of the general public Typical applications would be in patient areas where the softer chime tones are less disruptive conventional fire alarm audible notification designs are both impact and vandal resistant and provide a strobe intensity selection Since each model can be selected strobe intensity output on site model inventory is minimized and encountered during construction can be easily accommodated conveniently uses standard electrical boxes mount chime strobe housings are a one piece assembly including that mounts to a single or double gang or 4 in square standard box The cover can be quickly removed a tool is required and are available separately for color conversion mount chime strobe housings install using standard 4 in boxes The model number determines color choice intensity selection installation a selection plug at the back of the housing the desired strobe intensity An attached flag with black on a highly visible yellow background allows the selected intensity be seen at the side of the strobe lens application selection selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0527 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 4 3 2021 Operation Audible Visible Notification with Chime and Synchronized Flash Non Addressable strobes strobes multiple strobes and their reflections can be seen from one location synchronized flashes reduce the probability of photo sensitive reactions well as the annoyance and possible distraction of random flashing The multi candela strobes of these chime strobes are synchronized by the SmartSync operation NAC two wire control operation mode uses a two wire circuit to provide the ability to activate both the chime and strobe on the same NAC and silence the chime the strobe remains flashing The chime operates as on until silenced while the strobe operation is on until reset control sources 4006 4007ES Hybrid 4010ES 4100ES and 4100U fire alarm control units refer to individual product data sheets for more information 4009 IDNet NAC Extender SmartSync control module SCM A4905 9938 SmartSync compatible notification appliances include separate chimes and combination chime strobe notification appliances selection 1 Multi candela chime strobes color lettering chime with multi candela strobe strobe selectable as 15 30 75 or 110 candela with SmartSync two wire control 2 Wall mount chime strobe accessories mount adapter skirt use to cover 1 1 2 or 38 mm deep surface mounted boxes adapter plate for mounting to the Autocall 2975 9145 box typically for may be mounted vertical or horizontal mounting box requires adapter plate A4905 9931 3 8 in H x 5 1 4 in W x 1 5 8 in D mm x 133 mm x 41 mm depth strobe 4 3 8 in 111 mm 5 16 in x 5 3 4 in x 0.060 in thick mm x 146 mm x 1.5 mm 7 8 in x 5 1 8 in x 2 3 4 in D 200 x 130 mm x 70 mm 3 SmartSync control module control module with Class B or Class A mounts in 4 in 102 mm square box in x 4 1 8 in x 1 1 4 in D 102 mm x 105 mm x mm 4 Replacement covers for wall mount chime strobes cover with white FIRE lettering cover with red FIRE lettering 1 8 in H x 5 in W x 1 1 2 in D 130 mm x 127 x 38 mm 5 Wire guards and ceiling mount chime strobe adapter mount red wire guard with mounting plate compatible with semi flush or surface boxes mount wire guard for mounting to flush mounted electrical adapter plate required to mount guard to surface electrical box mount adapter box use to cover 1 1 2 deep surface mounted 1 16 in H x 6 1 16 in W x 3 in D 154 mm x 154 mm 79 mm 1 2 in x 6 1 8 in x 3 in mm x 156 mm x 76 mm in x 7 in 229 mm x 178 3 4 in x 6 7 8 in x 1 1 2 in 121 mm x 175 mm x mm UL listed by Space Age Electronics 2 Rev 4 3 2021 Operation Audible Visible Notification with Chime and Synchronized Flash Non Addressable specifications voltage range rate and synchronized NAC loading temperature and humidity output characteristics see note 2 6 Wall mount or ceiling mount common specifications 24 DC see note 1 below Hz with up to 35 synchronized strobes maximum for each NAC to 122 0 to 50 10 to 93 non condensing at 100 38 blocks for 18 AWG to 12 AWG 0.82 mm to 3.31 mm two wires each terminal for in out wiring is adjustable from 750 Hz to 1300 Hz factory setting is approximately Hz output is adjustable from 34 dBA to 63 dBA factory setting is 63 dBA output ratings per UL 464 reverberant chamber test at 10 ft 3 m Regulated 24 DC refers to the voltage range of 16 to 33 VDC per UL Standard 1971 Signaling Devices for the Hearing Impaired This voltage range the absolute operating range Operation outside of this range may cause permanent damage to the appliance Please note that 16 VDC is the operating voltage that is allowed at the last appliance on the NAC under worst case conditions Factory settings are recommended for most applications Always test installed sound level against local requirements 7 Wall mount specifications dimensions with lens RMS current rating for strobe setting note RMS currents other voltages VDC VDC cd mA mA mA cd mA mA mA cd mA mA mA