Autocall SmartSync Operation Audible Visible Notification with Horn and Synchronized Flash, Non-Addressable
File Preview
Click below to download for free
Click below to download for free
File Data
Name | autocall-smartsync-operation-audible-visible-notification-with-horn-and-synchronized-flash-non-addressable-2734695180.pdf |
---|---|
Type | |
Size | 1.31 MB |
Downloads |
Text Preview
UL ULC CSFM Listed FM Multi Candela Notification Appliances Operation Audible Visible Notification with Horn and Synchronized Flash Non A V notification appliances with efficient horn and high output xenon strobe available for wall ceiling mount Operation is compatible with ADA requirements refer to important information on page 3 Rugged high impact flame retardant thermoplastic housings are in red or white with clear lens over a two wire SmartSync circuit to provide Horns that are controlled separately from strobes on the same two circuit rate On until silenced and on until reset operation on the same two wire SmartSync horn activation of Temporal pattern March Time pattern at BPM or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz Class B operation requires connection to a compatible SmartSync NAC to SmartSync Control Module SCM A4905 9938 Class A operation when connected to the A4905 9938 SCM or fire alarm control panel NACs mount A Vs features Wiring terminals are accessible from the front of the housing providing access for installation inspection and testing Covers are available separately to convert housing color Available UL listed sound damper for locations requiring attenuation of to 6 dBA stairwells small rooms highly reverberant areas etc adapters and wire guards Wall mount A V adapters are available to cover surface mounted boxes and to adapt to Autocall 2975 9145 boxes UL listed red wire guards are available for wall or ceiling mount A Vs notification appliance strobe 24 VDC xenon strobe intensity is selectable as 15 30 75 or 110 with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides inrush current notification appliance horn Low current 24 VDC electronic horn with harmonically rich sound suitable for either steady or coded operation Temporal or 60 March Time pattern UL listed to Standard 464 1 and Ceiling Mount A Vs TrueAlert A Vs with horn and synchronized strobe convenient installation to standard electrical boxes The designs are both impact and vandal resistant and provide a strobe intensity selection Since each model can be selected strobe intensity output on site model inventory is minimized and encountered during construction can be easily accommodated mount housings are a one piece assembly including lens that mounts to single or double gang or 4 square standard electrical box The cover be quickly removed a tool is required and covers are available for color conversion mount install using standard 4 electrical boxes Color choice is by model number Intensity Selection installation a selection plug at the back of the housing the desired strobe intensity An attached flag with black on a highly visible yellow background allows the selected intensity be seen at the side of the strobe lens Application Selection selection of visible notification is dependent on occupancy local codes and proper applications of the National Fire Alarm NFPA 72 ANSI A117.1 the appropriate model building code ICBO or SBCCI and the application guidelines of the Americans Disabilities Act ADA This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0532 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 8 03 2021 Operation Audible Visible Notification with Horn and Synchronized Flash Non Addressable Strobes Strobes When multiple strobes and their reflections can be seen from one location synchronized flashes reduce the probability of photo reactions as well as the annoyance and possible distraction of random flashing The multi candela strobes of these A Vs are synchronized by controlling SmartSync operation NAC Two Wire Control operation mode allows a two wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the to be silenced while the strobe remains flashing The horn operates as on until silenced while the strobe operation is on until reset Control Sources 4007ES Hybrid 4010ES and 4100ES Fire Alarm Control Panels refer to individual product data sheets for more information 4009 IDNet NAC Extender refer to data sheet AC4009 0002 SmartSync Control Module SCM A4905 9938 refer to data sheet AC4905 0003 SmartSync compatible notification appliances include separate horns and combination horn strobe notification appliances Selection 1 Multi Candela A Vs Color Lettering 2 Wall Mount A V Accessories Adapter Plate for mounting to 2975 9145 box typically for retrofit may be vertical or horizontal Mount Adapter Skirt use to cover 1 1 2 38 mm deep surface boxes Sound Damper package of 20 field installed adhesive backed horn output reduces output 5 to 6 dBA Sound Damper installation measure sound level to ensure compliance with code requirements 3 SmartSync Control Module Mounting Box requires Adapter Plate A4905 9931 with Multi Candela Strobe strobe intensity selectable as 15 30 75 110 candela operates with SmartSync two wire control H x 5 1 4 W x 1 5 8 D 136 mm x 133 x 41 mm depth with strobe 4 3 8 111 x 5 3 4 x 0.060 Thick 211 mm x 146 x 1.5 mm x 5 1 8 x 2 3 4 D 200 mm x 130 mm 70 mm Diameter 44.5 mm with 0.31 8 mm opening Control Module with Class B or Class A output mounts in 4 102 mm box refer to data sheet AC4905 0003 for details x 4 1 8 x 1 1 4 D 102 mm x 105 mm x 32 4 Replacement Covers for Wall Mount A Vs cover with white FIRE lettering cover with red FIRE lettering 5 Wire Guards and Ceiling Mount A V Adapter mount red wire guard with mounting plate compatible with semi flush or surface boxes Wire Guard for mounting to flush mounted electrical box Adapter Plate required to mount guard to surface mounted box Mount Adapter Box Extension use to cover 1 1 2 surface mounted boxes UL listed by Space Age Electronics Inc H x 5 W x 1 1 2 D 130 mm x 127 mm 38 mm H x 6 1 16 W x 3 1 8 D 154 mm x mm x 79 mm x 6 1 8 x 3 216 mm x 156 mm x 76 x 7 229 mm x 178 mm x 6 7 8 x 1 1 2 deep 121 mm x 175 x 38 mm 2 Rev 8 03 2021 Operation Audible Visible Notification with Horn and Synchronized Flash Non Addressable Specifications Voltage Range Listed Rating Listed Rating Rate and Synchronized NAC Loading Temperature and Humidity Output Characteristics Output ft 3 m see 2 Type See Note 2 464 Reverberant Chamber Chamber Dimensions with lens RMS Current Rating per Strobe see Note 3 below RMS Currents at voltages Dimensions with lens RMS Current Rating per Strobe see Note 3 below RMS Currents at voltages VDC VDC VDC VDC 6 Wall Mount or Ceiling Mount Common Specifications 24 DC see Note 1 below VDC to 30 VDC per ULC S526 M878 Hz with up to 35 synchronized strobes maximum per NAC to 122 F 0 to 50 C 10 to 93 non condensing at 100 F 38 C blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for wiring to 3700 Hz sweep modulated at 120 Hz rate VDC dBA dBA H x 5 W x 2 3 4 D 130 mm x 127 mm x 70 mm cd mA mA mA L x 6 7 8 W x 2 5 8 D 121 mm x 175 mm x 67 mm cd mA mA mA cd mA mA mA cd mA